43843

Multielement Standard Solution 6 for ICP

TraceCERT®, 23 elements, 100 mg/L each in nitric acid and hydrofluoric acid

Synonym(s):

ICP Multi-Element Calibration Solution 6

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Pack SizeSKUAvailabilityPrice
100 mL
Check Cart for Availability
$230.00

About This Item

NACRES:
NA.24
UNSPSC Code:
41116107

$230.00


Check Cart for Availability

Request a Bulk Order
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


Quality Level

product line

TraceCERT®

grade

certified reference material, TraceCERT®

shelf life

limited shelf life, expiry date on the label

technique(s)

AAS: suitable, ICP: suitable

application(s)

industrial qc
pharmaceutical

format

multi-component solution

General description

This certified reference material (CRM) is produced in accordance with ISO 17034 and characterized in accordance with ISO/IEC 17025. This CRM is traceable to SI unit kg and measured against primary material from a National Metrology Institute (NMI), e.g. NIST.

Please visit ISO certificates and Site Quality Self-Assessments to access the current certificates of accreditation.

Search & download your certificate here.

Application

Multielement standard solution 6 can be used as a calibration standard in the:
  • Determination of trace metals in petroleum cokes using inductively coupled plasma optical emission spectrometry system (ICP-OES).
  • Trace metal analysis of seawater and fish otoliths via ICP-MS, enhancing the detection and quantification of trace metals critical in environmental samples.

Analysis Note

100 mg/L: Al, Sb, Ba, Pb, B, Ca, Cd, Cr, Co, Fe, K, Cu, Li, Mg, Mn, Mo, Na, Ni, P, Si, Ti, V, and Zn in 5% nitric acid and ≤0.1 % hydrofluoric acid.

Other Notes

For a complete product listing of our ICP and AAS range, including technical information and example certificates, please visit ICP & AAS standards website.

Detailed information on our complete workflow solutions for ICP-AAS can be found in our Brochure: High-Purity Chemicals for Inorganic Trace Analysis.

In our effort to be more sustainable, we′re going digital with COAs-download them directly from our website.

Legal Information

TraceCERT is a registered trademark of Merck KGaA, Darmstadt, Germany

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
547044959690243
grade

certified reference material, TraceCERT®

grade

certified reference material, TraceCERT®

grade

certified reference material, TraceCERT®

grade

certified reference material, TraceCERT®

technique(s)

AAS: suitable, ICP: suitable

technique(s)

ICP: suitable

technique(s)

ICP: suitable

technique(s)

ICP: suitable

format

multi-component solution

format

multi-component solution

format

multi-component solution

format

multi-component solution

product line

TraceCERT®

product line

TraceCERT®

product line

TraceCERT®

product line

TraceCERT®

application(s)

industrial qc
pharmaceutical

application(s)

industrial qc
pharmaceutical

application(s)

industrial qc
pharmaceutical

application(s)

industrial qc
pharmaceutical

shelf life

limited shelf life, expiry date on the label

shelf life

-

shelf life

-

shelf life

-


signalword

Danger

Hazard Classifications

Carc. 1B - Eye Dam. 1 - Met. Corr. 1 - Skin Corr. 1B - Skin Sens. 1

supp_hazards

wgk

WGK 3



Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library


Articles

ICP-MS workflow demonstrating the use of single- and multi-element standard mixes for accurate elemental analysis of lithium-ion battery cathode materials.





Global Trade Item Number

SKUGTIN
43843-100ML04061832178837

Questions

1–4 of 4 Questions  
  1. What form is the phosphorus in this solution? Is it phosphate complex ion?

    1 answer
    1. The phosphorus in this standard in the form of phosphate ion. The certified concentration is based on the phosphorous (P) content.

      Helpful?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  3. can you tell me the percent concentration of HF in this standard. I need to make sure it is compatible for use in systems that are running glass sample introduction systems. Is the HF at trace concentration to stabilize elements such as W, Si?

    1 answer
    1. The percent concentration of HF in this standard is less than 0.1%. The HF is included to dissolve silicon (Si) and is at a low concentration. However, it is suggested to test the compatibility for use in systems with glass sample introduction systems.

      Helpful?

  4. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters