Skip to Content
MilliporeSigma
Search Within
Document Type

multiscreen hts vacuum manifold multiwell plates

Applied Filters:
Keyword:'multiscreen hts vacuum manifold multiwell plates'
Showing 1-30 of 53 results for "multiscreen hts vacuum manifold multiwell plates" within Technical Documents
MultiScreen HTS Vacuum Manifold
MultiScreenHTS vacuum manifold is ideal for multiwell filter plate applica- tions in both manual and automated laboratory environments. The manifold supports a wide variety of MultiScreen platforms, including
User Guide
receiver plate and place the assembly in the base of the vacuum manifold. The collar fits over the assembly. See the MultiScreen®HTS Vacuum Manifold User Guide for details. NOTE: Optimal vacuum levels
MultiScreen HTS 384 Hydrophilic PVDF Filter Plates
Compatible with existing MultiScreen™HTS vacuum manifold and its DirectStack™ technology    MultiScreen®HTS 384 Hydrophilic PVDF Filter Plates 384-well plates incorporate optimized hydrophilic
MultiScreen® and Millicell® Filter Plates for Assay Development
collection plate and reading in a Tecan Spectrafluor™ Plus plate reader. 39 Vacuum Filtration MultiScreen®HTS Vacuum Manifold Description Qty/Pk Cat. No. MultiScreen®HTS vacuum manifold
MultiScreenHTS-PH Phosphocellulose Filter Plates
PC0027EN00: Protein Kinase Assays on MultiScreen®HTS-PH 384-well Filter Plates, AN1017EN00: Kinase Assays Performed Entirely in the MultiScreenHTS-PH 384-well Filter Plate, or AN1018EN00: Use of MultiScreenHTS-PH
MultiScreen® HTS Vacuum Manifold User Guide
15MultiScreen®HTS Vacuum Manifold Determining Plate Type The MultiScreen®HTS Vacuum Manifold works well with MultiScreen® filter plates and a variety of collection plates. This table describes
MultiScreen HTS Glass Fiber Filter Plates
MultiScn HTS 384_PF1150EN00.qxd MultiScreen®HTS Glass Fiber Filter Plates 384- and 96-well plates incorporate optimized glass fiber for assays including receptor-ligand binding E Plate designs
User Guide-MVHVN4525|MVFCN1225|MSVMHTSHV|MVCPN0025
Use the MultiScreen® High Volume Filter Plate The MultiScreen® High Volume Filter Plate is designed for use with a MultiScreen®HTS Vacuum Manifold. Assembly Refer to the MultiScreen®HTS Vacuum Manifold
User Guide-MSVMHTS0D
MSVMHTS0D 1 MultiScreen®HTS Vacuum Manifold MSVMHTS00 1 MultiScreen® Deep Well Solvinert™ Plate, 0.45 µm, philic, non-sterile MDRLN0410 10 MultiScreen® Deep Well Solvinert™ Plate, 0.45 µm, phobic
Montage Plasmid MiniprepHTS Kit User Guide
clearing plate into the MultiScreen HTS PLASMID plate. Discard the MultiScreen HTS CLEARING plate. 8. Place the MultiScreen HTS PLASMID plate on top of the manifold collar. Apply vacuum at
MultiScreen HTS 384-Well Plates
liquid into filter plates ■ Vacuum manifold (Millipore cat. no. MSVM HTS 00) or centrifuge with a swinging bucket rotor and multiwell plate carrier ■ Solid bottom 384-well assay plates (if collecting
Novel radioligand binding assays with GPCR membranes prefrozen on MultiScreen HTS glass fiber filter plates (Ready-To-Assay plates)
Millipores’s MultiScreen®HTS Filter Plate technology 1. The deep wells of the MultiScreenHTS filter plates permit binding reactions to be performed in the filter plate 2. Vacuum manifold is used for
MultiScreen HTS PLASMID 96-Well Plates User Guide
from the plate. Materials Required In order to use the MultiScreenHTS PLASMID plates you will need: ■ MultiScreenHTS vacuum manifold (Cat. No. MSVM HTS 00) ■ MultiScreenHTS CLEARING plates (Cat. No.
Poster: Automation of Receptor-Ligand Binding Assays using the MultiScreen HTS Filter Plate
a filter plate RadioLigand Comp. Ligand Receptor V-Bottom w/ Stocks: Tip Disposal Chute Vacuum Manifold In-Plate Receptor/Ligand Binding in MultiScreen® Filter Binding Plates 3.)
Aqueous Solubility Testing with the MultiScreen HTS - PCF Filter Plate
with the MultiScreen®HTS – PCF Filter Plate Application note table 1. comparison of the shake-flask & Multiscreen solubility tests at pH 7.4 solubility drug shake-Flask Multiscreen Tamoxifen
Adrenergic receptor family membrane preparation array with Millipore's MultiScreen HTS + Hi Flow 96-well glass fiber filter plates
filter plates and vacuum manifold are designed to be used with standard automation equipment Add 0.1% PEI to MultiScreen-FC plate Filter PEI through plate with vacuum manifold Wash plate with
MultiScreenHTS Filter Plates: New plate design for full automation compatibility
Solubility filter plate. The 48 adjacent wells received an equivalent volume of PBS. The filter plate was subsequently placed on a MultiScreen vacuum manifold containing a 96 well collection plate and the samples
Kinase Assays Performed Entirely in the MultiScreen® HTS–PH 384-well Phosphocellulose Filter Plate
Phosphoric acid. Out-of-plate reactions were transferred from the reaction plate to the prewet filter plate. All filter plates were washed 5 times under vacuum on a vacuum manifold (Millipore cat# MSVMHTS00
Automating Radioisotopic Protein Kinase Assays in Phosphocellulose Filter Plates
#14501016). An entire in-plate assay involving transfer from four 96-well compound plates into a MZPH filter plate set on a MultiScreenHTS Vacuum Manifold (Millipore #MSVM HTS 00), excluding incubation
MultiScreen®Filter Plates Poster
with the MultiScreen®HTS Vacuum Manifold Plate-on-plate stacking eliminates gaps between flow directors and receiver wells in applications that require filtrate collection. 1. Manifold Collar
MultiScreen Harvest Plates
the addition of MultiScreen Harvest Plates, Millipore now pro- vides a complete line of 96-well filter plates for high throughput screening (HTS) applications. Fill all your HTS filter plate needs in one
User Guide - MAHVN4510/MAHVN4550/MSHVN4510/MSHVN4550
MultiScreen®HTS-HV plates are automation-compatible for use with a variety of robotics systems and can be barcoded on all four sides . These plates should be used with a MultiScreen®HTS Vacuum Manifold
MultiScreen Ultracel®-10 filter plates: Purification of Serum Peptides for Biomarkers Research
reflector mode. • Millipore, Multiscreen Vacuum Manifold #MAVM0960R Reagents • Human serum (Sigma) from clotted male whole blood donor, lot 22K 0965 • Other human serum obtained in-house from healthy
User Guide-MAHVN4510|MAHVN4550|MSHVN4510|MSHVN4550
. MultiScreen®HTS-HV plates are automation-compatible for use with a variety of robotics systems and can be barcoded on all four sides. These plates should be used with a MultiScreen®HTS Vacuum Manifold
Use of MultiScreenHTS 384 Filter Plates on the Wallac MicroBeta Trilux Plate Reader to Achieve Optimal Radiometric Assay Results
.doc Applications Note Title: Use of MultiScreen®HTS 384 Filter Plates on the Wallac MicroBeta®Trilux Plate Reader to Achieve Optimal Radiometric Assay Results
Brochure- Sterile Filteration Systems
-sterile-filters 15 Related Products: Multiwell Plates MultiScreen®HTS Filter Plates Automation-compatible MultiScreen® filter plates that contain a microporous membrane are ideal for clarifying
Sterile Filtration You Trust
-sterile-filters 15 Related Products: Multiwell Plates MultiScreen®HTS Filter Plates Automation-compatible MultiScreen® filter plates that contain a microporous membrane are ideal for clarifying
Multi-SPE Extraction Plates
MSPE NUR 01 Accessories MultiScreen™HTS Vacuum Manifold 1 MSVM HTS 00 Deep Well Collar 1 MSVM HTS 0D Deep Well Receiver Plate 50 MDCP N2M 50 Chemical Duty Pump 1 115 volts, 60 Hz WP61 115 60
Brochure-SLTEST000
-sterile-filters 15 Related Products: Multiwell Plates MultiScreen®HTS Filter Plates Automation-compatible MultiScreen® filter plates that contain a microporous membrane are ideal for clarifying
MultiScreen Caco-2 --Drug Transport Assembly in a 96-well system:
pass- ages 33-35 were used to seed one MultiScreen Caco-2 plate (96-well filter plate from cat. MACAC02S5 or MACAC02S2) and four 24-well plates for 21-day cell growth in four independent
Page 1 of 2