Skip to Content
MilliporeSigma

Skip To

28465-U

SLB®-5ms Capillary GC Column

L × I.D. 10 m × 0.10 mm, df 0.10 μm

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Size/SKUAvailabilityPrice
1 ea

Available to ship TODAYfromMILWAUKEE

$659.00
$494.25

About This Item

UNSPSC Code:
41115710
NACRES:
SB.54
eCl@ss:
32119290

$494.25

List Price$659.00Save 25%
Web-Only Promotion

Available to ship TODAYDetails


Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


material

fused silica

Quality Segment

agency

Standard Method 6040D, EN 2005/108/EC, EPA 610,625,8015,8082,8100,8141,8270,OLM04.2 SVOA, EPA TO-13,IP-8,8270,525.2,608.1/608.2,608/8081/OLM04.2 PEST, JMHLW, NIOSH 2530,5503, OSHA 62, meets requirements for USP G27 and G36, suitable for EPA 1613

reg. compliance

FDA LIB 4423

analyte chemical class(es)

PAHs, PCBs, alcohols, amino acids, amphetamines, bacterial acid methyl esters (BAMEs), barbiturates, dioxins, estrogens, fatty acid ethyl esters (FAEEs), furans, hopanes (triterpenes), ketones, nitrosamines, organic acids, phenothiazines, phthalate esters, steroids, terpenes, tryptamines

specific analyte(s)

3-MCPD

parameter

-60-340 °C temperature (isothermal), -60-360 °C temperature (programmed)

Beta value

250

df

0.10 μm

technique(s)

GC/MS: suitable, gas chromatography (GC): suitable (fast GC)

L × I.D.

10 m × 0.10 mm

matrix active group

Bonded and highly crosslinked; silphenylene polymer virtually equivalent in polarity to poly(5% diphenyl/95% dimethyl siloxane) phase, SLB 5ms

application(s)

agriculture
chemicals and industrial polymers
cleaning products
clinical
cosmetics
environmental
flavors and fragrances
food and beverages
forensics and toxicology
industrial hygiene
life science and biopharma
personal care
petroleum
pharmaceutical (small molecule)

column type

capillary non-polar

General description

Application: The 5% phenyl equivalent phase provides a boiling point elution order with a slight increase in selectivity, especially for aromatic compounds. The low bleed characteristics, inertness, and durable nature make it the column of choice for environmental analytes (such as semivolatiles, pesticides, PCBs, and herbicides) or anywhere a low bleed non-polar column is required.
USP Code: This column meets USP G27 and G36 requirements.
Phase:
  • Bonded and highly crosslinked
  • Silphenylene polymer virtually equivalent in polarity to poly(5% diphenyl/95% dimethyl siloxane)
Temp. Limits:
  • ≤0.32 mm I.D.: -60 °C to 340 °C (isothermal) or 360 °C (programmed)
  • ≥0.53 mm I.D.: -60 °C to 330 °C (isothermal) or 340 °C (programmed)

Other Notes

We offer a variety of chromatography accessories including analytical syringes

Legal Information

SLB is a registered trademark of Merck KGaA, Darmstadt, Germany

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
28564-U28482-U28467-U
matrix active group

Bonded and highly crosslinked; silphenylene polymer virtually equivalent in polarity to poly(5% diphenyl/95% dimethyl siloxane) phase, SLB 5ms

matrix active group

Bonded and highly crosslinked; silphenylene polymer virtually equivalent in polarity to poly(5% diphenyl/95% dimethyl siloxane) phase, SLB 5ms

matrix active group

Bonded and highly crosslinked; silphenylene polymer virtually equivalent in polarity to poly(5% diphenyl/95% dimethyl siloxane) phase, SLB 5ms

matrix active group

Bonded and highly crosslinked; silphenylene polymer virtually equivalent in polarity to poly(5% diphenyl/95% dimethyl siloxane) phase, SLB 5ms

parameter

-60-340 °C temperature (isothermal), -60-360 °C temperature (programmed)

parameter

-60-340 °C temperature (isothermal), -60-360 °C temperature (programmed)

