Comparative evaluation of seven different sample treatment approaches for large-scale multiclass sport drug testing in urine by liquid chromatography-mass spectrometry.

Journal of chromatography. A (2014-08-21)
Juan C Domínguez-Romero, Juan F García-Reyes, Antonio Molina-Díaz
ABSTRACT

Sample preparation is a critical step in large-scale multiclass analysis such as sport drug testing. Due to the wide heterogeneity of the analytes and the complexity of the matrix, the selection of a correct sample preparation method is essential, looking for a compromise between good recoveries for most of the analytes and cleanliness of the extract. In the present work, seven sample preparation procedures based on solid-phase extraction (SPE) (with 5 different cartridges), liquid-liquid extraction (LLE) and sorbent-supported liquid extraction (SLE) were evaluated for multiclass sport drug testing in urine. The selected SPE sorbents were polymeric cartridges Agilent PLEXA™ and Oasis HLB™, mixed mode cation and anion exchange cartridges Oasis MAX™ and MCX™, and C18 cartridges. LLE was performed using tert-butyl methyl ether and SLE was carried out using Agilent Chem Elut™ cartridges. To evaluate the proposed extraction procedures, a list of 189 compounds were selected as representative from different groups of doping agents, including 34 steroids, 14 glucocorticosteroids, 24 diuretics and masking agents, 11 stimulants, 9 beta-agonist, 16 beta-blockers, 6 Selective Estrogen Receptors Modulators (SERMs), 24 narcotics and 22 other drugs of abuse/sport drugs. Blank urine samples were spiked at two levels of concentration, 2.5 and 25μgL(-1) and extracted with the different extraction protocols (n=6). The analysis of the extracts was carried out by liquid chromatography electrospray time-of-flight mass spectrometry. The use of solid-phase extraction with polymer cartridges provided high recoveries for most of the analytes tested and was found the more suitable method for this type of application given the additional advantages such as low sample and solvent consumption along with increased automation and throughput.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Formic acid solution, BioUltra, 1.0 M in H2O
USP
Methyl alcohol, United States Pharmacopeia (USP) Reference Standard
USP
Residual Solvent Class 2 - Acetonitrile, United States Pharmacopeia (USP) Reference Standard
USP
Glacial acetic acid, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Ammonium hydroxide solution, puriss., 30-33% NH3 in H2O
Sigma-Aldrich
Ammonium hydroxide solution, puriss., meets analytical specification of Ph. Eur., 25-30% NH3 basis
Sigma-Aldrich
Acetonitrile, ReagentPlus®, 99%
Sigma-Aldrich
Ammonium hydroxide solution, puriss. p.a. plus, ≥25% NH3 in H2O
Sigma-Aldrich
Formic acid, puriss., meets analytical specifications of DAC, FCC, 98.0-100%
Sigma-Aldrich
Ammonium hydroxide solution, puriss. p.a., reag. ISO, reag. Ph. Eur., ~25% NH3 basis
Sigma-Aldrich
Formic acid, puriss. p.a., ACS reagent, reag. Ph. Eur., ≥98%
Sigma-Aldrich
Ammonium hydroxide solution, ACS reagent, 28.0-30.0% NH3 basis
Sigma-Aldrich
Formic acid, reagent grade, ≥95%
Sigma-Aldrich
Acetonitrile, biotech. grade, ≥99.93%
Sigma-Aldrich
Acetonitrile, suitable for DNA synthesis, ≥99.9% (GC)
Sigma-Aldrich
Ammonium hydroxide solution, 28% NH3 in H2O, ≥99.99% trace metals basis
Sigma-Aldrich
Acetonitrile, puriss. p.a., ACS reagent, reag. Ph. Eur., ≥99.5% (GC)
Sigma-Aldrich
Acetonitrile, ACS reagent, ≥99.5%
Sigma-Aldrich
Formic acid, ACS reagent, ≥88%
Sigma-Aldrich
Acetonitrile
Sigma-Aldrich
Formic acid, ACS reagent, ≥96%
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acetonitrile, suitable for HPLC-GC, ≥99.8% (GC)
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acetonitrile, HPLC Plus, ≥99.9%
Supelco
Methanol solution, NMR reference standard, 4% in methanol-d4 (99.8 atom % D), NMR tube size 5 mm × 8 in.
Sigma-Aldrich
Methanol solution, NMR reference standard, 4% in methanol-d4 (99.8 atom % D), NMR tube size 3 mm × 8 in.
Supelco
Methanol solution, contains 0.10 % (v/v) formic acid, UHPLC, suitable for mass spectrometry (MS), ≥99.5%
Sigma-Aldrich
Acetonitrile, electronic grade, 99.999% trace metals basis
Supelco
Acetonitrile, Pharmaceutical Secondary Standard; Certified Reference Material