MilliporeSigma
All Photos(1)

Documents

64004BC

Millipore

MVP ICON® Liquid Sampling Device

BioControl, ATP Liquid Sampling Swab for HACCP Management

Sign Into View Organizational & Contract Pricing

NACRES:
NB.79

Quality Level

form

liquid

packaging

box of 100 ea

manufacturer/tradename

BioControl Systems 64004-100

storage condition

protect from light (Sampling devices should be stored at a temperature between 2 ºC - 30 ºC (36 °F - 86 ºF). Protect from direct sunlight. Unused devices must be resealed in the foil bags.)

application(s)

cosmetics
food and beverages
industrial hygiene (monitoring)

compatibility

for use with MVP ICON instrument

detection method

bioluminescent

storage temp.

room temp

General description

The MVP ICON Liquid Sampling Device is a self-contained device for the analysis of liquid samples (i.e. rinse water) using the MVP ICON system. The MVP ICON system detects food and microbiological residue by measuring Adenosine triphosphate (ATP) using luciferase bioluminescence. ATP is found in most food residues and all bacteria, yeast and mold cells. The sample device features one-step, one-hand activation, freeing the other hand to perform other operations. All test reagents are contained within the sampling device.

Features and Benefits

Ease of Use
The MVP ICON ATP Liquid Sampling Device allows users to quickly collect and measure ATP content of liquid samples, such as CIP rinse water, directly from their source without pipetting or use of a sampling container.

Increased Accuracy and Repeatability
Upon activation, the proprietary test reagent flows through the hollow sampling device shaft to evenly wash ATP off sampling tip into bottom of the collection tube, ensuring a high degree of accuracy. The light output of the reagent solution is measured, not the solid device surface, ensuring a high degree of repeatability.

Convenient Storage
Store sampling devices at room temperature – no refrigeration needed; saving precious refrigeration space for other necessities.

Suitability

ATP Testing, Food Processing, HACCP Monitoring, Sanitation

Principle

The detection of ATP through bioluminescence is a well-established and widely used indicator of hygiene and cleaning efficacy in food processing. ATP detection with the MVP ICON provides results in 10 seconds allowing for immediate "go/no-go" decisions to be made prior to the start of processing and allows for correction actions, when necessary, to be taken immediately. ATP is a molecule that is found in all living cells, including: bacteria, yeast, mold and all organic matter.

Testing Method

ATP Bioluminescence

Legal Information

MVP ICON is a registered trademark of Merck KGaA, Darmstadt, Germany

Kit Components Also Available Separately

Product No.
Description
SDS

  • Wet Chamber

pictograms

Exclamation markEnvironment

signalword

Warning

Hazard Classifications

Aquatic Chronic 2 - Eye Irrit. 2 - Skin Irrit. 2 - Skin Sens. 1

Storage Class

10 - Combustible liquids

wgk_germany

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

Articles

Media fill tests for beverages ensure that the filling line is not contaminated with spoilage bacteria, yeasts, or molds, during the production of low-acid aseptic beverages.

Related Content

HACCP Disinfection control within the food & beverage industry is critical to ensure product safety and meet regulatory compliance. We offer an extensive range of products used in disinfection control and hygiene monitoring processes for food & beverage manufacturing.

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service