302031
3.9 (vs air)
97.5 mmHg ( 20 °C)
≥99.0%
liquid
HPLC: suitable
UV/Vis spectroscopy: suitable
<0.050% water
<0.005%
n20/D 1.3 (lit.)
1 (20 °C, 10 g/L)
72.4 °C (lit.)
−15.4 °C (lit.)
water: soluble
1.489 g/mL at 20 °C (lit.)
H2O reference
λ: 260 nm Amax: 0.9
λ: 270 nm Amax: 0.10
λ: 280 nm Amax: 0.05
λ: 290 nm Amax: 0.04
λ: 300 nm Amax: 0.03
λ: 320 nm Amax: 0.025
food and beverages
OC(C(F)(F)F)=O
1S/C2HF3O2/c3-2(4,5)1(6)7/h(H,6,7)
DTQVDTLACAAQTR-UHFFFAOYSA-N
Looking for similar products? Visit Product Comparison Guide
1 of 4
This Item | TX1276 | 91707 | T6508 |
---|---|---|---|
vapor pressure 97.5 mmHg ( 20 °C) | vapor pressure 97.5 mmHg ( 20 °C) | vapor pressure 97.5 mmHg ( 20 °C) | vapor pressure 97.5 mmHg ( 20 °C) |
assay ≥99.0% | assay ≥99.9% | assay ≥99.0% (GC) | assay 99% |
form liquid | form liquid | form liquid | form liquid |
impurities <0.050% water | impurities ≤0.05% Water | impurities ≤0.05% water | impurities ≤0.05% water |
refractive index n20/D 1.3 (lit.) | refractive index n20/D 1.3 (lit.) | refractive index n20/D 1.3 (lit.) | refractive index n20/D 1.3 (lit.) |
Danger
Acute Tox. 4 Inhalation - Aquatic Chronic 3 - Eye Dam. 1 - Skin Corr. 1A
8A - Combustible, corrosive hazardous materials
WGK 2
212.0 °F - Pensky-Martens closed cup
> 100 °C - Pensky-Martens closed cup
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.
How to Find the Product Number
Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (Example: T1503).
Example:
Additional examples:
705578-5MG-PW
PL860-CGA/SHF-1EA
MMYOMAG-74K-13
1000309185
enter as 1.000309185)
Having trouble? Feel free to contact Technical Service for assistance.
How to Find a Lot/Batch Number for COA
Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.
For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').
For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').
For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.
In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.
Optimization of a Reversed-Phase Liquid Chromatographic (RP-LC) method for the intact analysis of a therapeutic monoclonal antibody, trastuzumab, using a BIOshell™ A400 Protein C4 column.
Separation of L-Methionine, Pharmaceutical Secondary Standard; Certified Reference Material
This application note describes a step-by-step LC-UV-MS workflow for teriparatide peptide mapping, that includes enzymatic digestion, separation conditions, and their high resolution QTOF mass spectrometer based identification.
-casein basis (electrophoresis), lyophilized powder; β-Casein from bovine milk, BioUltra, ≥98% (PAGE)
Insulin is an approximately 6000 Da peptide hormone used to regulate the glucose concentration in blood. There are several different forms of insulin that are both natural and recombinant; the recombinant forms have been engineered to improve pharmacokinetic properties. A quick and reliable chromatographic technique was developed to identify and detect a mixture of insulin variants in an unknown sample.
HPLC Analysis of the Monoclonal Antibody (mAb) Erbitux (Cetuximab) on BIOshell™ A400 Protein C4
HPLC Analysis of Benzoic Acid Derivatives on Ascentis® C18
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service