MilliporeSigma
All Photos(2)

24136

Supelco

Omegawax Capillary GC Column

L × I.D. 30 m × 0.25 mm, df 0.25 μm

eCl@ss:
32119290

material

fused silica

Quality Level

Agency

meets requirements for USP G16

parameter

50-280 °C temperature (isothermal or programmed)

Beta value

250

df

0.25 μm

technique(s)

gas chromatography (GC): suitable

L × I.D.

30 m × 0.25 mm

matrix active group

Bonded; poly(ethylene glycol) phase

application(s)

agriculture
biofuels
clinical
food and beverages

column type

capillary polar

Looking for similar products? Visit Product Comparison Guide

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
2415223399-U24284
agency

meets requirements for USP G16

agency

meets requirements for USP G16

agency

meets requirements for USP G16

agency

OSHA 52,80, meets requirements for USP G16

parameter

50-280 °C temperature (isothermal or programmed)

parameter

50-280 °C temperature (isothermal or programmed)

parameter

50-280 °C temperature (isothermal or programmed)

parameter

35-280 °C temperature (isothermal or programmed)

df

0.25 μm

df

0.25 μm

df

0.10 μm

df

0.50 μm

technique(s)

gas chromatography (GC): suitable

technique(s)

gas chromatography (GC): suitable

technique(s)

gas chromatography (GC): suitable (fast GC)

technique(s)

gas chromatography (GC): suitable

matrix active group

Bonded; poly(ethylene glycol) phase

matrix active group

Bonded; poly(ethylene glycol) phase

matrix active group

Bonded; poly(ethylene glycol) phase

matrix active group

Bonded; poly(ethylene glycol) phase

General description

Application: This column allows highly reproducible analyses of fatty acid methyl esters (FAMEs), specifically the omega 3 and omega 6 fatty acids. It is tested to ensure reproducible FAME equivalent chain length (ECL) values and resolution of key components.
USP Code: This column meets USP G16 requirements.
Phase:
  • Bonded
  • Poly(ethylene glycol)
Temp. Limits:
  • 50 °C to 280 °C (isothermal or programmed)

Application

Capillary GC column with its coated with Omegawax 250 was used for the absorption of analytes from the aqueous sample in-tube solid-phase microextraction coupled with high-performance liquid chromatography. It may also be used in blood lipid fractions by GC-MS analysis.

Other Notes

We offer a variety of chromatography accessories including analytical syringes

Legal Information

Omegawax is a trademark of Sigma-Aldrich Co. LLC

Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (Example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

Customers Also Viewed

Slide 1 of 4

1 of 4

Automated in-tube solid-phase microextraction coupled to high-performance liquid chromatography.
Ralf E and Pawliszyn J.
Analytical Chemistry, 69 (16), 3140-3147 (1997)
R O Adlof et al.
Lipids, 35(2), 131-135 (2000-04-11)
This paper deals with the reanalysis of serum lipids from previous studies in which deuterated fatty acids were administered to a single person. Samples were reanalyzed to determine if the deuterated fatty acids were converted to deuterium-labeled conjugated linoleic acid
Susana P Alves et al.
Journal of chromatography. A, 1216(26), 5130-5139 (2009-05-19)
Two gas-liquid chromatograph capillary columns for the analysis of fatty acids (FA) in ruminant fat are compared. Those columns are the CP-Sil 88 of 100 m long with a highly polar stationary phase and the Omegawax 250 of 30 m
M Vecka et al.
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, 770(1-2), 91-99 (2002-05-16)
Four capillary columns (A: CP-WAX 52 CB 25 m x 0.25 mm; B: CP WAX 52 CB 30 m x 0.25 mm; C: CP-WAX 58 CB 25 m x 0.25 mm, Chrompack; D: OMEGAWAX 320 30 m x 0.32 mm
H Kataoka et al.
Analytical chemistry, 71(19), 4237-4244 (1999-10-12)
The technique of automated in-tube solid-phase microextraction (SPME) coupled with liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) was evaluated for the determination of beta-blockers in urine and serum samples. In-tube SPME is an extraction technique for organic compounds in aqueous samples

Articles

GC Analysis of a 37-Component FAME Mix on Omegawax®

This technical article will discuss GC Analysis of a 37-Component FAME Mix on Omegawax.

Protocols

GC Analysis of Fatty Acids in Walnuts and Peanuts

Determination of the fatty acid composition of nuts using established methods for GC analysis on capillary columns of 3 selectivities: Omegawax, SP-2560, and ionic liquid based SLB-IL111.

GC Analysis of Omega 3 Fatty Acids in Fish Oil Capsules and Farm Raised Salmon

nalysis of the omega 3 fatty acid profiles from fish oil capsules and salmon, highlighted through the use of 2 GC columns of different selectivity for analysts who wish to perform confirmatory analysis.

GC Analysis of Volatiles in Roasted Coffee Beans on Omegawax® after SPME using a 50/30 µm DVB/Carboxen/PDMS Fiber

-Cymene; 2,5-Dimethylpyrrole; Acetoin, ≥96%, FCC, FG; 2,5-Dimethylpyrazine; 2,6-Dimethylpyrazine; 2-Ethylpyrazine, ≥98%, FG; 2,3-Dimethylpyrazine; 4-Heptanone; 3-Ethylpyridine; 2,3,5-Trimethylpyrazine; Furfural; Pyrrole; Furfuryl acetate; Linalool; Linalyl acetate; 5-Methylfurfural; γ-Butyrolactone; 2-Acetyl-1-methylpyrrole; Furfuryl alcohol; 2-Acetylpyrrole; Pyrrole-2-carboxaldehyde

Chromatograms

application for SPME, suitable for GCsuitable for GCsuitable for GCsuitable for GCShow More

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service