MilliporeSigma
All Photos(1)

PHR1552

Supelco

Chloroform

Pharmaceutical Secondary Standard; Certified Reference Material

Sign Into View Organizational & Contract Pricing

Select a Size

Synonym(s):
Chloroform, Methylidyne trichloride, Trichloromethane
Empirical Formula (Hill Notation):
CHCl3
CAS Number:
Molecular Weight:
119.38
Beilstein:
1731042
EC Number:
MDL number:
PubChem Substance ID:
NACRES:
NA.24

grade

certified reference material
pharmaceutical secondary standard

Quality Level

Agency

traceable to USP 1601383

vapor density

4.1 (vs air)

vapor pressure

160 mmHg ( 20 °C)

CofA

current certificate can be downloaded

packaging

ampule of 3x1.2 mL each

technique(s)

HPLC: suitable
gas chromatography (GC): suitable

refractive index

n20/D 1.445 (lit.)

bp

60.5-61.5 °C (lit.)

mp

−63 °C (lit.)

density

1.492 g/mL at 25 °C (lit.)

application(s)

pharmaceutical (small molecule)

format

neat

storage temp.

2-30°C

SMILES string

ClC(Cl)Cl

InChI

1S/CHCl3/c2-1(3)4/h1H

InChI key

HEDRZPFGACZZDS-UHFFFAOYSA-N

Looking for similar products? Visit Product Comparison Guide

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
C7559480150437581
Chloroform Pharmaceutical Secondary Standard; Certified Reference Material

Supelco

PHR1552

Chloroform

Chloroform ≥99%, PCR Reagent, contains amylenes as stabilizer

Sigma-Aldrich

C7559

Chloroform

Chloroform ACS reagent, ≥99.8%, contains amylenes as stabilizer

Sigma-Aldrich

480150

Chloroform

Chloroform ACS reagent, ≥99.8%, contains 0.5-1.0% ethanol as stabilizer

Sigma-Aldrich

437581

Chloroform

packaging

ampule of 3x1.2 mL each

packaging

vial of 1.5 mL

packaging

PVC-coated bottle of 4x4 L

packaging

PVC-coated bottle of 4x4 L

technique(s)

HPLC: suitable, gas chromatography (GC): suitable

technique(s)

PCR: suitable

technique(s)

-

technique(s)

-

application(s)

pharmaceutical (small molecule)

application(s)

-

application(s)

-

application(s)

-

format

neat

format

-

format

-

format

-

storage temp.

2-30°C

storage temp.

-

storage temp.

-

storage temp.

-

General description

Chloroform is a volatile chlorinated organic solvent whose vapors have a narcotic effect. It is a widely used industrial and laboratory solvent. It is also used in the manufacture of many pesticides, rubber, resin, and wax.
Pharmaceutical secondary standards for application in quality control, provide pharma laboratories and manufacturers with a convenient and cost-effective alternative to the preparation of in-house working standards.

Application

Chloroform may be used as a solvent reference standard for the determination of the analyte in bulk drug and dosage forms by spectrophotometry and spectrofluorimetry techniques.
These Secondary Standards are qualified as Certified Reference Materials. These are suitable for use in several analytical applications including but not limited to pharma release testing, pharma method development for qualitative and quantitative analyses, food and beverage quality control testing, and other calibration requirements.

Analysis Note

These secondary standards offer multi-traceability to the USP, EP and BP primary standards, where they are available.

Other Notes

This Certified Reference Material (CRM) is produced and certified in accordance with ISO 17034 and ISO/IEC 17025. All information regarding the use of this CRM can be found on the certificate of analysis.

Footnote

To see an example of a Certificate of Analysis for this material enter LRAA8822 in the slot below. This is an example certificate only and may not be the lot that you receive.

Recommended products

Find a digital Reference Material for this product available on our online platform ChemisTwin® for NMR. You can use this digital equivalent on ChemisTwin® for your sample identity confirmation and compound quantification (with digital external standard). An NMR spectrum of this substance can be viewed and an online comparison against your sample can be performed with a few mouseclicks. Learn more here and start your free trial.

Pictograms

Skull and crossbonesHealth hazard

Signal Word

Danger

Hazard Classifications

Acute Tox. 3 Inhalation - Acute Tox. 4 Oral - Carc. 2 - Eye Irrit. 2 - Repr. 2 - Skin Irrit. 2 - STOT RE 1 Oral - STOT SE 3

Target Organs

Respiratory system

Storage Class Code

6.1D - Non-combustible, acute toxic Cat.3 / toxic hazardous materials or hazardous materials causing chronic effects

WGK

WGK 3

Flash Point(F)

does not flash

Flash Point(C)

does not flash


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

Customers Also Viewed

Slide 1 of 7

1 of 7

Chloroform for analysis EMSURE® ACS,ISO,Reag. Ph Eur

Supelco

1.02445

Chloroform

Chloroform solution certified reference material, 5000 μg/mL in methanol

Supelco

40021

Chloroform solution

Chloroform for gas chromatography ECD and FID SupraSolv®

Supelco

1.02432

Chloroform

Acetone Pharmaceutical Secondary Standard; Certified Reference Material

Supelco

PHR1219

Acetone

Cyclohexane Pharmaceutical Secondary Standard; Certified Reference Material

Supelco

PHR1687

Cyclohexane

Chloroform HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%, contains amylenes as stabilizer

Sigma-Aldrich

650498

Chloroform

Chloroform HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%, contains 0.5-1.0% ethanol as stabilizer

Sigma-Aldrich

650471

Chloroform

Spectrophotometric and spectrofluorimetric determination of some drugs containing secondary amino group in bulk drug and dosage forms via derivatization with 7-chloro-4-nitrobenzofurazon
Onal A
Quimica nova, 34(4), 677-682 (2011)
Kuan Sun et al.
Nature communications, 6, 6013-6013 (2015-01-15)
Solution-processed organic photovoltaic cells (OPVs) hold great promise to enable roll-to-roll printing of environmentally friendly, mechanically flexible and cost-effective photovoltaic devices. Nevertheless, many high-performing systems show best power conversion efficiencies (PCEs) with a thin active layer (thickness is ~100 nm) that
Juyao Dong et al.
ACS nano, 8(5), 5199-5207 (2014-05-02)
The temperature increase inside mesoporous silica nanoparticles induced by encapsulated smaller superparamagnetic nanocrystals in an oscillating magnetic field is measured using a crystalline optical nanothermometer. The detection mechanism is based on the temperature-dependent intensity ratio of two luminescence bands in
Zhen Qi Lu et al.
Journal of proteome research, 13(12), 5869-5878 (2014-10-18)
In this study we carried out a mass spectrometry-based proteome analysis of human fetal atria and ventricles. Heart protein lysates were analyzed on the Q-Exactive mass spectrometer in biological triplicates. Protein identification using MaxQuant yielded a total of 2754 atrial
Mette Bohl et al.
The American journal of clinical nutrition, 101(4), 870-878 (2015-04-04)
Abdominal obesity and exaggerated postprandial lipemia are independent risk factors for cardiovascular disease (CVD) and mortality, and both are affected by dietary behavior. We investigated whether dietary supplementation with whey protein and medium-chain saturated fatty acids (MC-SFAs) improved postprandial lipid

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service