Saltar al contenido
MilliporeSigma

217506

Supelco

AmberChrom 50WX8 Ion Exchange Resin

hydrogen form, 100-200 mesh

Slide 1 of 1
Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización

Seleccione un Tamaño

100 G
$137.00
500 G
$468.00
2.5 KG
$1,740.00

$137.00


En stockDetalles


Solicite una orden a granel

Seleccione un Tamaño

Cambiar Vistas
100 G
$137.00
500 G
$468.00
2.5 KG
$1,740.00

About This Item

Fórmula lineal:
(C10H12 · C10H10 · C8H8)x
CAS Number:
Número MDL:
Código UNSPSC:
23151817
NACRES:
SB.52

Saltar a

Servicio técnico
¿Necesita ayuda? Nuestro equipo de científicos experimentados está aquí para ayudarle.
Permítanos ayudarle

$137.00


En stockDetalles


Solicite una orden a granel
Servicio técnico
¿Necesita ayuda? Nuestro equipo de científicos experimentados está aquí para ayudarle.
Permítanos ayudarle

Product Name

Dowex 50WX8 hydrogen form, hydrogen form, 100-200 mesh

descripción

cross-linkage 8%

Nivel de calidad

Formulario

beads

humedad

50-58%

técnicas

LPLC: suitable

Matriz

styrene-divinylbenzene (gel)

grupo activo de la matriz

sulfonic acid functional group

tamaño de partícula

100-200 mesh

capacidad

1.7 meq/mL by wetted bed volume

técnica de separación

cation exchange

cadena SMILES

C(C)c3c(cccc3)C=C.c2(c(cccc2)C=C)C=C.c1(ccccc1)C=C

InChI

1S/C10H12.C10H10.C8H8/c2*1-3-9-7-5-6-8-10(9)4-2;1-2-8-6-4-3-5-7-8/h3,5-8H,1,4H2,2H3;3-8H,1-2H2;2-7H,1H2

Clave InChI

NWUYHJFMYQTDRP-UHFFFAOYSA-N

¿Está buscando productos similares? Visita Guía de comparación de productos

Comparar elementos similares

Ver comparación completa

Mostrar Diferencias

1 of 4

Este artículo
217492217514422096
matrix

styrene-divinylbenzene (gel)

matrix

styrene-divinylbenzene (gel)

matrix

styrene-divinylbenzene (gel)

matrix

styrene-divinylbenzene (gel)

separation technique

cation exchange

separation technique

cation exchange

separation technique

cation exchange

separation technique

cation exchange

matrix active group

sulfonic acid functional group

matrix active group

sulfonic acid functional group

matrix active group

sulfonic acid functional group

matrix active group

sulfonic acid functional group

particle size

100-200 mesh

particle size

50-100 mesh

particle size

200-400 mesh

particle size

100-200 mesh

form

beads

form

beads

form

beads

form

beads

capacity

1.7 meq/mL by wetted bed volume

capacity

1.7 meq/mL by wetted bed volume

capacity

1.7 meq/mL by wetted bed volume

capacity

1.1 meq/mL by wetted bed volume

Descripción general

Amberlite­ HPR4800 Cl hydrogen form is used as stripper resin and can be regenerated by 0.25N sulphuric acid when exhausted.[1] Amberlite HPR4800 Cl hydrogen form is used as catalyst.[2] It is used in deionizing supernatant fraction samples for paper chromatography.[3]

Aplicación

Cumple los requisitos de la Normativa 21 CFR 173.25 de la FDA sobre aditivos para alimentación.
Amberlite HPR4800 Cl hydrogen form may be used in separation medium for TLC, paper chromatography and LPLC.

Otras notas

This resin has not been specially processed nor cleaned. We suggest that it be subjected to a suitable preliminary elution and wash.

Información legal

Amberchrom is a trademark of DuPont de Nemours, Inc.
Amberlite is a trademark of DuPont de Nemours, Inc.

Pictogramas

Exclamation mark

Palabra de señalización

Warning

Frases de peligro

Clasificaciones de peligro

Eye Irrit. 2

Código de clase de almacenamiento

13 - Non Combustible Solids

Clase de riesgo para el agua (WGK)

WGK 3

Punto de inflamabilidad (°F)

Not applicable

Punto de inflamabilidad (°C)

Not applicable

Equipo de protección personal

dust mask type N95 (US), Eyeshields, Gloves


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Questions

1–9 of 9 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  3. How can a Dowex 1x4 resin in the chloride form be converted to the acidic form?

    1 answer
    1. This product is a strongly acidic cation exchange resin in the H+ form. There is no way to convert between this and being in the chloride form, which would constitute an anion exchange resin. A resin cannot be converted from an anion exchange resin to a cation exchange resin, or vice versa. A resin in the H+ form can, however, be converted to the sodium form by flushing with two volumes of 1 N NaOH, whereby the sodium ions take the place of the hydrogen.

      Helpful?

  4. What is the meaning of 1.7 meq/mL by wetted bed volume for this resin? Do we have to consider the molecular mass of resin or the reaction mixture that we are going to purify?

    1 answer
    1. A milliequivalent is one-thousandth of an equivalent. The unit mEq is related to the number (mmol) and electrical charge of ions in solution. 1.7 mEq/mL means 1.7 millimoles of charge per milliliter of resin bed.

      Yes, you will need to consider the milliequivalents of charge on the resin and the millimoles of the material that you are trying to purify; make sure that the first is greater.

      Helpful?

  5. How can I convert a cation exchange resin from the hydrogen form to the sodium form?

    1 answer
    1. To convert a cation exhcange resin from the hydrogen form to the sodium form, use two to four bed volumes of 0.5-2.0% NaCl or NaOH.

      Helpful?

  6. What is the particle size of Product 217506, Dowex® 50WX8 - hydrogen form, 100-200 mesh resin?

    1 answer
    1. This is Dowex 50Wx8 100-200 mesh, with beads measuring 75-150 microns.  This particle size is consistent in water, but the resin will shrink when exchanged to other cationic forms, and it will swell when exposed to organic solvents. You may test the swelling characteristics of a resin to be used in your application by doing the initial solvent exchanges in a graduated cylinder.

      Helpful?

  7. How do I prepare Product 217506, Dowex® 50WX8 - hydrogen form, 100-200 mesh resin, for use?

    1 answer
    1. Cation exchange resins can be prepared by initially swirling with deionized water in a flask (no stir bars, please), allowing them to settle for 15-20 minutes, and decanting the fines.  To fully activate the resin, repeat the procedure 2-3 times with 2N hydrochloric or sulfuric acid, and rinse with copious amounts of water until >pH 5; this procedure may be completed with use of a Büchner funnel.

      Helpful?

  8. What is the Department of Transportation shipping information for this product?

    1 answer
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      Helpful?

  9. Is Product 217506, Dowex® 50WX8 - hydrogen form, 100-200 mesh resin, the same as AG50W-X8?

    1 answer
    1. The AG® designation indicates that a resin has been specially cleaned and certified for analytical use.  In most cases, resin that you prepare yourself will be suitable for your application.   (® Bio-Rad Laboratories, Hercules,CA)

      Helpful?

Reviews

No rating value

Active Filters

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico