Skip to Content
Merck

NA1020

GenElute PCR Clean-Up Kit

sufficient for 70 purifications

GenElute™ PCR Clean-Up Kit

Synonym(s):

Gen Elute, PCR Purification

Sign In to View Organizational & Contract Pricing.

Select a Size

1 KIT

R 3,316.32

R 3,316.32

List PriceR 3,384.00

Please contact Customer Service for Availability


About This Item

NACRES:
NA.52
UNSPSC Code:
41106300

Skip To

Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist

usage

sufficient for 70 purifications

technique(s)

DNA purification: suitable

Quality Level

input

DNA (single or double stranded PCR ampliflied)

test parameters

sample volume: 10 μg, sample volume: 100 μL

storage temp.

15-25°C

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
NA1111NA9604G1N10
usage

sufficient for 70 purifications

usage

sufficient for 70 purifications

usage

sufficient for 4 96-well plate purifications

usage

sufficient for 10 purifications

technique(s)

DNA purification: suitable

technique(s)

DNA purification: suitable

technique(s)

DNA purification: suitable

technique(s)

-

PCR9601

-

NA0150, NA0150S, NA0160

G1N350, G1N70, G1N9602, G1N9604

storage temp.

15-25°C

storage temp.

15-25°C

storage temp.

15-25°C

storage temp.

15-25°C

Quality Level

200

Quality Level

200

Quality Level

200

Quality Level

200

General description

The GenElute PCR Clean-Up Kit is designed for rapid purification of single-stranded or double-stranded PCR amplification products (100 bp to 10 kb) from other components in the reaction, such as excess primers, nucleotides, DNA polymerase, oil and salts. This kit combines the advantages of silica binding with a convenient spin column format, eliminating the need for expensive resins or toxic organic compounds such as phenol and chloroform.

DNA is bound on a silica membrane within the spin column. The bound DNA is washed and the clean, concentrated DNA is eluted in the buffer of choice. Each column can purify up to 100 μL or 10 μg of PCR amplified DNA and recover up to 95% of PCR products between 100 bp and 10 kb. More than 99% of the primers and most primer-dimers (<40 bp) are removed.

Purified DNA can be used in enzymatic reactions, conventional or automated sequencing, cloning and microarray analysis.

Application

GenElute PCR Clean-Up Kit has been used for rapid purification of single-stranded or double-stranded PCR amplification products (100bp to 10kb) from other components in the reaction.[1][2][3]
Purified DNA can be used in enzymatic reactions, conventional or automated sequencing, cloning and microarray analysis.

Biochem/physiol Actions

The GenElute PCR Clean-Up Kit combines the advantages of silica binding with a microspin format. The DNA is bound on a silica membrane within the spin column. The bound DNA is washed and the clean, concentrated DNA is eluted in the buffer of choice. Each column can purify up to 100 μL or 10 μg of PCR amplified DNA and recover up to 95% of PCR products between 100 bp and 10 kb. More than 99% of the primers and most primer-dimers (<40 bp are removed).

Features and Benefits

  • Purifies up to 100 μl or 10 μg of PCR amplified DNA in 8 minutes
  • Recovers up to 95% of PCR products between 100 bp and 10 kb
  • Removes over 99% of primers and other components
  • Eliminates the need to remove mineral oil by organic extraction
  • 40% more purification preps supplied than market leader
  • Recovers up to 95% of PCR products between 100 bp and 10 kb
  • Purifies up to 100 μL or 10 μg of PCR amplified DNA in 8 minutes
  • Removes over 99% of primers and other components

Other Notes

The GenElute PCR Clean-Up Kit is designed for rapid purification of single-stranded or double-stranded PCR amplification products (100 bp to 10 kb) from other components in the reactions, such as excess primers, nucleotides, DNA polymerase, oil and salts. This kit combines the advantages of silica binding with a convenient spin column format, eliminating the need for expensive resins or toxic organic compounds such as phenol and chloroform.

