Millex® Syringe Filters
Setting the standard in small-volume filtration (1-200 mL), the unsurpassed consistency of Millex® syringe filters in sample preparation has led to the development of many methods specifying their use. Our controlled manufacturing process ensures reliable filter performance. Featuring reduced sample loss due to minimal hold-up volumes, Millex® syringe filters are ideal for use in a variety of applications including:
- HPLC sample preparation
- Filtration of antibiotics and tissue culture additives
- Dissolution testing
- Hard-to-filter, nonsterile samples
- Medical applications
- Air and gas venting with hydrophobic PTFE membranes
Learn more about Millex® syringe filter formats and applications.
- How to choose Millex® filters by membrane type
- How to choose Millex® filters by sample volume
Durapore® PVDF Membrane
- Lowest binding
Millipore Express® PLUS Polyethersulfone (PES) Membrane
- Fast flow rates and low protein binding for cell culture media preparation
Hydrophilic PTFE Membrane
- Lowest HPLC-UV extractables with broadest chemical compatibility
Hydrophobic PTFE Membrane
- Excellent solvent resistance; vent applications
Nylon Membrane
- Broad chemical compatibility
MCE (mixed cellulose esters) Membrane
- Most referenced general purpose membrane
Glass Fiber Filter
- Clarification of solutions containing high particulate levels
|
---|
Sterile Millex® Syringe Filters
- Applications include sterilizing cell culture reagents such as cell culture media, antibiotics, supplements, sera, viruses for infection, and other biological solutions
- Fast flow and low binding for cell culture media preparation with Millipore Express® PLUS polyethersulfone (PES) membrane
- Durapore® PVDF membrane is the lowest binding membrane for protein-rich solutions
- Many are CE-marked and/or FDA registered for medical intended use
- Minimal leaching of impurities into filtered solutions
- 50 mm Millex® syringe filters have hydrophobic chemistry for gas filtration and in-line vacuum pump protection, and are autoclavable
Non-sterile Millex® Syringe Filters
- Applications include filtration-based sample preparation for dissolution testing, HPLC, UHPLC, LC-MS, ion chromatography (IC), and general particulate removal
- Hydrophilic PTFE Millex® filters are HPLC-certified for low extractables
- Best recovery of protein samples with hydrophilic Durapore® PVDF Millex® syringe filters
- Automation-compatible, non-sterile Millex® syringe filter units have a domed housing which enables smooth, reliable delivery in automated sample preparation workstations by eliminating shingling between filters on the transport rack.
- Nonsterile HPF Millex® filters include a graduated glass fiber prefilter to remove larger particles and either a 0.2 µm or 0.45 µm membrane filter for fine filtration. This combination of prefilter and membrane provides significantly greater throughput than standard filters without prefiltration media, especially when filtering particle laden solutions.
- 50 mm Millex® syringe filters have hydrophobic chemistry for gas filtration and in-line vacuum pump protection
Learn more about factors affecting analyte binding to syringe filters
Related Resources
- Article: Syringe Filters
Answers to common syringe filter selection questions, such as sterile vs non-sterile, how to use, membrane and housing types, and pore size.
- Poster: Millex Wall Chart
Sterile Millex® syringe filters you can trust. Research Applications: Sterile filtration of tissue culture media and additives / Buffers / DMSO / Biological solutions.
- Article: Dissolution Testing Filtration
Filtration is used in dissolution testing to end the dissolution process and prepare the sample for HPLC analysis. This page discusses the importance of filtration and utility of hydrophilic PTFE Millex® syringe filters in dissolution testing.
- Webinar: Filtration in Dissolution Testing: Improving Throughput and Reducing Variability
In vitro dissolution testing is used to characterize drug compounds throughout their development. In early drug development it is used to support the choice of a particular formulation. During drug production it is a critical component of the quality control process and is used to assess the changes in manufacturing processes or formulation. In order for dissolution results to be meaningful at each stage, the test and the process need to be reliable, consistent, predictive and accurate.
- Article: Filter Validation Studies for Pharmaceutical QC - Factors Affecting Analyte Binding
Syringe membrane filter selection and validation methods to assess analyte loss due to membrane filter adsorption in pharmaceutical quality control (QC) testing.
- Article: Universal Hydrophilic Syringe Filters: Millex® Hydrophilic PTFE Syringe Filters for Chromatography
Millex® hydrophilic PTFE syringe filters boast broad chemical compatibility and are HPLC-certified, guaranteeing low extractables. With their robust performance, these filters can be used for a variety of samples without the risk of membrane failure or sample contamination.
To continue reading please sign in or create an account.
Don't Have An Account?