[Skip to Content](https://www.sigmaaldrich.com#main-content) [![Merck](https://www.sigmaaldrich.com/static/logos/purple/merck.svg)](https://www.sigmaaldrich.com/VN/en) Products Cart0 VNEN Products ProductsApplicationsServicesResourcesSupport [Login / Register](https://www.sigmaaldrich.com/oidc-sign-in) [Order Lookup](https://www.sigmaaldrich.com/VN/en/order-lookup) [Quick Order](https://www.sigmaaldrich.com/VN/en/quick-order) Cart0 [Home](https://www.sigmaaldrich.com/VN/en)[Solid Phase Extraction (SPE)](https://www.sigmaaldrich.com/VN/en/applications/analytical-chemistry/sample-preparation/solid-phase-extraction)HybridSPE®-Phospholipid Technology # HybridSPE®-Phospholipid Technology ## Effective Removal of Phospholipids and Proteins for Accurate and Reproducible LC-MS Analysis __Section Overview__ [Impact of Phospholipids on Accuracy and Reproducibility of LC-MS Data](https://www.sigmaaldrich.com#accuracy) [Limitations of Traditional Sample Prep Methodologies for Biological Samples](https://www.sigmaaldrich.com#limits) [The Unique Chemistry and Basic Methodology of HybridSPE®-phospholipids Technology](https://www.sigmaaldrich.com#Chemistry) ## HybridSPE®-PLus Plates - the Next Generation in HybridSPE®-Phospholipid Technology Our new HybridSPE®-PLus plates offer the same time-proven chemistry of our traditional HybridSPE®-Phospholipid plates coupled with plate manufacturing enhancements that stem from years of production experience. These manufacturing enhancements have allowed us to increase well-to-well flow consistency and reduce sample  hold-up volumes, further improving analyte recoveries and assay reproducibility. We will continue to offer and support our traditional square-well HybridSPE®-Phospholipid plates for those customers who have developed methods on them, but we invite those customers developing new methods to take advantage of the newest technology: HybridSPE®-PLus. ## [](https://www.sigmaaldrich.com)Impact of Phospholipids on Accuracy and Reproducibility of LC-MS Data __Phospholipids: A Concern for LC-MS Analysis of Small Molecules in Biological Matrices__ Phospholipids are present as a major component of all cell membranes. They are therefore present in all biological sample matrices including serum, plasma and whole blood and can be a problem in LC-MS analysis of small molecules because they often co-elute and ionize along with the analytes of interest. This co-elution results in ion suppression (an erroneous decrease) of the mass spec signal that can cause variability and impact LC-MS result accuracy (__Figure 1__). ![Phospholipid Effect on Ionization of Clonidine](https://www.sigmaaldrich.com/content/dam/cms-commons/sigmaaldrich/marketing/global/images/technical-documents/articles/analytical-chemistry/solid-phase-extraction/t409095-fig-1.gif "Phospholipid Effect on Ionization of Clonidine") __Figure 1.__ Phospholipid Effect on Ionization of Clonidine ### Importance of Accurate Results and Fast Answers in Bioanalysis We understand that the results of your analyses can have a significant impact on the lives of many others. This puts pressure on you to ensure the data you produce is as accurate as possible. Not only do you need quick answers, you need answers you can trust. The complexity of the types of samples with which you work does not make your job any easier. Proteins and phospholipids inherently present, to varying degrees in your samples, can add variability to your analytical results when using sensitive techniques such as LC-MS or LC-MS/MS. We have over four decades of chromatography expertise to help you navigate the complexity of your sample prep options. ## [](https://www.sigmaaldrich.com)Limitations of Traditional Sample Prep Methodologies for Biological Samples ### Limitations of Traditional Biological Sample Cleanup Methods Most clinical and biological researchers use traditional methods such as protein precipitation and liquid-liquid extraction to cleanup their samples prior to analysis. While these techniques allow for inexpensive and quick removal of proteins, they completely fail to address the problem of phospholipid-induced ion suppression. Even if phospholipids do not co-elute with the analyte of interest, they can accumulate on your analytical column and elute from the column sporadically in downstream analyses. This can cause unpredictable ion suppression and poor reproducibility, thereby putting the accuracy of your results at risk (__Figure 2__). Background Interference Observed after Multiple Injections Using Std. Protein PPT ![Gradient RP LC-MS of Blank Plasma Samples](https://www.sigmaaldrich.com/content/dam/cms-commons/sigmaaldrich/marketing/global/images/technical-documents/articles/analytical-chemistry/solid-phase-extraction/t409095-fig-2A.gif "Gradient RP LC-MS of Blank Plasma Samples") __Figure 2.