Skip to Content
MilliporeSigma

Skip To

MAK113

ATPase/GTPase Activity Assay Kit

sufficient for 200 colorimetric tests

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Pack SizeSKUAvailabilityPrice
1 kit
Check Cart for Availability
$576.00

About This Item

NACRES:
NA.84
UNSPSC Code:
12161503

$576.00


Check Cart for Availability

Request a Bulk Order
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


usage

sufficient for 200 colorimetric tests

packaging

pkg of 1 kit

storage condition

dry at room temperature

technique(s)

activity assay: suitable

input

liquid

detection method

colorimetric

relevant disease(s)

cancer

storage temp.

2-8°C

General description

ATPases and GTPases catalyze the decomposition of ATP or GTP into ADP or GDP and free phosphate. These enzymes play key roles in transport, signal transduction, protein biosynthesis, and cell differentiation.

Application

ATPase/GTPase Activity Assay Kit has been used to measure the ATPase enzyme activity in:
  • Dicer-like 1 (DCL1) and its mutants, to terminate the reaction and generate a colorimetric product[1]
  • various brain regions of mice, facilitating the quantification of inorganic phosphate released from ATP[2]
  • cell lysates, for the development and encapsulation of the reconstituted cell-free enzyme system
Suitable for the detection of ATPase and GTPase activity and for the screening of ATPase and GTPase inhibitors.

Biochem/physiol Actions

The ATPase/GTPase Activity Assay kit provides a simple and direct procedure for measuring ATPase/GTPase activity in a microplate format. This kit uses a single reagent formulation to accurately determine enzyme activity in 30 minutes at room temperature. The malachite green reagent forms a stable dark green color with free phosphate liberated by the enzymes resulting in a colorimetric product, measured at 620 nm (600-660 nm), proportional to the enzyme activity present One unit of activity is the amount of enzyme that catalyzes the production of 1 μmole of free phosphate per minute under the assay conditions.

Features and Benefits

Compatible with high-throughput handling systems.

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
MAK120MAK123MAK109
detection method

colorimetric

detection method

colorimetric

detection method

colorimetric

detection method

fluorometric

technique(s)

activity assay: suitable

technique(s)

-

technique(s)

-

technique(s)

-

usage

sufficient for 200 colorimetric tests

usage

sufficient for 100 colorimetric tests

usage

sufficient for 100 colorimetric tests

usage

sufficient for 100 fluorometric tests

storage temp.

2-8°C

storage temp.

2-8°C

storage temp.

−20°C

storage temp.

2-8°C

storage condition

dry at room temperature

storage condition

-

storage condition

-

storage condition

-

input

liquid

input

-

input

-

input

-


pictograms

Corrosion

signalword

Warning

hcodes

Hazard Classifications

Met. Corr. 1

flash_point_f

Not applicable

flash_point_c

Not applicable

wgk

WGK 2

Storage Class

12 - Non Combustible Liquids



Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library



Meng-Yan Sun et al.
Oncology reports, 39(6), 2673-2680 (2018-04-06)
Regulator of G‑protein signaling 1 (RGS1) has been found to be a critical factor in melanoma and other malignancies. However, the mechanism involved in the RGS1‑mediated promotion of melanoma progression is not clear. We based our study on samples collected from
Emilie Mahieu et al.
Biophysical journal, 119(2), 375-388 (2020-07-09)
The proteasome is a key player of regulated protein degradation in all kingdoms of life. Although recent atomic structures have provided snapshots on a number of conformations, data on substrate states and populations during the active degradation process in solution
Shuhui Wang et al.
Protein & cell, 11(2), 124-137 (2019-11-24)
Type VII secretion systems (T7SSs) are found in many disease related bacteria including Mycobacterium tuberculosis (Mtb). ESX-1 [early secreted antigen 6 kilodaltons (ESAT-6) system 1] is one of the five subtypes (ESX-1~5) of T7SSs in Mtb, where it delivers virulence



Global Trade Item Number

SKUGTIN
MAK113-1KT04061834065364

Questions

1–6 of 6 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  3. Is the MAK113 ATPase/GTPase Activity Assay Kit compatible in both acidic and basic pH environments? Within what pH range is this assay compatible? I am attempting to measure the GTPase activity within a pH range of 5.5 - 8.0.

    1 answer
    1. As per the guidance, the assay has been optimized with Assay Buffer at pH 7.5. It's important to note that the assay is pH dependent, and the enzymatic reaction is stopped by adding an acidic reagent. With the samples themselves expected to be largely neutralized by the assay buffer, they should be suitable within the pH range of 5.5 to 8. However, it is not advisable to prepare a different buffer to test the reaction under more acidic conditions. There is a possibility that conducting the reaction under more acidic conditions, like pH 5.5, might inhibit enzyme activity.

      Helpful?

  4. Does malachite green react with phosphate molecules in which one oxygen is substituted by sulfur when using GTPgammaS instead of GTP to detect RAN GTPase activity? Additionally, could malachite green turn blue in reaction with other molecules besides phosphate?

    1 answer
    1. Unfortunately, it has not been tested whether malachite green also reacts with phosphate molecules in which one oxygen is substituted with sulfur, and there is uncertainty about other molecules that could cause a blue color change. It is also possible that there might be contaminating free phosphate in the materials used for the assay. The datasheet for the kit contains instructions on how to check for any contaminating free phosphate.

      Helpful?

  5. Would storage of the MAK113 ATPase/GTPase Activity Assay Kit at -20°C for 4 days affect its performance?

    1 answer
    1. Based on available information, it is not expected that storage at -20°C would significantly affect the kit’s performance or shelf life.

      Helpful?

  6. What is the detailed composition of Malachite Green Reagent (MAK 113A) in the ATPase/GTPase Activity Assay Kit (MAK113)?

    1 answer
    1. A detailed composition of the reagent is not available as this is considered proprietary information.

      Helpful?

Reviews

No rating value

Active Filters