Showing 1-30 of 68 results for "49349"
STED microscopy resolves nanoparticle assemblies.
Willig K.I.; et al.
New Journal of Physics, 8(6), 106-106 (2006)
2PE-STED Microscopy with a Single Ti. Sapphire Laser for Reduced Illumination.
Li, Q.; Wang, Y.; et al
PLoS ONE, 9(2), e88464-e88464 (2014)
Richard S Agnes et al.
Journal of the American Chemical Society, 132(17), 6075-6080 (2010-04-13)
A fluorescent sensor of protein kinase activity has been developed and used to characterize the compartmentalized location of cAMP-dependent protein kinase activity in mitochondria. The sensor functions via a phosphorylation-induced release of a quencher from a peptide-based substrate, producing a...
Size-Dependent Localization and Quantitative Evaluation of the Intracellular Migration of Silica Nanoparticles in Caco-2 Cells.
Schubbe, S.; et al.
Chemistry of Materials, 24(5), 914-923 (2012)
STED microscopy reveals that synaptotagmin remains clustered after synaptic vesicle exocytosis.
Willig K.I.; et al.
Nature, 440(7086), 935-939 (2006)
Anna I Sulatskaya et al.
The journal of physical chemistry. B, 115(39), 11519-11524 (2011-08-26)
The fluorescence of the benzothiazole dye thioflavin T (ThT) is a well-known test for amyloid fibril formation. It has now become evident that ThT can also be used for structural investigations of amyloid fibrils and even for the treatment of...
Sub-diffraction imaging of nitrogen-vacancy centers in diamond by stimulated emission depletion and structured illumination
Xusan, Y., et al.
Royal Society of Chemistry Advances, 4(22), 11305-11305 (2014)
Frequency domain fluorescence microspectrometry: Application to cellular uptake and drug distribution.
Praus, P., et al.
Spectroscopy: An International Journal, 24, 303-307 (2010)
Frequency dependent detection in a STED microscope using modulated excitation light.
Ronzitti, E.; Harke, B.; Diaspro, A.
Optics Express, 21(1), 210-210 (2013)
Sub-Diffraction Nano Manipulation Using STED AFM.
Chacko, Jenu V.; et al.
PLoS ONE, 8(6), e66608-e66608 (2013)
Long working distance fluorescence lifetime imaging with stimulated emission and electronic time delay.
Lin, P.Y.; et al
Optics Express, 20(10), 11445-11450 (2012)
Kirill Kolmakov et al.
Chemistry (Weinheim an der Bergstrasse, Germany), 16(1), 158-166 (2009-12-02)
Fluorescent markers emitting in the red are extremely valuable in biological microscopy since they minimize cellular autofluorescence and increase flexibility in multicolor experiments. Novel rhodamine dyes excitable with 630 nm laser light and emitting at around 660 nm have been...
Fast, super resolution imaging via Bessel-beam stimulated emission depletion microscopy.
Zhang, P.; Goodwin, P.M.; Werner, J.H.
Optics Express, 22(10), 12398-12409 (2014)
Maturation of active zone assembly by Drosophila Bruchpilot.
Fouquet, W.; et al.
The Journal of Cell Biology, 186(1), 129-145 (2009)
Spatial organization of proteins in metastasizing cells.
Ronnlund, D.; et al.
Cytometry, 83(9), 855-865 (2013)
Block Copolymer Nanostructures Mapped by Far-Field Optics.
Ullal, C.K.; et al
Nano Letters, 9(6), 2497-2500 (2009)
Johanna Bückers et al.
Optics express, 19(4), 3130-3143 (2011-03-04)
We describe a STED microscope optimized for colocalization experiments with up to three colors. Two fluorescence labels are separated by their fluorescence lifetime whereas a third channel is discriminated by the wavelength of fluorescence emission. Since it does not require...
Nermin Seda Kehr et al.
Nanoscale, 2(4), 601-605 (2010-07-21)
Microcontact printing (mCP) is used to immobilize dyes and peptides asymmetrically, by a "peptide coupling" reaction, on monolayers of zeolite L crystals in the contact area between the stamp and the surface of the monolayer. Chemically patterned surfaces of monolayers...
Limin Ma et al.
The Analyst, 137(21), 5046-5050 (2012-09-13)
4-Nitro-1,8-naphthalic anhydride (NNA) was used to distinguish cysteine from homocysteine and other potentially interfering thiols through a novel sequential substitution mechanism. The discrimination involves a blue-fluorescent thioether formation via nucleophilic aromatic substitution of the nitro group by thiol, followed by...
Matthias Reuss et al.
Optics express, 18(2), 1049-1058 (2010-02-23)
Stimulated emission depletion (STED) microscopy usually employs a scanning excitation beam that is superimposed by a donut-shaped STED beam for keeping the fluorophores at the periphery of the excitation spot dark. Here, we introduce a simple birefringent device that produces...
Dominik Wildanger et al.
Optics express, 16(13), 9614-9621 (2008-06-26)
We report on a straightforward yet powerful implementation of stimulated emission depletion (STED) fluorescence microscopy providing subdiffraction resolution in the far-field. Utilizing the same super-continuum pulsed laser source both for excitation and STED, this implementation of STED microscopy avoids elaborate...
Nanoscale organization of nicotinic aceylcholine receptors by stimulated emission depletion microscopy.
Kellner, R.R., et al.
Neuroscience, 144(1), 135-143 (2007)
Two-photon excitation STED microscopy
Moneron, G.; Hell, S. W.
Optics Express, 17(17), 14567-14573 (2009)
STED nanoscopy combined with optical tweezers reveals protein dynamics on densely covered DNA.
Heller, I.; et al.
Nature Methods, 10(9), 910-916 (2013)
Katrin I Willig et al.
Nature methods, 4(11), 915-918 (2007-10-24)
We report stimulated emission depletion (STED) fluorescence microscopy with continuous wave (CW) laser beams. Lateral fluorescence confinement from the scanning focal spot delivered a resolution of 29-60 nm in the focal plane, corresponding to a 5-8-fold improvement over the diffraction...
Experimental Proof of Concept of Nanoparticle-Assisted STED.
Sonnefraud, Y.; et al
Nano Letters, 14(8), 4449-4453 (2014)
A novel nanoscopic tool by combining AFM with STED microscopy.
Harke, B.; et al
Optical Nanoscopy, 1(1), 3-3 (2012)
STED imaging of green fluorescent nanodiamonds containing nitrogen-vacancy-nitrogen centers.
Laporte, G.; Psaltis, D.
Biomedical Optics Express, 7(1), 34-44 (2016)
Self-Calibrated Line-Scan STED-FCS to Quantify Lipid Dynamics in Model and Cell Membranes.
Benda, A.; Ma, Y.; Gaus, K.
Biophysical Journal, 108(3), 596-609 (2015)
Post-fusion structural changes and their roles in exocytosis and endocytosis of dense-core vesicles.
Chiang, HC.; et al
Nature Communications, 5, 3356-3356 (2014)

Social Media

LinkedIn icon
Twitter icon
Facebook Icon
Instagram Icon

MilliporeSigma

Research. Development. Production.

We are a leading supplier to the global Life Science industry with solutions and services for research, biotechnology development and production, and pharmaceutical drug therapy development and production.

© 2021 Merck KGaA, Darmstadt, Germany and/or its affiliates. All Rights Reserved.

Reproduction of any materials from the site is strictly forbidden without permission.