HiTrap® IMAC HP and HiTrap® IMAC FF are 1 ml and 5 ml columns prepacked with IMAC Sepharose® High Performance or IMAC Sepharose® 6 Fast Flow, respectively. Sample application, washing, and elution can be performed using a syringe with a supplied adapter, a peristaltic pump, or a liquid chromatography system such as ÄKTA.
HiTrap® IMAC HP and HiTrap® IMAC FF columns are made of polypropylene, which is biocompatible and noninteractive with biomolecules. The top and bottom frits are manufactured from porous polyethylene. Columns are delivered with a stopper on the inlet and a snap-off end on the outlet. Each package includes all necessary components for connecting the columns to different types of equipment. For quick scale-up of purifications, two or three HiTrap™ columns (1 ml or 5 ml) can be connected in series (back pressure will be higher). Note that HiTrap™ IMAC columns cannot be opened or refilled.
Figure 3.49.HiTrap™ IMAC HP 1 ml columns charged with Cu2+, Zn2+, Co2+ and Ni2+, respectively.
Sample and buffer preparation
Refer to Purification using IMAC Sepharose® High Performance or Purification using IMAC Sepharose® 6 Fast Flow for a general procedure for sample and buffer preparation, for HiTrap™ IMAC HP and HiTrap™ IMAC FF, respectively.
Charging the column with metal ion
Solutions of Zn2+ ions should have a pH of approximately 5.5 or lower to avoid solubility problems that arise at pH 6 or higher. Fe3+ ions should be immobilized at low pH (approximately pH 3.0) to avoid formation of insoluble ferric compounds.
Wash only with water, not buffer, prior to applying the metal ion solution, otherwise unwanted precipitation may occur.
The column does not need to be stripped and recharged between each purification if the same protein is going to be purified. Reuse of any purification column depends on the nature of the sample and should only be performed with identical tagged proteins to prevent cross-contamination. For more information on this topic and on cleaning and storage, refer to Appendix 1 (Characteristics of Ni Sepharose, Ni Sepharose® excel, TALON® Superflow, and uncharged IMAC Sepharose® products).
IMAC Sepharose® is compatible with reducing agents. However, we recommend removal of any weakly bound metal ions before applying buffer/sample that includes reducing agents. This can be accomplished by performing a blank run without reducing agents (see below). Do not leave or store HiTrap™ IMAC columns with buffers that include reducing agents.
For critical applications, leakage of metal ions during purification can be diminished by performing a blank run (as described on the next page) before loading sample.
Blank run:
Use binding buffer and elution buffer without reducing agents.
Purification
1 One ml/min corresponds to approximately 30 drops/min when using a syringe with a HiTrap™ 1 ml column, and 5 ml/min corresponds to approximately 120 drops/min when using a HiTrap™ 5 ml column.
The column does not need to be stripped and recharged between each purification if the same protein is going to be purified. Reuse of any purification column depends on the nature of the sample and should only be performed with identical tagged proteins to prevent cross-contamination. For more information on this topic and on cleaning and storage, refer to Appendix 1 (Characteristics of Ni Sepharose, Ni Sepharose® excel, TALON® Superflow, and uncharged IMAC Sepharose® products).
Purification screening using different metal ions
YNR064c (Mr 33 700) is a (histidine)6-tagged protein expressed in Pichia pastoris. It was purified using HiTrap IMAC HP 1 ml columns charged separately with Cu2+, Zn2+, Co2+, or Ni2+; conditions were otherwise the same for the four purifications. See Figures 3.50A–E for the resulting chromatograms and SDS-PAGE analysis of pooled fractions.
The results show that for this (histidine)6-tagged target protein, the highest purity was achieved with Ni2+ or Cu2+, although Cu2+, at the conditions used, apparently gave a small loss of target protein (Figure 3.50E, lane 4).
Figure 3.50.Purification of (histidine)6-tagged YNR064c expressed in Pichia pastoris on four different HiTrap IMAC HP 1 ml columns charged separately with metal ions (A) Cu2+, (B) Zn2+, (C) Co2+, or (D) Ni2+. Pools selected after SDS-PAGE of individual 1 ml fractions (not shown) are indicated. (E) SDS-PAGE analysis: reducing conditions on ExcelGel SDS Gradient 8–18; Coomassie staining.
To continue reading please sign in or create an account.
Don't Have An Account?