MilliporeSigma
All Photos(1)

Documents

RAD170S

radiello Hydrogen Sulfide Starter Kit

Sign Into View Organizational & Contract Pricing

Select a Size

Synonym(s):
radiello Starter Kits
NACRES:
NB.24

Agency

NIOSH 6013 (*Note: This product is not officially specified in the method, it may be suitable for use for sampling compound(s) listed in the method*)
OSHA 1008 (*Note: This product is not officially specified in the method, it may be suitable for use for sampling compound(s) listed in the method*)

packaging

pkg of 1 kit (Kit includes: 2 RAD170 adsorbing cartridges and barcode labels, 1 RAD120 white diffusive body, 1 RAD121 triangular support plate, 1 instruction sheet)

manufacturer/tradename

Radiello

technique(s)

passive air sampling: suitable

matrix

microporous PE coated with zinc acetate

application(s)

air monitoring
environmental
industrial hygiene

compatibility

for sampling Hydrogen sulfide

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
RAD141SRAD145SRAD170
radiello™ Cartridge Adsorbents for sampling Hydrogen Sulfide (H2S), matrix microporous PE coated with zinc acetate, pk of 20

RAD170

radiello Cartridge Adsorbents

technique(s)

passive air sampling: suitable

technique(s)

passive air sampling: suitable

technique(s)

passive air sampling: suitable

technique(s)

passive air sampling: suitable

packaging

pkg of 1 kit (Kit includes: 2 RAD170 adsorbing cartridges and barcode labels, 1 RAD120 white diffusive body, 1 RAD121 triangular support plate, 1 instruction sheet)

packaging

pkg of 1 kit (2 RAD141 adsorbing cartridges and barcode labels, 1 RAD1202 yellow diffusive body, 1 RAD121 triangular support plate, 1 instruction sheet)

packaging

pkg of 1 kit (2 RAD145 adsorbing cartridges and barcode labels, 1 RAD1202 yellow diffusive body, 1 RAD121 triangular support plate, 1 instruction sheet)

packaging

pk of 20

manufacturer/tradename

Radiello

manufacturer/tradename

Radiello

manufacturer/tradename

Radiello

manufacturer/tradename

Radiello

matrix

microporous PE coated with zinc acetate

matrix

SS net packed with Carbopack X

matrix

SS net (3 x 8 μm, 4.8 mm diam.), Carbograph

matrix

microporous PE coated with zinc acetate

application(s)

air monitoring
environmental
industrial hygiene

application(s)

air monitoring
environmental
industrial hygiene

application(s)

air monitoring
environmental
industrial hygiene

application(s)

air monitoring
environmental
industrial hygiene

General description

Radiello Starter Kits are ideal for introducing you to the product and include everything you need to take one complete sample. No additional parts are required. Each kit includes the following items:

Each RAD130S Starter Kit Includes:
Two radiello cartridge adsorbents - Solvent Desorption Note: 1 x cartridge for sampling; and 1 x for blank)
1 x Triangular support plate (RAD121)
1 x vertical adapter for personal sampling (RAD122)
1 x white diffusive body (RAD120)
1 x barcode label (RAD190)
Detailed sampling/analysis instructions


Each RAD141S and 145S Starter Kit Includes:
Two radiello cartridge adsorbents - Thermal Desorption (Note: 1 x cartridge for sampling; and 1 x for blank)
1 x Triangular support plate (RAD121)
1 x vertical adapter for personal sampling (RAD122)
1 x yellow diffusive body (RAD1202)
1 x barcode label (RAD190)
Detailed sampling/analysis instructions

Legal Information

radiello is a trademark of Institi Clinici Scientifici Maugeri

Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

Customers Also Viewed

Slide 1 of 5

1 of 5

radiello™ Cartridge Adsorbents for sampling HF, NO2, and SO2, matrix microporous PE impregnated with wet TEA, pk of 20

RAD166

radiello Cartridge Adsorbents

radiello™ Diffusive Bodies white, configured for general use, pk of 20

RAD120

radiello Diffusive Bodies

radiello™ Outdoor Shelter pk of 10

RAD196

radiello Outdoor Shelter

radiello™ Vertical Adapter threaded for standard use, pk of 20

RAD122

radiello Vertical Adapter

J Dekeirsschieter et al.
Forensic science international, 189(1-3), 46-53 (2009-05-09)
Forensic entomology uses pig carcasses to surrogate human decomposition and to investigate the entomofaunal colonization. Insects communicate with their environment through the use of chemical mediators, which in the case of necrophagous insects, may consist in the cadaveric volatile organic
Armelle Vallat et al.
Phytochemistry, 66(13), 1540-1550 (2005-06-14)
Headspace volatiles from apple-bearing twigs were collected in the field with a Radiello sampler during three different diurnal periods over the complete fruit growing season. Analyses by thermal desorption-GC-MS identified a total of 62 compounds in changing quantities, including the
Benoît Oury et al.
Journal of occupational and environmental hygiene, 3(10), 547-557 (2006-08-16)
Diffusive sampling is particularly suited to determine time-weighted average volatile organic compound (VOC) concentration in occupational hygiene and environmental air monitoring. The purpose of this study was to measure the sampling rate variation of four different samplers in a special
Anne Pennequin-Cardinal et al.
Talanta, 65(5), 1233-1240 (2008-10-31)
Radiello((R)) diffusive samplers filled with a thermally desorbable adsorbent (graphitised charcoal Carbograph 4) have been tested for the monitoring of BTEX. The sampling rates have been estimated under various controlled atmospheres in order to evaluate the effects of two factors
Rocco Rella et al.
The Science of the total environment, 487, 255-259 (2014-05-03)
The proofing treatment of the floor slabs with a solvent based material and successive treatment with epoxy resin resulted in significant air contamination in a primary school. The contamination caused illnesses in many occupants of school. The GC/MS investigations of

Articles

How Does the Diffusive Sampler Work? Why is it so Special?

Learn the how the diffusive air sampler works to see if it’s the right fit for you.

Protocols

How to use the radiello® Diffusive Air Sampler

Learn how to assemble the supporting plate of your radiello air sampler in the lab before the sampling campaign to save time in the field.

Related Content

What is radiello® diffusive sampling?

Learn about radiello diffusive sampling and why it’s the best option for your air quality needs.

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service