DUO94004

Duolink® flowPLA Detection Kit - FarRed

Duolink® PLA kit for Flow Cytometry with FarRed Detection

Iniciar sesión para ver los precios por organización y contrato.

Seleccione un Tamaño

Cambiar Vistas
Tamaño de envaseSKUDisponibilidadPrecio
40 tests
Comprobar disponibilidad del carrito
$947.00

Acerca de este artículo

NACRES:
NA.32
UNSPSC Code:
41105331
Fluorescence:
λex 644 nm; λem 669 nm
Technique(s):
flow cytometry: suitable, immunofluorescence: suitable, proximity ligation assay: suitable

$947.00


Comprobar disponibilidad del carrito

Solicite una orden a granel
Servicio técnico
¿Necesita ayuda? Nuestro equipo de científicos experimentados está aquí para ayudarle.
Permítanos ayudarle


product line

Duolink®

technique(s)

flow cytometry: suitable, immunofluorescence: suitable, proximity ligation assay: suitable

fluorescence

λex 644 nm; λem 669 nm

suitability

suitable for fluorescence

shipped in

dry ice

storage temp.

−20°C

General description

Duolink® flowPLA Detection Kit contains detection oligonucleotides with a fluorophore (lex = 644 nm/lem = 669 nm).

Application

Based on proximity ligation assay (PLA), the Duolink® PLA Technology allows for endogenous detection of protein interactions, post-translational modifications, and protein expression levels at the single molecule level in fixed cells.

Duolink® flowPLA Detection Kits will enable sensitive detection of proteins, protein-protein interactions, and protein modifications within cell populations by flow cytometry. To perform a Duolink® flowPLA experiment, you will need fixed, suspended cells, two primary antibodies that specifically recognize your proteins of interest, a pair of PLA probes (one 100RXN PLUS and one 100RXN MINUS), wash buffer, and a Duolink® flowPLA Detection Kit. The flowPLA Kits are available with 5 different fluorophores: Violet, Red, Green, Orange, or FarRed. The flowPLA Kits contain all the necessary reagents to perform the amplification and detection of bound PLA probes by flow cytometry. Analysis is carried out using standard flow cytometry assay equipment. User must provide a fixed cell suspension, primary antibodies, and corresponding PLA Probes.

Follow the Duolink® PLA Flow Cytometry Protocol to use this product.

Visit our Duolink® PLA Flow Cytometry page on how to run a Duolink® flow experiment, applications, troubleshooting, and more.

Application Note

Primary antibodies are needed. Test your primary antibodies (IgG-class, mono- or polyclonal) in a standard immunofluorescence (IF), immunohistochemistry (IHC), or immunocytochemistry (ICC) assay to determine the optimal fixation, blocking, and titer conditions. Flow validated antibodies are recommended.

Let us do the work for you, learn more about our Custom Service Program to accelerate your Duolink® projects

View full Duolink® product list
Duolink® flowPLA Detection Kit–FarRed has been used in in situ proximity ligation assay:
  • to detect interaction and complex formation between cellular retinoic acid binding protein 1 (Crabp1) and the components of rapidly accelerated fibrosarcoma (Raf) kinase- MAPK-Erk kinase (Mek) signaling pathway[1]
  • to study protein interaction in human cultured MOLT-4 cells and HeLa cells[2]
  • to visualize Beclin-1 protein interaction with 14-3-3t in neurons[3]
  • to study protein interactions in graft endothelial cells[4] 

Biochem/physiol Actions

Far Red Fluorescence Detection Reagents
Use appropriate laser for λex 644 nm excitation
Use appropriate filter for λem 669 nm emission

Features and Benefits

  • Analyze protein protein interactions with flow cytometry readout
  • Analyze cell populations with Proximity Ligation Assay
  • Increased sensitivity due to rolling circle amplification for low abundant targets
  • No overexpression or genetic manipulation required
  • Relative quantification possible
  • Works with any flow cytometer instrumentation
  • Easy to follow flexible protocol
  • Publication-ready results

Other Notes

This product is comprised of the following:
  • 5x Detection Solution - FarRed (DUO84004)
  • 5x Ligation Buffer (DUO82009)
  • 5x Amplification Buffer (DUO82050)
  • Ligase (1U/μL)
  • Polymerase (10U/μL)

See datasheet for more information.

