Skip to Content
MilliporeSigma
Get up to 22% off for Pi Day until 3/26.Save Now

57330-U

SPME Fiber Holder

greener alternative

for use with Manual Sampling, pk of 1

Synonym(s):

Solid Phase Microextraction Fiber Holder

Sign In to View Organizational & Contract Pricing.

Select a Size

1 EA

$759.00

$759.00


Check Cart for Availability

Request a Bulk Order

About This Item

NACRES:
NB.21
UNSPSC Code:
41115724

Skip To

Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist

packaging

pk of 1

greener alternative product characteristics

Waste Prevention
Safer Solvents and Auxiliaries
Learn more about the Principles of Green Chemistry.

sustainability

Greener Alternative Product

technique(s)

solid phase microextraction (SPME): suitable

compatibility

for use with Manual Sampling

greener alternative category

Quality Level

Looking for similar products? Visit Product Comparison Guide

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
57357-U57299-U548551-U
compatibility

for use with manual sampling

compatibility

for use with 15 mL vials

compatibility

Autosampler, for analyte group flavors (volatiles and semivolatiles, C3-20) (MW 40-275)

compatibility

(for gasses and low molecular weight compounds (MW 30 - 225)), for use with PAL 3, Series II Smart autosampler

greener alternative product characteristics

Waste Prevention
Safer Solvents and Auxiliaries
Learn more about the Principles of Green Chemistry.

greener alternative product characteristics

Waste Prevention
Safer Solvents and Auxiliaries
Learn more about the Principles of Green Chemistry.

greener alternative product characteristics

Waste Prevention
Safer Solvents and Auxiliaries
Learn more about the Principles of Green Chemistry.

greener alternative product characteristics

Waste Prevention
Safer Solvents and Auxiliaries
Learn more about the Principles of Green Chemistry.

sustainability

Greener Alternative Product

sustainability

Greener Alternative Product

sustainability

Greener Alternative Product

sustainability

Greener Alternative Product

technique(s)

solid phase microextraction (SPME): suitable

technique(s)

solid phase microextraction (SPME): suitable

technique(s)

solid phase microextraction (SPME): suitable

technique(s)

solid phase microextraction (SPME): suitable

greener alternative category

Aligned,

greener alternative category

Aligned,

greener alternative category

Aligned,

greener alternative category

, Aligned

Quality Level

100

Quality Level

100

Quality Level

100

Quality Level

-

General description

The holder protects the coated fiber, and controls exposure of the fiber during analyte adsorption and desorption. The holder is reusable indefinitely and accepts the replaceable fiber assembly. First time users must order both a holder and a fiber assembly.

Fiber Holder for Manual Sampling

An adjustable depth guide positions the fiber for sampling and for correct placement in the heated zone of the GC injection port. The fiber can be locked in the exposed position.

Fiber Holder for Automated Sampling or HPLC Analysis

Use this fiber holder with a Varian 8100/8200 AutoSampler or with our SPME/HPLC interface. An SPME upgrade kit is necessary for operation with the Varian AutoSampler - contact Varian Instrument Division for information concerning system requirements.

Fiber Holder for CTC CombiPAL/CombiPAL-xt and Gerstel MPS2
We are committed to bringing you greener alternative products, which adhere to one or more of The 12 Principles of Greener Chemistry. This is a Solid Phase Microextraction (SPME) technology product. SPME is one of the greener technologies for sample preparation as it is solvent free extraction technology and SPME fibres are re-usable and generates as little waste as possible, thus aligns with "Waste Prevention”, and ″Safer Solvents and Auxiliaries″. Click here for more information.

Application

The SPME Fiber Holder is designed for manual sampling, allowing precise control over the extraction process. It facilitates the integration of sampling, extraction, concentration, and sample introduction into a single solvent-free step. This reduces the need for complex, multi-step procedures and minimizes the use of organic solvents. The holder is compatible with various fiber coatings, making it suitable for a wide range of analytical applications.

Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documents section.

If you need assistance, please contact Customer Support

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Na Li et al.
Food chemistry, 332, 127426-127426 (2020-07-04)
A selected Pichia fermentans strain was simultaneously and sequentially inoculated in synthetic and real juice with S. cerevisiae strains of different antagonistic activities in a ratio 1:1 to observe the correlation between varietal odorants and glycosidase activities. Fermentations using pure
Edited by Sue Ann Scheppers Wercinski
Solid Phase Microextraction: A Practical Guide, 257-257 (1999)
Abdelhamid Neggad et al.
Chemistry & biodiversity, 16(10), e1900267-e1900267 (2019-08-17)
The volatile composition of seven honey samples collected from various regions of Algeria and feeding on different plants have been determined. The Headspace Solid-Phase MicroExtraction (HS-SPME) coupled with Gas Chromatography-Mass Spectrometry (GC/MS) was used to achieve the purpose. In this
Talon, R., Montel, M.
Applied SPME, 364-371 (1999)
Pawliszyn, Janusz
Solid Phase Microextraction: Theory and Practice, 264-264 (1997)

Articles

A direct immersion SPME method using a new overcoated SPME fiber was developed for the extraction of pesticides from pureed prune baby food.

Analysis of Tetrahydrocannabinol (THC) and Carboxytetrahydrocannabinol (THCCOOH) in Surface Waters by SPME and GC/MS

A throughput HS-SPME-GC-MS method to analyze volatile compounds in Perilla leaves at low extraction temperatures using four different SPME fibers.

The work describes the development of an HS-SPME-GC-MS method to determine 2-chloroethanol as a marker of fumigant ethylene oxide in different kinds of sesame seed samples.

Protocols

SPME enables rapid, sensitive GC/MS analysis of residual solvents in hemp extract, ensuring accuracy and efficiency.

High performance, reliability, and reproducibility of HS-SPME in combination with GC/MS for the determination of VOCs in water was proven in an interlaboratory trial. The new ISO 17943 using HS-SPME is an improvement on existing official methods for this determination in terms of sensitivity and selectivity.

This report demonstrates the potential of solid phase microextraction as a clinical research tool for the extraction of VOCs associated with lung cancer from human breath.

Se probaron el alto rendimiento, la fiabilidad y la reproducibilidad de la microextracción en fase sólida en espacio de cabeza (HS-SPME) en combinación con cromatografía de gases/espectrometría de masas (GC/MS) para la determinación de los compuestos orgánicos volátiles (COV) en agua en un ensayo interlaboratorio. La nueva ISO 17943 en la que se utiliza HS-SPME supone una mejora de los métodos oficiales existentes para esta determinación en cuanto a sensibilidad y selectividad.

Related Content

La microextracción en fase sólida (SPME) es una técnica de preparación de muestras sin disolvente en la que se utilizan fibras recubiertas para extraer analitos de interés de una muestra antes del análisis mediante GC o HPLC.

Solid phase microextraction (SPME) is a solvent-free sample preparation technique that uses coated fibers to extract analytes of interest from a sample before analysis by GC or HPLC.

Questions

1–6 of 6 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  3. What GC injection septa should be used when using the SPME Fiber Holder, Product 57330-U?

    1 answer
    1. We recommend the use of molded Thermogreen LB-2 septa with an injection hole.

      Helpful?

  4. Can I put the SPME Fiber Holder, Product 57330-U, in the oven for conditioning?

    1 answer
    1. No, the barrel is made of a black polymeric material and it will melt.

      Helpful?

  5. Can I use the SPME Fiber Holder, Product 57330-U, with any GC model?

    1 answer
    1. This SPME holder is designed to be used with manually with any GC having an appropriate, straight inlet liner.

      Helpful?

  6. What is the Department of Transportation shipping information for this product?

    1 answer
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      Helpful?

Reviews

No rating value

Active Filters

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service