Ascentis® Express HILIC, 5 μm Guard Cartridge, 5 μm particle size, L × I.D. 5 mm × 4.6 mm, pkg of 3 ea
material
stainless steel column
Quality Level
agency
suitable for USP L3
product line
Ascentis®
feature
endcapped: no
packaging
pkg of 3 ea
technique(s)
HPLC: suitable
LC/MS: suitable
L × I.D.
5 mm × 4.6 mm
surface area
90 m2/g
matrix
superficially porous particle
matrix active group
silica phase
particle size
5 μm
pore size
90 Å
operating pH
1-8
application(s)
food and beverages
separation technique
hydrophilic interaction (HILIC)
normal phase
Looking for similar products? Visit Product Comparison Guide
Related Categories
1 of 4
This Item | 50295-U | 50297-U | 51433-U |
|---|---|---|---|
| L × I.D. 5 mm × 4.6 mm | L × I.D. 5 mm × 2.1 mm | L × I.D. 5 mm × 3 mm | L × I.D. 5 mm × 3 mm |
| matrix active group silica phase | matrix active group silica phase | matrix active group silica phase | matrix active group silica phase |
| particle size 5 μm | particle size 5 μm | particle size 5 μm | particle size 2 μm |
| separation technique hydrophilic interaction (HILIC), normal phase | separation technique hydrophilic interaction (HILIC), normal phase | separation technique hydrophilic interaction (HILIC), normal phase | separation technique hydrophilic interaction (HILIC), normal phase |
| product line Ascentis® | product line Ascentis® | product line Ascentis® | product line Ascentis® |
| agency suitable for USP L3 | agency suitable for USP L3 | agency suitable for USP L3 | agency suitable for USP L3 |
General description
Legal Information
used together
Storage Class
11 - Combustible Solids
wgk_germany
WGK 3
flash_point_f
Not applicable
flash_point_c
Not applicable
Choose from one of the most recent versions:
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
-
What is the Department of Transportation shipping information for this product?
1 answer-
Helpful?
-
-
What steps should be taken to maximize column life?
1 answer-
To maximize column life, ensure that samples and mobile phases are particle-free. The use of guard columns or an in-line filter with 0.5 μm porosity between the sample injector and the column is highly recommended. The 2 μm porosity frits on Ascentis Express 5 μm HILIC columns are less subject to pluggage than are the 0.5 μm frits typically used with other small-particle columns. Should the operating pressure of the column suddenly increase beyond normal levels, reversing the flow direction of the column may be attempted to remove debris on the inlet frit.
Helpful?
-