Select a Size
| Size/SKU | Availability | Price |
|---|---|---|
10 ea | Estimated to ship onAugust 07, 2026fromMILWAUKEE | $285.00 $242.25 |
About This Item
$242.25
List Price$285.00Save 15%Estimated to ship onAugust 07, 2026Details
Product Name
5L Tedlar® SCV Gas Sampling Bag w/Thermogreen® LB-2 Septa,
material
Tedlar® PVDF film
Quality Segment
agency
suitable for ASTM® D5504 (Sulfur Compounds in Natural Gas and Fuels by GC), suitable for EPA 18 (Gaseous Organic Compounds; VOCs by GC), suitable for EPA 40,TO-3,TO-15 (Volatile Organic Compounds (VOCs)), suitable for EPA TO-12 (Non-Methane Organic Compounds (NMOC)), suitable for EPA TO-14A (Volatile Organic Compounds (VOCs) by GC/MS), suitable for NIOSH 3704 (Perchloroethylene)
description
Screw Cap Valve (SCV), septum type: yes; Thermogreen® LB-2
packaging
pkg of 10 bags
technique(s)
whole air sampling: suitable
W × L
12 in. × 14 in.
maximum volume
5 L
application(s)
air monitoring
environmental
industrial hygiene
compatibility
for use with Calibration mixes - gas phase standards/gas mixtures
General description
Application
- Preservation of exhaled breath samples for analysis by off-line SESI-HRMS: Demonstrates the utility of 5L Tedlar® SCV Gas Sampling Bags in preserving breath samples for secondary electrospray ionization-high resolution mass spectrometry, enhancing diagnostic capabilities in medical research (Sola-Martínez et al., 2023).
- Quantitative GC-TCD Measurements of Major Flatus Components: Utilizes 5L Tedlar® SCV Gas Sampling Bags for gas chromatography with a thermal conductivity detector to study dietary effects on flatus composition, contributing to better understanding of digestive processes (Freire et al., 2022).
- Quantification of volatile organic compounds by secondary electrospray ionization-high resolution mass spectrometry: Highlights the role of 5L Tedlar® SCV Gas Sampling Bags in the capture and quantification of volatile organic compounds, critical for environmental and chemical analysis (Liu et al., 2021).
- Application of a Microfluidic Gas-to-Liquid Interface for Extraction of Target Amphetamines and Precursors from Air Samples: Details the use of 5L Tedlar® SCV Gas Sampling Bags in microfluidic systems for precise air sampling and extraction, aiding forensic and environmental studies (Collins et al., 2020).
- Determination of linear and cyclic volatile methyl siloxanes in biogas and biomethane by solid-phase microextraction and gas chromatography-mass spectrometry: Discusses the effectiveness of 5L Tedlar® SCV Gas Sampling Bags in sampling for the analysis of complex gas mixtures, important for environmental monitoring and biogas quality control (Ghidotti et al., 2019).
Legal Information
1 of 1
This Item | |||
|---|---|---|---|
| material Tedlar® PVDF film | material Tedlar® PVDF film | material Tedlar® PVDF , Tedlar® PVDF film | material Tedlar® PVDF film |
| agency suitable for ASTM® D5504 (Sulfur Compounds in Natural Gas and Fuels by GC), suitable for EPA 40,TO-3,TO-15 (Volatile Organic Compounds (VOCs)), suitable for EPA TO-14A (Volatile Organic Compounds (VOCs) by GC/MS), suitable for EPA 18 (Gaseous Organic Compounds; VOCs by GC), suitable for NIOSH 3704 (Perchloroethylene), suitable for EPA TO-12 (Non-Methane Organic Compounds (NMOC)) | agency suitable for ASTM® D5504 (Sulfur Compounds in Natural Gas and Fuels by GC), suitable for EPA 18 (Gaseous Organic Compounds; VOCs by GC), suitable for EPA 40,TO-3,TO-15 (Volatile Organic Compounds (VOCs)), suitable for EPA TO-12 (Non-Methane Organic Compounds (NMOC)), suitable for EPA TO-14A (Volatile Organic Compounds (VOCs) by GC/MS), suitable for NIOSH 3704 (Perchloroethylene) | agency suitable for ASTM® D5504 (Sulfur Compounds in Natural Gas and Fuels by GC), suitable for EPA 18 (Gaseous Organic Compounds; VOCs by GC), suitable for EPA 40,TO-3,TO-15 (Volatile Organic Compounds (VOCs)), suitable for EPA TO-12 (Non-Methane Organic Compounds (NMOC)), suitable for EPA TO-14A (Volatile Organic Compounds (VOCs) by GC/MS), suitable for NIOSH 3704 (Perchloroethylene) | agency suitable for ASTM® D5504 (Sulfur Compounds in Natural Gas and Fuels by GC), suitable for EPA 18 (Gaseous Organic Compounds; VOCs by GC), suitable for EPA 40,TO-3,TO-15 (Volatile Organic Compounds (VOCs)), suitable for EPA TO-12 (Non-Methane Organic Compounds (NMOC)), suitable for EPA TO-14A (Volatile Organic Compounds (VOCs) by GC/MS), suitable for NIOSH 3704 (Perchloroethylene) |
| technique(s) whole air sampling: suitable | technique(s) whole air sampling: suitable | technique(s) whole air sampling: suitable | technique(s) whole air sampling: suitable |
| packaging pkg of 10 bags | packaging pkg of 10 bags | packaging pkg of 5 ea | packaging pkg of 10 bags |
| Quality Level 100 | Quality Level 100 | Quality Level - | Quality Level 100 |
| application(s) air monitoring | application(s) air monitoring | application(s) air monitoring | application(s) air monitoring |
Still not finding the right product?
Explore all of our products under 5L Tedlar® SCV Gas Sampling Bag w/Thermogreen® LB-2 Septa
Choose from one of the most recent versions:
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.