Legal Information

Duolink is a registered trademark of Merck KGaA, Darmstadt, Germany
PLA is a registered trademark of Merck KGaA, Darmstadt, Germany

Comparar elementos similares

Ver comparación completa

Mostrar Diferencias

1 of 1

Este artículo
DUO94001DUO94003DUO94002
suitability

suitable for fluorescence

suitability

suitable for fluorescence

suitability

suitable for fluorescence

suitability

suitable for fluorescence

fluorescence

λex 644 nm; λem 669 nm

fluorescence

λex 594 nm; λem 624 nm

fluorescence

λex 554 nm; λem 576 nm

fluorescence

λex 495 nm; λem 527 nm

technique(s)

flow cytometry: suitable, proximity ligation assay: suitable, immunofluorescence: suitable

technique(s)

flow cytometry: suitable, immunofluorescence: suitable, proximity ligation assay: suitable

technique(s)

flow cytometry: suitable, immunofluorescence: suitable, proximity ligation assay: suitable

technique(s)

flow cytometry: suitable, immunofluorescence: suitable, proximity ligation assay: suitable

product line

Duolink®

product line

Duolink®

product line

Duolink®

product line

Duolink®

shipped in

dry ice

shipped in

dry ice

shipped in

dry ice

shipped in

dry ice

storage temp.

−20°C

storage temp.

−20°C

storage temp.

−20°C

storage temp.

−20°C


pictograms

Health hazardEnvironment

signalword

Danger

Hazard Classifications

Aquatic Chronic 2 - ED ENV 1 - Resp. Sens. 1

Clase de almacenamiento

10 - Combustible liquids

wgk

WGK 3



Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos


Artículos

Considerations for proper experimental design, preparation and execution of the Duolink® PLA for flow cytometry protocol.

General tips and tricks for proper experiment execution, aid in identifying potential problems, and provide solutions to ensure a successful Duolink® PLA experiment for flow cytometry.

Duolink® PLA kit enhances flow cytometry for detecting protein interactions accurately.

Ver todos los artículos

Tyler J Burns et al.
Cytometry. Part A : the journal of the International Society for Analytical Cytology, 91(2), 180-189 (2017-01-18)
To quantify visual and spatial information in single cells with a throughput of thousands of cells per second, we developed Subcellular Localization Assay (SLA). This adaptation of Proximity Ligation Assay expands the capabilities of flow cytometry to include data relating
Sofie Selmer Andersen et al.
Cytokine, 64(1), 54-57 (2013-06-04)
Many cytokine receptors are cell surface proteins that promiscuously combine to form active signalling homo- or heterodimers. Thus, receptor chain dimerization can be viewed as a direct measure of a high probability of intracellular signalling by specific cytokines. Proximity ligation
Sung Wook Park et al.
Scientific reports, 9(1), 10929-10929 (2019-07-31)
The rapidly accelerated fibrosarcoma (Raf) kinase is canonically activated by growth factors that regulate multiple cellular processes. In this kinase cascade Raf activation ultimately results in extracellular regulated kinase 1/2 (Erk1/2) activation, which requires Ras binding to the Ras binding



Número de artículo de comercio global

SKUGTIN
DUO94004-40TST04061835515844

Questions

1–3 of 3 Questions  
  1. Is it possible to just buy the 5x Detection Solution separately?

    1 answer
    1. Unfortunately, the kit components are not sold separately.

      Helpful?

  2. Can I use this kit in conjunction with staining for other markers? If so, would you recommend staining with the PLA kit first, followed by staining with other primary-conjugated antibodies?

    1 answer
    1. It is possible to counterstain after the Duolink in situ amplification. It is recommended to apply the counterstaining protocol after the completion of the Amplification step in section 7.3, step 5 of the Duolink In Situ Fluorescence User Manual.

      Please see the protocol below:
      https://www.sigmaaldrich.com/technical-documents/protocol/protein-biology/protein-and-nucleic-acid-interactions/duolink-counterstain

      Helpful?

  3. Hello, can I also dilute the 5 x detection stock in something else than high purity water? Maybe PBS?

    1 answer
    1. It is not recommended to use any other solvent to dilute the 5x detection stock due to the sensitivity of this reaction. The Duolink kits have been optimized for use under the conditions described. Deviation from the protocol may not offer the best results. Please see the link below to view the full product information for the Duolink PLAFlow kits:
      https://www.sigmaaldrich.com/technical-documents/technical-article/protein-biology/protein-and-nucleic-acid-interactions/duolink-pla-flow-cytometry-kits