__ Gradient RP LC-MS of Blank Plasma Samples Prepared by Standard Protein PPT vs. HybridSPE®-Phospholipid Background Interference Observed after Multiple Injections Using HybridSPE®-Phospolipid Technology ![HybridSPE®-Phospolipid Technology](https://www.sigmaaldrich.com/content/dam/cms-commons/sigmaaldrich/marketing/global/images/technical-documents/articles/analytical-chemistry/solid-phase-extraction/t409095-fig-2B.gif "HybridSPE®-Phospolipid Technology") Back Pressure Generated Within C18 1.8 µm Column (5 cm x 2.1 mm) after Multiple Injections ![Back Pressure Generated Within C18 1.8 µm Column (5 cm x 2.1 mm) after Multiple Injections](https://www.sigmaaldrich.com/content/dam/cms-commons/sigmaaldrich/marketing/global/images/technical-documents/articles/analytical-chemistry/solid-phase-extraction/t409095-fig-2C.gif "Back Pressure Generated Within C18 1.8 µm Column (5 cm x 2.1 mm) after Multiple Injections") ### Phospholipid Removal Techniques To overcome the problem of phospholipid-induced ion suppression, some analysts try traditional SPE. Traditional SPE often requires time-consuming and complex method development, but still only removes nominal amounts of phospholipids. Remaining phospholipids can impact the accuracy of your results, accumulate on your analytical column to impact future analyses, add to column replacement costs and increase instrument downtime. A variety of products designed specifically for the removal of both proteins and phospholipids are now commercially available, including HybridSPE® plates and cartridges. Most of these products are simple, fast and easy-to-use, offering fairly standardized methods with minimal method development. Most, however, use a hydrophobic retention mechanism to separate phospholipids from analytes of interest in the sample. This poses a problem if the analytes of interest are also hydrophobic because they will be retained and removed along with the hydrophobic phospholipids. This results in decreased analyte recovery and inaccurate results. HybridSPE®Phospholipid Technology is different in that it completely removes both proteins and phospholipids from the sample without retaining other hydrophobic compounds. ## [](https://www.sigmaaldrich.com)The Unique Chemistry and Basic Methodology of HybridSPE®-Phospolipid Technology __How Is HybridSPE®-Phospholipid Technology Different Than Other Phospholipid Removal Products?__ The first of its kind, HybridSPE®-Phospholipid technology was introduced in 2008. It fuses the simple, standardized methodology of traditional protein precipitation with the specificity of [solid phase extraction](https://www.sigmaaldrich.com/VN/en/products/analytical-chemistry/analytical-sample-preparation/spe-and-quechers) (SPE) for the simultaneous removal of proteins and phospholipids from biological samples prior to LC-MS analysis. Unlike other phospholipid removal products that use a hydrophobic retention mechanism to remove phospholipids from biological samples, HybridSPE®-Phospholipid technology uses a unique retention mechanism (__Figure 3__). This allows it to separate phospholipids from even very hydrophobic analytes, such as vitamins which are often retained along with phospholipids on competitive products. ![Unique Retention Mechanism of HybridSPE®-Phospholipid Technology](https://www.sigmaaldrich.com/content/dam/cms-commons/sigmaaldrich/marketing/global/images/technical-documents/articles/analytical-chemistry/solid-phase-extraction/t409095-fig-3.gif "LOP 11832_HybridSPE Brochure.indd") __Figure 3.