Skip to Content
MilliporeSigma

Skip To

581325-U

Ascentis® C18 (5 µm) HPLC Columns

L × I.D. 25 cm × 4.6 mm, HPLC Column

Synonym(s):

Ascentis RP18 HPLC Column

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Size/SKUAvailabilityPrice
1 ea
Check Cart for Availability
$1,220.00

About This Item

UNSPSC Code:
41115700
eCl@ss:
32110501
NACRES:
SB.52
L × i.d.:
25 cm × 4.6 mm
Particle size:
5 μm
Matrix active group:
C18 (RP18), C18 (octadecyl) phase
Pore size:
100 Å
Matrix:
fully porous particle, silica gel high purity, spherical

$1,220.00


Check Cart for Availability

​
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


Product Name

Ascentis® C18 HPLC Column, 5 μm particle size, L × I.D. 25 cm × 4.6 mm

material

stainless steel column

Quality Segment

agency

suitable for USP L1 (Similar to Phenomenex Luna C18)

product line

Ascentis®

feature

endcapped

analyte functional class(es)

antibiotics, explosives, fat soluble vitamins, lipids, nutraceuticals and antioxidants, oils, pigments, sweeteners, water soluble vitamins

analyte chemical class(es)

PAHs, PCBs (aroclor identification), PFAS, aflatoxins, alcohols / fermentation, alcohols and aldehyde, aliphatic amines, alkaloids, amino acids, aromatic amines, cannabinoids as tms derivatives, carotenoids, catecholamines, coloring compounds, essential oils, esters, fatty acids, flavonoids, glycans, ketones, metabolized steroids, nitrosamines, nucleic acids, nucleosides, oligonucleotides, organic phosphates, peptides, pesticides, phenols, phospholipids, phthalate esters, preservatives, proteins, steroids (cholesteryl esters), sulfonamides

manufacturer/tradename

Ascentis®

packaging

1 ea of

extent of labeling

25% Carbon loading

parameter

≤70 °C temp. range, 400 bar pressure (5801 psi)

technique(s)

HPLC: suitable, LC/MS: suitable

L × I.D.

25 cm × 4.6 mm

surface area

450 m2/g

surface coverage

3.7 μmol/m2

impurities

<5 ppm metals

matrix

fully porous particle, silica gel high purity, spherical

matrix active group

C18 (RP18), C18 (octadecyl) phase

particle size

5 μm

pore size

100 Å

operating pH range

2-8

application(s)

food and beverages

separation technique

reversed phase

General description

The Ascentis family of columns is the fourth generation of HPLC column technology from Supelco scientists. Ascentis columns are bonded on high purity, 100 Angstrom silica including 3, 5, and 10 micron particle size. Columns are designed for small molecule applications and are scalable from micro columns (1.0 mm I.D.) to preparative dimensions (50 mm I.D.). The family includes C18, C8, Phenyl, Si and embedded polar group phase, RP-Amide.

Ascentis C18 is an extremely stable and reliable first choice HPLC column that gives symmetric peak shape and excellent retention even for difficult compounds.

Application


  • Identification of recombinant human insulin and biosynthetic insulin analogues by multiplexed targeted unlabeled mass spectrometry of proteotypic tryptic peptides.: This study utilized the Ascentis® C18 HPLC column for the separation of proteotypic tryptic peptides in the identification of insulin analogues, highlighting its application in targeted mass spectrometry for proteomic analysis (Qasem RJ et al., 2019).

  • Development and validation of a novel stability-indicating HPLC method for the simultaneous assay of betamethasone-17-valerate, fusidic acid, potassium sorbate, methylparaben and propylparaben in a topical cream preparation.: This research developed and validated an HPLC method using the Ascentis® C18 HPLC column for the simultaneous assay of multiple compounds, demonstrating its robustness in stability testing of pharmaceutical formulations (Byrne J et al., 2014).

  • HPLC-DAD and HPLC-ESI-MS/MS methods for metabolite profiling of propolis extracts.: The study employed the Ascentis® C18 HPLC column for metabolite profiling of propolis extracts using HPLC-DAD and HPLC-ESI-MS/MS, showcasing its effectiveness in complex natural product analysis (Pellati F et al., 2011).

  • Practical comparison of 2.7 microm fused-core silica particles and porous sub-2 microm particles for fast separations in pharmaceutical process development.: This article compared different HPLC column technologies, including the Ascentis® C18, highlighting its performance in fast separations critical for pharmaceutical process development (Abrahim A et al., 2010).

Features and Benefits

  • Excellent retention
  • Symmetric peak shape
  • High reproducibility
  • Complete LC-MS compatibility

Other Notes

Discover LiChropur reagents ideal for HPLC or LC-MS analysis

Legal Information

Ascentis is a registered trademark of Merck KGaA, Darmstadt, Germany

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
581324U581320U581326U
description

5 μm particle size, L × I.D. 25 cm × 4.6 mm

description

5 μm particle size, L × I.D. 15 cm × 4.6 mm

description

3 μm particle size, L × I.D. 5 cm × 4.6 mm

description

5 μm particle size, L × I.D. 10 cm × 2.1 mm

separation technique

reversed phase

separation technique

reversed phase

separation technique

reversed phase

separation technique

reversed phase

particle size

5 μm

particle size

5 μm

particle size

3 μm

particle size

5 μm

matrix active group

C18 (RP18), C18 (octadecyl) phase

matrix active group

C18 (octadecyl) phase, C18 (RP18)

matrix active group

C18 (octadecyl) phase, C18 (RP18)

matrix active group

C18 (RP18), C18 (octadecyl) phase

L × I.D.

25 cm × 4.6 mm

L × I.D.

15 cm × 4.6 mm

L × I.D.

5 cm × 4.6 mm

L × I.D.

10 cm × 2.1 mm

matrix

fully porous particle, silica gel high purity, spherical

matrix

silica gel high purity, spherical, fully porous particle

matrix

silica gel high purity, spherical, fully porous particle

matrix

fully porous particle, silica gel high purity, spherical

agency

suitable for USP L1 (Similar to Phenomenex Luna C18)

agency

suitable for USP L1 (Similar to Phenomenex Luna C18)

agency

suitable for USP L1 (Similar to Phenomenex Luna C18)

agency

suitable for USP L1 (Similar to Phenomenex Luna C18)


Still not finding the right product?

Explore all of our products under Ascentis® C18 HPLC Column


Storage Class

11 - Combustible Solids

WGK

nwg

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable



Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documents section.

If you need assistance, please contact Customer Support

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library



Questions

1–3 of 3 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  2. Is the column polar-embedded with amorphous organosilica polymer as the stationary phase? Can you share COA?

    1 answer
    1. The stationary phase of this column consists of fully porous Type B (high purity) spherical silica particles modified with an octadecyl (C18) bonding phase, which can be considered an amorphous organosilica polymer. However, the Ascentis® C18 stationary phase is not polar-embedded, as the bonding chemistry does not include a polar functionality such as the palmitamidopropyl modification seen in the related Ascentis® RP-Amide product line.

      Helpful?

  3. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters