Search Within
Document Type
polypropylene adapter set
Applied Filters:
Keyword:'polypropylene adapter set'
Showing 1-30 of 140 results for "polypropylene adapter set" within Technical Documents
Millistak+®Pod disposable depth filter hardware
feed and filtrate manifold MP0DDSPMAN3
Disposable adapter kit** 3 through adapters, 3 blind adapters 1 MP0DADAPT
Disposable adapter kit** 6 through adapters, required if using MP0DDIVERTR 1 MP0DADPTF
1.5
User Guide - XPEL3MAP
be used between cassettes.
The Manifold Adapter Plate will conform to the holder
and therefore should not be reinstalled once the
elastomer has set.
Refer to the Pellicon® 3 User Guide, AN1065EN00
Parts List Titristar P2000
AC270414-1
New Polypropylene Cap for Bottle AD274170-1
Paper for Impact Printer (roll, 5/pk) AS531178-1
Plunger Rod A3222951-1
Power Cord A7803181-1
Push Screw Set AE251236-1
Rubber
AQUASTAR®AQV21 Volumetric Titrator - Installation Information
steel
Titration stand Crastin® PBT
Lid (titration beaker) Polypropylene
Threaded ring Polypropylene
Three hole adapter Polypropylene
Dispensing tube / extraction tube FEP
Air tubes Silicone
Aldrich Kugelrohr and Chemical Dryer Apparatus
.
Step 4. Set timer and distillation
temperature with the front panel
keypad.
Step 5. Collect distillate in the
horizontal ball-tube outside the oven.
An ice-filled polypropylene cooling
tray
Quick Start Guide-MilliSentials™ Lab Labeling System
the Ribbon
1. Locate one of the plastic core adapters and push
through the ribbon core, in the orientation shown.
2. Place the plastic core adapter in the lower supply
spindle as shown with notches
Adapting the Polypropylene Hand Pump to the 20 Liter drum lid
Adapting the Polypropylene Hand Pump
to the 20 Liter drum lid
To dispense liquids from the 20 Liter HDPE Drum w/swing handle, The Polypropylene Solvent
Hand Pump (695060/1) can be adapted to
MAS-100 Atmos® Brochure
connection)
1.17354.0001
MAS-100 Atmos® Exhaust Tube Set
consists of 5 m tubing (Ø 40 mm) with tri-clamp (Ø 50.5 mm) and adapter 1.17349.0001
Adapter Gas Exhaust Tube for MAS-100 Atmos® (for use of alternative
Mobius® 3L Bioreactor User Guide
controller settings for the heating
blanket as excessive temperature may cause damage to the vessel.
Heating Blanket
2. Mount the motor onto the motor adapter (see Motor Adapter User Guide)
Stericap PLUS Universal Bottle-Top Filter Device
styrene
Outlet frit: Polypropylene
Gasket: Closed cell polyethylene foam
Tube set: Silicone, 1 m (3.2 ft)
Tube weight: PVDF
Vacuum port matrix: Cellulose acetate
Vacuum adapter: High density polyethylene
Vmax Constant Pressure
Polygard® CN Prefilter Polypropylene 0.3 SH1B947J1
Polygard® CN Prefilter Polypropylene 0.6 SH1B948J1
Polygard® CN Prefilter Polypropylene 1.2 SH1B949J1
Polygard® CN Prefilter Polypropylene 30 SH1B950J1
Polygard
Labscale™ Tangential Flow Filtration System
Diaphragm Pump Maintenance
Pump Panel Disassembly
1. Disconnect the AC adapter from its power source
2. Disconnect the AC adapter from the enclosure
3. Remove the Pump Panel from the enclosure
Millistak+® HC Pro
Disposable Adapters
Connect Millistak+® Process-Scale Pods to process piping, creating a disposable flow path.
MP0DADAPT – disposable adapter kit with 3 through adapters and 3 blind adapters
MP0DADPTF
Clarisolve® Depth Filters User Guide
d
Housing Glass filled polypropylene X X X
Adapters Glass Filled Polypropylene X
Gaskets
and Plugs Thermo Plastic Elastomer (TPE) X X
Filter
Media
20MS
Polypropylene and cellulose
fiber combined
User Guide - SCGPCAPRE
styrene
Outlet frit Polypropylene (PP)
Collar Impact resistant styrene
Gasket Closed cell polyethylene foam
Membrane Polyethersulfone (PES)
Tube set Silicone
Vacuum adapter High density polyethylene
Data Sheet
7
8
9
VersaCap® technology
with versatile adapters and
replaceable gasket
Available in Amber HDPE, or Dark
Amber Polypropylene
EZgrip™ body features
advanced ergonomic design
EZfil
Data Sheet
7
8
9
VersaCap® technology
with versatile adapters and
replaceable gasket
Available in Amber HDPE, or Dark
Amber Polypropylene
EZgrip™ body features
advanced ergonomic design
EZfil
Data Sheet - Millistak+® Pod depth filter system
Disposable Adapters
Connect Millistak+® Process-Scale Pods to process piping, creating a disposable flow path.
MP0DADAPT – disposable adapter kit with 3 through adapters and 3 blind adapters
MP0DADPTF
Technical Bulletin - (Z568023, Z568031, Z568058, Z568066, Z568074, Z568082)
is a custom adapter available
for connecting multiple Pure Solv™ Micro systems to a single
vacuum source. Please contact Sigma-Aldrich Labware for
information about these adapters, [email protected]
Specification Sheet: Mobius®Power MIX 2000 Single-Use Mixer
encased in polypropylene
Powder port Polyethylene
TC gasket Silicone
TC clamp Nylon
TC end cap Polypropylene
Cup HDPE
Probe port HDPE
O-ring Silicone
Plug Polypropylene
Needle-
AQUASTAR®AQC22 Coulometric Titrator - Installation Information
electrode
M Double platinum pin electrode
n Extraction adapter and park sleeve 1)
1) Component of the optionally available reagent changing set.
2) Not available with standard equipment.
Coulometric
Spare parts QuikScale® Chromatography columns
CELL—200 COLUMN BLACK POLYPROPYLENE 1
2 3 ADJUSTER HANDLE BLACK—M10 FEMALE x 65 mm LONG SEE SPEC 3 3
3 1 ADJUSTER SEAL SETTING RING GL200 COLUMN SST 316L 1
4 1 ADJUSTER STEM & ADAPTER ASSY—GL200 COLUMN 1
User Guide - Pod Depth Filters
Depth Filters
Housing Glass-filled polypropylene
Adapters Glass-filled polypropylene
Gaskets and Plugs Thermoplastic elastomer (TPE)
Filter Media
20MS, 40MS Polypropylene and cellulose fibers combined with
User Guide - 59683-U, 59680-U
and desorption solvents.
4. Load the Supel™ BioSPME C18 96-Pin Device into
the adapter, the adapter should be positioned in place
of 96-well plate.
5. Start automated program from the
Brochure - 109227
Change Tripod Adapter For quick adaption of MAS-100
® air sampler to tripod without
screwing 1.09223.0001 ✔ ✔ ➖
Tripod adapter for MAS-100 Eco® air sampler 1.09127.0001 ➖ ➖ ✔
Tube adapter For sampling
Multi-SPE Extraction Plates
provides consistent recoveries across the plate. The Multi-SPE plate also contains a graded-density
polypropylene prefilter secured above the Empore extraction disk. The prefilter is specifically designed to
Life Cycle Environmental Assessment Progard®Cartridge
center
- Label
- PVC caps
- Extruded polypropylene housing
- Polyethylene separators
- EPDM O-ring
- Coconut shell-derived activated carbon
- Polypropylene fi lter
- Polyphosphate crystals
- PE
AL-266 Self-Assembly Tech Spotlight
in a fume hood.
Containers - Appropriate containers include glass or
polypropylene (e.g., scintillation vials, polypropylene
test tubes and centrifuge tubes). If glass containers are
used, they must
Samplicity® G2 Filtration System with Millex Samplicity® and Millex Filters® User Guide
well capacity 5 mL
Materials of Construction
Base Polypropylene, silicone, stainless steel
Waste tray Recycled polyester (PET)
Vial tray Polypropylene, thermoplastic elastomer (TPE)
Lid/doors/seals Engineering
Data Sheet
unwrapped)
• One (1) plastic core adapter
• 1 inch diameter cardboard core adapter
• MilliSentials™ Lab Printer
Note: there are two (2) plastic core adapters included
with your system. They are
Page 1 of 5