parameter

-60-340 °C temperature (isothermal), -60-360 °C temperature (programmed)

parameter

-60-340 °C temperature (isothermal), -60-360 °C temperature (programmed)

application(s)

agriculture
chemicals and industrial polymers
cleaning products
clinical
cosmetics
environmental
flavors and fragrances
food and beverages
forensics and toxicology
industrial hygiene
life science and biopharma
personal care
petroleum
pharmaceutical (small molecule)

application(s)

agriculture
chemicals and industrial polymers
cleaning products
clinical
cosmetics
environmental
flavors and fragrances
food and beverages
forensics and toxicology
industrial hygiene
life science and biopharma
personal care
petroleum
pharmaceutical (small molecule)

application(s)

agriculture
chemicals and industrial polymers
cleaning products
clinical
cosmetics
environmental
flavors and fragrances
food and beverages
forensics and toxicology
industrial hygiene
life science and biopharma
personal care
petroleum
pharmaceutical (small molecule)

application(s)

agriculture
chemicals and industrial polymers
cleaning products
clinical
cosmetics
environmental
flavors and fragrances
food and beverages
forensics and toxicology
industrial hygiene
life science and biopharma
personal care
petroleum
pharmaceutical (small molecule)

material

fused silica

material

fused silica

material

fused silica

material

fused silica

column type

capillary non-polar

column type

capillary non-polar

column type

capillary non-polar

column type

capillary non-polar

technique(s)

GC/MS: suitable, gas chromatography (GC): suitable (fast GC)

technique(s)

GC/MS: suitable, gas chromatography (GC): suitable (fast GC)

technique(s)

GC/MS: suitable, gas chromatography (GC): suitable

technique(s)

GC/MS: suitable, gas chromatography (GC): suitable


Still not finding the right product?

Explore all of our products under SLB®-5ms Capillary GC Column




Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documents section.

If you need assistance, please contact Customer Support

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library



Questions

1–6 of 6 Questions  
  1. What if my method does not allow me to change to SLB™-5ms Capillary GC Columns?

    1 answer
    1. These methods typically specify a 5-type column (DB-5 or equivalent). The SLB-5ms satisfies that requirement.

      Helpful?

  2. Would you recommend SLB™-5ms Capillary GC Columns for all applications instead of Equity-5, SPB-5, PTE-5, MDN-5, and MDN-5S?

    1 answer
    1. Yes.

      Helpful?

  3. What are the benefits of the SLB™-5ms Capillary GC Column over other manufacturers’ -5ms columns?

    1 answer
    1. The SLB-5ms excels in several performance criteria.· Low Bleed. The highly crosslinked silphenylene polymer chemistry reduces column bleed to a very low level, resulting in greater signal-to-noise level, allowing lower detection levels.· Inertness. The proprietary surface deactivation reduces interactions between analytes and the column surface, resulting in sharper peak shapes, allowing lower detection levels.· Durability. With the highest published maximum allowable operating temperature (MAOT) of any -5ms column, SLB-5ms columns are designed for long life.· Consistency. Innovative manufacturing processes result in decreased column variability, ensuring that the next column is as good as the last.

      Helpful?

  4. Who uses SLB™-5ms Capillary GC Columns?

    1 answer
    1. Any analyst with the need for a non-polar column. Some applications include boiling point separations, GC-MS analyses of semivolatiles, and GC-ECD analyses of pesticides/PCBs. It is estimated that non-polar columns account for 51% of the worldwide column market.

      Helpful?

  5. How does the SLB™-5ms Capillary GC Column differ from our other 5-type columns?

    1 answer
    1. Many of our other 5-type columns (Equity-5, SPB-5, PTE-5, MDN-5, and MDN-5S) incorporate a siloxane polymer (backbone comprised of Si and O atoms only, side groups are either methyl or phenyl). The SLB-5ms column incorporates a silphenylene polymer (backbone comprised of Si and O atoms plus some phenyl groups, side groups are either methyl or phenyl).

      Helpful?

  6. What is the Department of Transportation shipping information for this product?

    1 answer
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      Helpful?

Reviews

No rating value

Active Filters