__ Unique Retention Mechanism of HybridSPE®-Phospholipid Technology Allows for Separation of Even Very Hydrophobic Analytes from Phospholipid Contaminants in Biological Sample Matrices __A Newer, Better “Go-to” Sample Prep Method for Phospholipid Removal__ Labs working with biological samples often choose to perform protein precipitation prior to LC-MS analysis, using it as their “go-to” sample prep method. They view phospholipid removal as more costly, more time-consuming and unnecessary if the specific analytes of interest do not co-elute with the phospholipids in their sample. This is not the case. Labs can actually reduce overall costs and increase overall throughput while generating more accurate data by using HybridSPE®-Phospholipid technology to remove both proteins and phospholipids from all biological samples prior to small molecule LC-MS analysis. __Simple and Fast Phospholipid Removal__ The 96-well plate protocol involves just a few simple steps (__Figures 4 and 5__), and plates can be used right out of the package with no pre-conditioning step required. The sample (containing internal standards if desired) and a precipitation solvent are first added to the well plate, followed by a mixing step and vacuum application to collect the sample. Collected samples are then ready to be analyzed. ![Depiction of Basic HybridSPE®-Phospholipid Sample Prep Workflow](https://www.sigmaaldrich.com/content/dam/cms-commons/sigmaaldrich/marketing/global/images/technical-documents/articles/analytical-chemistry/solid-phase-extraction/t409095-fig-4.jpg "LOP 11832_HybridSPE Brochure.indd") __Figure 4.__ Depiction of Basic HybridSPE®-Phospholipid Sample Prep Workflow 1\. __Add Sample__ Pipette 100 µL plasma or serum to the HybridSPE® plate followed by 300 µL precipitation solvent. Add internal standards as necessary. 2\. __Mix__ by vortexing/shaking HybridSPE® plate or by aspirating/dispensing with 0.5–1 mL pipette tip. 3\. __Apply vacuum__ The packed-bed filter/frit assembly acts as adepth filter for the concurrent physical removal of precipitated proteins and chemical removal of phospholipids. Small molecules (e.g., pharma compounds and metabolites) pass through unretained. 4\. __Collect Sample__ Resulting filtrate/eluate is free of proteins and phospholipids and ready for immediate LC-MS/MS analysis. ![HybridSPE® 96-well Plate Protocol](https://www.sigmaaldrich.com/content/dam/cms-commons/sigmaaldrich/marketing/global/images/technical-documents/articles/analytical-chemistry/solid-phase-extraction/t409095-fig-5.jpg "LOP 11832_HybridSPE Brochure.indd") __Figure 5.__ HybridSPE® 96-well Plate Protocol ### Technical Resources Category / TitleTypeSize (kb)No. PagesI.D. [Instructions for HybridSPE®-PLus 96-Well Plates](https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/113/472/T713202_HybridSPE-PLus.pdf.pdf)Data Sheet1052T713202 [Instructions & Troubleshooting for HybridSPE®-Phospholipid Ultra Cartridge](https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/213/509/T710124.pdf.pdf)Data Sheet3502T710124 Investigating Matrix Interference in Analysis of Antiarrhythmic Cardiac Drugs in Plasma (Reporter 31.1)Article--- [Isolation and LC-MS Characterization of Illicit Bath Salts in Urine (Reporter 30.3)](https://www.sigmaaldrich.com/language-masters/en/technical-documents/technical-article/analytical-chemistry/solid-phase-extraction/lc-ms-bath-saltsurine)Article--- [Meeting the LC-MS Needs of a High-Throughput Clinical Lab](http://www.bioanalysis-zone.com/webinars/meeting-the-lc-ms-needs-of-a-high-throughput-clinical-laboratory/) (60 min; Bioanalysis Zone recorded webinar; registration required)Webinar--- [HybridSPE®-Precipitation Technology](https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/159/852/t408102.pdf.pdf)Product Info.4832T408102 [Enrichment of Phospholipids in Biological Samples Using HybridSPE®](https://www.sigmaaldrich.com/VN/en/technical-documents/protocol/analytical-chemistry/solid-phase-extraction/enrichment-of-phospholipids) (Reporter 28.3)Article--T210003 Minimizing Phospholipid Matrix Effects in HILIC LC-MS using HybridSPE®-Precipitation Small Volume Plates (Reporter 28.2)Article--T210002 Increased Bioanalytical Throughput and Recovery Utilizing HybridSPE®-PPT Small Volume Plates (Reporter 28.1)Article--T210001 Troubleshooting Analyte Recovery when Using HybridSPE®-Precipitation Technology (Reporter 27.2)Article--T209002 Increase Bioanalytical Assay Speed via Phospholipid Removal using HybridSPE™-Precipitation Technology (Reporter 26.5)Article--T208005 [High Recovery Method of HybridSPE®-Phospholipid for Cleanup of Biological Samples Prior to LC-MS Analysis](https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/242/823/t411056h.pdf.pdf)Presentation46522T411056H [High Throughput Bioanalysis Utilizing Fused-Core™ Particle and HybridSPE®-PPT Technology (HPLC 2010)](https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/144/702/t410086h.pdf.pdf)Presentation49419T410086H [Alternative Method of Hybrid SPE Sample Preparation for High Recovery LC-MS Analysis of Pharmaceutical Compounds in Plasma](https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/275/203/t409228h.pdf.pdf)Presentation71217T409228H [Comparison of Sample Preparation Techniques for Reduction of Matrix Interference in Biological Analysis by LC-MS-MS](https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/382/672/t408163h.pdf.pdf)Presentation21622T408163H [Depletion of Phospholipid Matrix Interference when Dealing with Small Volume Plasma Samples](https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/245/858/t410128h.pdf.pdf)Presentation58720T410128H [High Throughput Removal of Both Phospholipids and Proteins in Bioanalytical Sample Preparation](https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/947/310/t409038h.pdf.pdf)Presentation25720T409038H [Impact of Ion-Suppression Due to the Presence of Phospholipids on the Enantiomeric LC-MS Analysis of Clenbuterol](https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/125/389/t409108h.pdf.pdf)Presentation18517T409108H [Increased Bioanalytical Throughput Utilizing Fused-Core™ Particles with Selective Phospholipid Depletion](https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/313/876/t409189h.pdf.pdf)Presentation53221T409189H [Recovery of Pharmaceutical Drugs From Small Volume Biological Sample Using HybridSPE®-PPT 96-well Plate](https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/127/398/t410048h.pdf.pdf)Presentation64622T410048H [Selective Depletion of Phospholipids Interference Utilizing HybridSPE™-Precipitation Technology](https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/291/976/t408181h.pdf.pdf)Presentation65849T408181H __Related Articles__ - [Determination of Formaldehyde and Acetaldehyde in Air Using DNPH Cartridges and Automated On-Line Desorption Followed by HPLC](https://www.sigmaaldrich.com/VN/en/technical-documents/protocol/environmental-testing-and-industrial-hygiene/air-testing/aldehydes-air-dnph) - [Effect of Container Materials on Milk Off-Flavors](https://www.sigmaaldrich.com/VN/en/technical-documents/technical-article/analytical-chemistry/gas-chromatography/container-materials) - [Pesticide Residue Analysis in Ginger Powder with QuEChERS](https://www.sigmaaldrich.com/VN/en/technical-documents/technical-article/analytical-chemistry/quechers/analysis-of-pesticide-residues-in-ginger-powder) - [Analysis of Pesticide Residues in Pistachios Using QuEChERS Extraction and Cleanup with Supel™ QuE Z-Sep+](https://www.sigmaaldrich.com/VN/en/technical-documents/technical-article/analytical-chemistry/quechers/analysis-of-pesticide-residues-in-pistachios) - [HybridSPE-Phospholipid Technology](https://www.sigmaaldrich.com/VN/en/technical-documents/technical-article/analytical-chemistry/small-molecule-hplc/hybridspe-precipitation-technology) - [Solvent Analysis for 40 Per and Polyfluoroalkyl Substances](https://www.sigmaaldrich.com/VN/en/technical-documents/technical-article/analytical-chemistry/small-molecule-hplc/solvent-analysis-for-40-per-and-polyfluoroalkyl-substances) - [Analysis of Drugs of Abuse in Urine](https://www.sigmaaldrich.com/VN/en/technical-documents/technical-article/analytical-chemistry/solid-phase-extraction/analysis-of-drugs-of-abuse-in-urine-after-cleanup-with-hlb) - [LC-MS Analysis of Warfarin™ in Plasma Samples](https://www.sigmaaldrich.com/VN/en/technical-documents/technical-article/analytical-chemistry/solid-phase-extraction/chiral-and-achiral-lc-ms-analysis-of-warfarin-in-plasma-samples) - [View More](https://www.sigmaaldrich.com/VN/en/search/facet-search?focus=sitecontent&term=facet-search) Top __Sign In To Continue__ To continue reading please sign in or create an account. Sign In__Don't Have An Account?__Register Support[Customer Support](https://www.sigmaaldrich.com/VN/en/support/customer-support)[Contact Us](https://www.sigmaaldrich.com/VN/en/collections/offices)[FAQ](https://maestro.my.site.com/knowledgeportal/s/)[Safety Data Sheets (SDS)](https://www.sigmaaldrich.com/VN/en/documents-search?tab=sds)[Certificates (COA/COO)](https://www.sigmaaldrich.com/VN/en/documents-search?tab=coa)[Quality & Regulatory](https://www.sigmaaldrich.com/VN/en/life-science/quality-and-regulatory-management)[Calculators & Apps](https://www.sigmaaldrich.com/VN/en/support/calculators-and-apps)[Webinars](https://www.sigmaaldrich.com/VN/en/collections/webinars) Orders[Order Lookup](https://www.sigmaaldrich.com/VN/en/order-lookup)[Quick Order](https://www.sigmaaldrich.com/VN/en/quick-order)[Custom Products](https://www.sigmaaldrich.com/VN/en/services/custom-products)[eCommerce Solutions](https://www.sigmaaldrich.com/VN/en/life-science/ecommerce/ecommerce-solutions) Company[About Us](https://www.sigmaaldrich.com/VN/en/life-science/about-us)[Responsibility](https://www.sigmaaldrich.com/VN/en/life-science/ssbi)[Events](https://www.sigmaaldrich.com/VN/en/collections/events)[Press Releases](https://www.sigmaaldrich.com/VN/en/collections/press)[Programs](https://www.sigmaaldrich.com/VN/en/life-science/partnership-programs)[Careers](https://careers.merckgroup.com/global/en)[Offices](https://www.sigmaaldrich.com/VN/en/collections/offices) Social Media [![LinkedIn icon](https://www.sigmaaldrich.com/content/dam/cms-commons/sigmaaldrich/marketing/global/images/icons/linkedin.svg)](https://www.linkedin.com/company/merck-life-science) [![X icon](https://www.sigmaaldrich.com/content/dam/cms-commons/sigmaaldrich/marketing/global/images/icons/x-icon.svg)](https://x.com/Merck_lifesci) [![Facebook Icon](https://www.sigmaaldrich.com/content/dam/cms-commons/sigmaaldrich/marketing/global/images/icons/facebook.svg)](https://www.facebook.com/Merck.lifescience) [![Instagram Icon](https://www.sigmaaldrich.com/content/dam/cms-commons/sigmaaldrich/marketing/global/images/icons/instagram.svg)](https://www.instagram.com/mercklifescience/) [![YouTube Icon](https://www.sigmaaldrich.com/content/dam/cms-commons/sigmaaldrich/marketing/global/images/icons/youtube.svg)](https://www.youtube.com/@MerckLifeScience/featured) Merck __Research. Development. Production.__ We are a leading supplier to the global Life Science industry with solutions and services for research, biotechnology development and production, and pharmaceutical drug therapy development and production. [![Vibrant M string](https://www.sigmaaldrich.com/content/dam/cms-commons/sigmaaldrich/marketing/global/images/icons/vibrant-m-string-1-rrvcrp.svg)](https://www.sigmaaldrich.com/VN/en) [Sigma-Aldrich® Solutions](https://www.sigmaaldrich.com/VN/en/life-science/sigma-aldrich)[BioReliance® Solutions](https://www.sigmaaldrich.com/VN/en/life-science/bioreliance)[Millipore® Solutions](https://www.sigmaaldrich.com/VN/en/life-science/millipore)[SAFC® Solutions](https://www.sigmaaldrich.com/VN/en/life-science/safc)[Milli-Q® Solutions](https://www.sigmaaldrich.com/VN/en/life-science/milliq)[Supelco® Solutions](https://www.sigmaaldrich.com/VN/en/life-science/supelco) © 2026 Merck KGaA, Darmstadt, Germany and/or its affiliates. All Rights Reserved, including Text and Data Mining for AI training and similar technologies. Reproduction of any materials from the site is strictly forbidden without permission. [Site Use Terms](https://www.sigmaaldrich.com/VN/en/life-science/legal/site-use-terms)|[Privacy Policy](https://www.sigmaaldrich.com/VN/en/life-science/legal/privacy-statement)|[General Terms and Conditions of Sale](https://www.sigmaaldrich.com/VN/en/life-science/legal/terms-and-conditions)|[Copyright Consent](https://www.sigmaaldrich.com/VN/en/life-science/legal/copyright-consent) |[Site Map](https://www.sigmaaldrich.com/VN/en/site-map) __CÔNG TY TNHH MERCK VIỆT NAM__ Trụ sở chính: Tầng 21, Tòa nhà Ngôi nhà Đức, số 33, đường Lê Duẩn, Phường Sài Gòn, Thành phố Hồ Chí Minh, Việt Nam Mã số doanh nghiệp: 0309785593 Cấp bởi Sở Tài Chính Thành Phố Hồ Chí Minh - Phòng Đăng Ký Kinh Doanh Đăng ký lần đầu: ngày 19 tháng 01 năm 2010 Đăng ký thay đổi lần thứ: 13, ngày 17 tháng 06 năm 2026 Điện thoại: +84 28 3842 0100 [![VN Footer Logo](https://www.sigmaaldrich.com/static/VN_footer_logo.png)](http://online.gov.vn/Home/WebDetails/95755)