This product, commonly called BHT, is commonly used as an antioxidant. It has a purity specification of at least 99.0 percent as determined by gas chromatography (GC), but it probably can also be used for HPLC work. If the BHT is in the eluant, it would be recommended to perform a blank run to identify any peaks coming from the BHT. And if the BHT is being added to the samples, it would be recommended to perform a sample blank run...with BHT, but without the analyte.
Select a Size
$38.70
$97.40
$38.70
Available to ship TODAYDetails
About This Item
Skip To
vapor density
7.6 (vs air)
Quality Level
vapor pressure
<0.01 mmHg ( 20 °C)
grade
purum
assay
≥99.0% (GC)
autoignition temp.
878 °F
bp
265 °C (lit.)
mp
68-72 °C
69-73 °C (lit.)
solubility
methanol: 0.1 g/mL, clear, colorless
methanol: soluble 100 mg/mL, clear, colorless
SMILES string
Cc1cc(c(O)c(c1)C(C)(C)C)C(C)(C)C
InChI
1S/C15H24O/c1-10-8-11(14(2,3)4)13(16)12(9-10)15(5,6)7/h8-9,16H,1-7H3
Inchi Key
NLZUEZXRPGMBCV-UHFFFAOYSA-N
Gene Information
human ... CAPN1(823)
rat ... Capn1(29153), Nos1(24598)
Looking for similar products? Visit Product Comparison Guide
1 of 4
This Item | W218405 | 8.17074 | PHR1117 |
|---|---|---|---|
| assay ≥99.0% (GC) | assay ≥99% | assay - | assay - |
| Quality Level 200 | Quality Level 400 | Quality Level 400 | Quality Level 300 |
| solubility methanol: 0.1 g/mL, clear, colorless, methanol: soluble 100 mg/mL, clear, colorless | solubility - | solubility - | solubility - |
| bp 265 °C (lit.) | bp 265 °C (lit.) | bp 265 °C/1013 hPa | bp 265 °C (lit.) |
| mp 68-72 °C, 69-73 °C (lit.) | mp 69-73 °C (lit.) | mp 69-70 °C | mp 69-73 °C (lit.) |
| vapor density 7.6 (vs air) | vapor density 7.6 (vs air) | vapor density - | vapor density 7.6 (vs air) |
General description
Application
signalword
Warning
hcodes
pcodes
Hazard Classifications
Aquatic Acute 1 - Aquatic Chronic 1
Storage Class
11 - Combustible Solids
wgk_germany
WGK 2
flash_point_f
260.6 °F - open cup
flash_point_c
127 °C - open cup
ppe
dust mask type N95 (US), Eyeshields, Gloves
Choose from one of the most recent versions:
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Articles
Simultaneous LC-MS/MS determination of vitamins D₂ and D₃ in infant milk powder meeting GB 5009.296-2023 criteria for accuracy and sensitivity.
-
Hi Can I use this for HPLC purpose as well. Using it as anti oxidant
1 answer-
Helpful?
-
Active Filters
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service