Saltar al contenido
MilliporeSigma

Saltar a

57330-U

Portafibra SPME

greener alternative

for use with Manual Sampling, pk of 1

Sinónimos:

Portafibra de microextracción de fase sólida

Iniciar sesión para ver los precios por organización y contrato.

Seleccione un Tamaño

Cambiar Vistas
Tamaño de envaseSKUDisponibilidadPrecio
1 ea
Comprobar disponibilidad del carrito
$766.00

Acerca de este artículo

NACRES:
NB.21
UNSPSC Code:
41115724

$766.00


Comprobar disponibilidad del carrito

Solicite una orden a granel
Servicio técnico
¿Necesita ayuda? Nuestro equipo de científicos experimentados está aquí para ayudarle.
Permítanos ayudarle


packaging

pk of 1

Quality Level

greener alternative product characteristics

Waste Prevention
Safer Solvents and Auxiliaries
Learn more about the Principles of Green Chemistry.

sustainability

Greener Alternative Product

technique(s)

solid phase microextraction (SPME): suitable

compatibility

for use with Manual Sampling

greener alternative category

General description

El soporte protege la fibra revestida y controla la exposición de la fibra durante la adsorción y la desorción del analito. El soporte es reutilizable indefinidamente y acepta la fibra sustituible. Los usuarios nuevos deben pedir un soporte y un conjunto de fibra.

Portafibras para muestreo manual

Una guía de profundidad ajustable orienta la fibra para muestreo y para la colocación correcta en la zona caliente del puerto de inyección de la GC. La fibra puede bloquearse en la posición expuesta.

Portafibras para muestreo automático o análisis mediante HPLC

Utilice este portafibras con un automuestreador Varian 8100/8200 o con nuestra interfaz SPME/HPLC. Se necesita un kit de actualización de SPME para trabajar con el automuestreador Varian. Si desea información concerniente a los requisitos del sistema, póngase en contacto con la división Varian Instrument.

Portafibras para CTC CombiPAL/CombiPAL-xt y Gerstel MPS2
Nos hemos comprometido a proporcionarle los productos alternativos más sostenibles, que se adhieran a uno o más de los 12 principios de la química sostenible. Este es un producto de tecnología de microextracción en fase sólida (SPME). La SPME es una de las tecnologías más ecológicas para la preparación de muestras, ya que es una tecnología de extracción sin disolventes y las fibras de SPME son reutilizables y generan la menor cantidad de residuos posible, por lo que se alinea con "Prevención de residuos" y "Disolventes y auxiliares más seguros". Pulse aquí si desea más información.

Application

The SPME Fiber Holder is designed for manual sampling, allowing precise control over the extraction process. It facilitates the integration of sampling, extraction, concentration, and sample introduction into a single solvent-free step. This reduces the need for complex, multi-step procedures and minimizes the use of organic solvents. The holder is compatible with various fiber coatings, making it suitable for a wide range of analytical applications.

Comparar elementos similares

Ver comparación completa

Mostrar Diferencias

1 of 1

Este artículo
5733157356-U57347-U
sustainability

Greener Alternative Product

sustainability

Greener Alternative Product

sustainability

Greener Alternative Product

sustainability

Greener Alternative Product

compatibility

for use with Manual Sampling

compatibility

for use with Non-CTC CombiPAL Type Autosamplers

compatibility

-

compatibility

for use with CTC CombiPAL, Gerstel MPS2 Autosamplers

greener alternative category

Aligned,

greener alternative category

, Aligned

greener alternative category

, Aligned

greener alternative category

, Aligned

packaging

pk of 1

packaging

pk of 1

packaging

-

packaging

pk of 1

technique(s)

solid phase microextraction (SPME): suitable

technique(s)

solid phase microextraction (SPME): suitable

technique(s)

solid phase microextraction (SPME): suitable

technique(s)

solid phase microextraction (SPME): suitable

Quality Level

100

Quality Level

-

Quality Level

100

Quality Level

100


Still not finding the right product?

Explore all of our products under Portafibra SPME




Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documentos section.

Si necesita más asistencia, póngase en contacto con Atención al cliente

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos


Protocolos

Se probaron el alto rendimiento, la fiabilidad y la reproducibilidad de la microextracción en fase sólida en espacio de cabeza (HS-SPME) en combinación con cromatografía de gases/espectrometría de masas (GC/MS) para la determinación de los compuestos orgánicos volátiles (COV) en agua en un ensayo interlaboratorio. La nueva ISO 17943 en la que se utiliza HS-SPME supone una mejora de los métodos oficiales existentes para esta determinación en cuanto a sensibilidad y selectividad.

High performance, reliability, and reproducibility of HS-SPME in combination with GC/MS for the determination of VOCs in water was proven in an interlaboratory trial. The new ISO 17943 using HS-SPME is an improvement on existing official methods for this determination in terms of sensitivity and selectivity.

SPME enables rapid, sensitive GC/MS analysis of residual solvents in hemp extract, ensuring accuracy and efficiency.

Ver todos los protocolos

Artículos

A throughput HS-SPME-GC-MS method to analyze volatile compounds in Perilla leaves at low extraction temperatures using four different SPME fibers.

The work describes the development of an HS-SPME-GC-MS method to determine 2-chloroethanol as a marker of fumigant ethylene oxide in different kinds of sesame seed samples.

A direct immersion SPME method using a new overcoated SPME fiber was developed for the extraction of pesticides from pureed prune baby food.

Ver todos los artículos

Contenido relacionado

Solid phase microextraction (SPME) is a solvent-free sample preparation technique that uses coated fibers to extract analytes of interest from a sample before analysis by GC or HPLC.

La microextracción en fase sólida (SPME) es una técnica de preparación de muestras sin disolvente en la que se utilizan fibras recubiertas para extraer analitos de interés de una muestra antes del análisis mediante GC o HPLC.


Na Li et al.
Food chemistry, 332, 127426-127426 (2020-07-04)
A selected Pichia fermentans strain was simultaneously and sequentially inoculated in synthetic and real juice with S. cerevisiae strains of different antagonistic activities in a ratio 1:1 to observe the correlation between varietal odorants and glycosidase activities. Fermentations using pure
Edited by Sue Ann Scheppers Wercinski
Solid Phase Microextraction: A Practical Guide, 257-257 (1999)
Pawliszyn, Janusz
Solid Phase Microextraction: Theory and Practice, 264-264 (1997)



Número de artículo de comercio global

SKUGTIN
57330-U04061835552931
Y000219404065265653121

Questions

1–6 of 6 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  3. What GC injection septa should be used when using the SPME Fiber Holder, Product 57330-U?

    1 answer
    1. We recommend the use of molded Thermogreen LB-2 septa with an injection hole.

      Helpful?

  4. Can I put the SPME Fiber Holder, Product 57330-U, in the oven for conditioning?

    1 answer
    1. No, the barrel is made of a black polymeric material and it will melt.

      Helpful?

  5. Can I use the SPME Fiber Holder, Product 57330-U, with any GC model?

    1 answer
    1. This SPME holder is designed to be used with manually with any GC having an appropriate, straight inlet liner.

      Helpful?

  6. What is the Department of Transportation shipping information for this product?

    1 answer
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      Helpful?

Reviews

No rating value

Active Filters