GE17-5154-01

HiTrap® DEAE Fast Flow

Cytiva 17-5154-01, pack of 5 × 5 mL

NACRES:
NA.56

ligand

diethylaminoethyl

description

Ion Exchanger Type (value)

shelf life

Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.

packaging

pack of 5 × 5 mL

manufacturer/tradename

Cytiva 17-5154-01

parameter

<20 mL/min flow rate (The pressure over the packed bed varies depending on a range of parameters such as the characteristics of the chromatography medium and the column tubing used.)
42 psi

bed size

16 mm × 25 mm

bed volume

5 mL

column I.D.

16 mm

matrix

6% cross-linked agarose

particle size

45-165 μm

average diameter

90 μm

cleaning

2-14

working range

2-12

suitability

suitable for bioprocess medium

Related Categories

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
GE17-5055-01GE17-5157-01GE17-5156-01
HiTrap&#174; DEAE Fast Flow Cytiva 17-5154-01, pack of 5 × 5&#160;mL

GE17-5154-01

HiTrap® DEAE Fast Flow

HiTrap&#174; DEAE Fast Flow Cytiva 17-5055-01, pack of 5 × 1&#160;mL

GE17-5055-01

HiTrap® DEAE Fast Flow

HiTrap&#174; SP Fast Flow Cytiva 17-5157-01, pack of 5 × 5&#160;mL

GE17-5157-01

HiTrap® SP Fast Flow

HiTrap&#174; Q Fast Flow Cytiva 17-5156-01, pack of 5 × 5&#160;mL

GE17-5156-01

HiTrap® Q Fast Flow

matrix

6% cross-linked agarose

matrix

6% cross-linked agarose

matrix

6% cross-linked agarose

matrix

6% cross-linked agarose

particle size

45-165 μm

particle size

45-165 μm

particle size

45-165 μm

particle size

45-165 μm

ligand

diethylaminoethyl

ligand

diethylaminoethyl

ligand

sulphopropyl

ligand

quaternary amine

description

Ion Exchanger Type (value)

description

Ion Exchanger Type (value)

description

Ion Exchanger Type (value)

description

Ion Exchanger Type (value)

shelf life

Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.

shelf life

Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.

shelf life

Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.

shelf life

Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.

General description

HiTrap® DEAE FF is prepacked with DEAE Sepharose Fast Flow, and is a weak anion exchanger for small-scale protein purifications as well as screening of binding and elutions conditions.

Q, SP, DEAE, and CM Sepharose Fast Flow are based on a robust, 6% highly cross-linked beaded agarose matrix with good flow properties and high loading capacities. ANX Sepharose 4 Fast Flow (high sub) is based on 4% highly cross-linked beaded agarose. This results in a medium with higher porosity, which is particularly useful for the purification of high molecular mass proteins.

The active end of the charged group is the same for DEAE Sepharose Fast Flow and ANX Sepharose Fast Flow (high sub), the difference is the length of the carbon chain of the charged group. DEAE Sepharose Fast Flow has a diethylaminoethyl-group bound to the agarose whilst ANX Sepharose 4 Fast Flow (high sub) has a diethylaminopropyl group attached.

Features and Benefits

  • Convenient and affordable for fast, easy ion exchange separations either alone or connected in series.
  • The industry standard for ion exchange chromatography.
  • High flow rates and good scale-up potential.
  • Use a weak ion exchanger if the selectivity of a strong ion exchanger is insufficient.
  • Predictable scale-up

Storage and Stability

Store at 4 to 30 °C (20% Ethanol)

Analysis Note

To view the Certificate of Analysis for this product, please visit www.cytiva.com.

Legal Information

HiTrap is a registered trademark of Cytiva
Sepharose is a trademark of Cytiva

Pictograms

Flame

Signal Word

Warning

Hazard Statements

Storage Class Code

3 - Flammable liquids


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (Example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

Customers Also Viewed

Slide 1 of 10

1 of 10

HiTrap&#174; Q Fast Flow Cytiva 17-5053-01, pack of 5 × 1&#160;mL

GE17-5053-01

HiTrap® Q Fast Flow

HiPrep&#8482; CM Fast Flow 16/10 Cytiva 28-9365-42

GE28-9365-42

HiPrep CM Fast Flow 16/10

HiTrap&#174; IEX Selection Kit Cytiva 17-6002-33

GE17-6002-33

HiTrap® IEX Selection Kit

DEAE–Sepharose&#8482; CL-6B

Sigma-Aldrich

DCL6B100

DEAE–Sepharose

HiTrap&#174; Q High Performance Cytiva 17-1154-01, pack of 5 × 5&#160;mL

GE17-1154-01

HiTrap® Q High Performance

HiTrap&#174; Q XL Cytiva 17-5159-01, pack of 5 × 5&#160;mL

GE17-5159-01

HiTrap® Q XL

DEAE-Sepharose&#8482; CL-6B Cytiva 17-0710-01, pack of 500&#160;mL

GE17-0710-01

DEAE-Sepharose CL-6B

HiTrap&#174; SP HP Cytiva 29-0513-24, pack of 1&#160;mL

GE29-0513-24

HiTrap® SP HP

Articles

Purification of Membrane Proteins

This page shows how to perform a purification of His-tagged membrane proteins.

Selection of Purification Equipment

This page covers the standard ÄKTAdesign configurations for simple IEX chromatography.

Non-volatile and Volatile Buffer Systems

This page shows volatile and non-volatile buffer suggestions for anion and cation exchange chromatography.

Ion Exchange Chromatography Troubleshooting

This page covers practical problems that may lead to a non-ideal IEX separation and their solutions.

See All

Protocols

Sepharose Fast Flow: Purification with Good Resolution and Easy Scale-Up

This page covers the use of Sepharose Fast Flow for purification of proteins.

Column packing and preparation for Ion Exchange Chromatography & Chromatafocusing

This page shows how to perform column packing and preparation for ion exchange chromatography and chromatafocusing when using Tricorn or XK columns available from Cytiva.

Sample Preparation in Ion Exchange Chromatography

This page clarifies sample preparation, buffer exchange and desalting, removal of lipoproteins, phenol red, and low molecular weight contaminants in Ion exchange chromatography.

Column Cleaning for Ion Exchange Chromatography and Chromatofocusing

This page covers detailed information on cleaning procedures and recommended flow for column cleaning.

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service