Legal Information

GenElute is a trademark of Sigma-Aldrich Co. LLC

Kit Components Also Available Separately

Product No.
Description
SDS

  • C2112Column Preparation SolutionSDS

pictograms

CorrosionExclamation mark

signalword

Warning

Hazard Classifications

Acute Tox. 4 Oral - Eye Irrit. 2 - Met. Corr. 1 - Skin Irrit. 2 - STOT SE 3

target_organs

Central nervous system

flash_point_f

Not applicable

flash_point_c

Not applicable

wgk

WGK 2

Storage Class

10 - Combustible liquids


Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Kathleen Gärtner et al.
Retrovirology, 6, 32-32 (2009-04-08)
Foamy viruses (FVs) are the most genetically stable viruses of the retrovirus family. This is in contrast to the in vitro error rate found for recombinant FV reverse transcriptase (RT). To investigate the accuracy of FV genome copying in vivo
Najla Chabchoub et al.
The American journal of tropical medicine and hygiene, 80(1), 24-27 (2009-01-15)
Stool samples from 86 immunocompromised patients (51 human immunodeficiency virus (HIV)-infected patients and 35 patients with haematologic malignancies) were systematically screened for intestinal microspordiosis by microscopic examination and polymerase chain reaction (PCR) using universal primer V1/PMP2. Nine samples (10.5%) showed
Adriana P Rebelo et al.
Nucleic acids research, 37(20), 6701-6715 (2009-09-11)
To characterize the organization of mtDNA-protein complexes (known as nucleoids) in vivo, we have probed the mtDNA surface exposure using site-specific DNA methyltransferases targeted to the mitochondria. We have observed that DNA methyltransferases have different accessibility to different sites on
Isolation of disseminated neuroblastoma cells from bone marrow aspirates for pretreatment risk assessment by array comparative genomic hybridization.
Vandewoestyne M
International Journal of Cancer. Journal International Du Cancer, 130(5), 1098-1108 (2012)
Andreas Veith et al.
Frontiers in microbiology, 2, 37-37 (2011-07-13)
The sulfur oxygenase reductase (SOR) is the initial enzyme of the sulfur oxidation pathway in the thermoacidophilic Archaeon Acidianus ambivalens. The SOR catalyzes an oxygen-dependent sulfur disproportionation to H(2)S, sulfite and thiosulfate. The spherical, hollow, cytoplasmic enzyme is composed of

Articles

Extract-N-Amp kits extract and amplify genomic DNA, optimized for plant tissue without inhibition concerns.

Validate CRISPR gene editing experiments easily with Sigma-Aldrich® T7E1 mismatch detection kit, ensuring successful editing.

SeqPlex™-I WTA kit amplifies RNA for NGS, enabling genomic studies from limited samples.

Protocols

GenElute™ PCR Clean-up Kit rapidly purifies PCR products from excess components, ensuring clean samples for downstream applications.

SeqPlex DNA Amplification Kit enables NGS from small or degraded DNA quantities for whole genome amplification.

The Extract-N-Amp™ Tissue PCR Kit contains all the reagents needed to rapidly extract and amplify genomic DNA from mouse tails and other animal tissues, buccal swabs, hair shafts, and saliva.

Protocol extracts genomic DNA from blood cards, useful for limited DNA samples in amplification.

See All

Related Content

Tools for plasmid preparation, in vitro transcription, mRNA purification, and LNP formulation in mRNA-based vaccine and therapeutic development.

Questions

1–8 of 8 Questions  
  1. What is the elution buffer made of? As it can be replaced with water, is it just water that is provided?

    1 answer
    1. The specific composition of the elution buffer E7777 is considered proprietary. However it is a Tris-HCL solution without EDTA.

      Helpful?

  2. Does this kit remove proteins from PCR product?

    1 answer
    1. This is a post-pcr clean up kit. The single or double-stranded amplification products are bound to the silica membrane. Then all non-DNA material such as primers, nucleotides, and polymerase are washed away. Finally the purified product is eluted. Anything that isn't bound will be removed.

      Helpful?

  3. What is the Department of Transportation shipping information for this product?

    1 answer
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      Helpful?

  4. Can Product NA1020, GenElute™ PCR Clean-Up Kit, be used for isolation of PCR products labeled with digoxigenin?

    1 answer
    1. Although we have not tested the kit with digoxigenin-labeled PCR products specifically, it should be fine to use

      Helpful?

  5. Can Product No. NA1020, GenElute™ PCR Clean-Up Kit,  be used to clean up PCR products larger than 10 kb?

    1 answer
    1. We haven't tested anything bigger than 10 kb, but we would expect larger DNA to bind well.  That said, the bound DNA might be more difficult to elute.  Heating the elution solution to 60-65°C may help with elution.  Incubating a few minutes to allow the elution solution to soak into the binding matrix may also help.

      Helpful?

  6. When using Product No. NA1020, GenElute™ PCR Clean-Up Kit, what is the largest amount of PCR reaction sample that can be processed on one column?

    1 answer
    1. The upper limit on the PCR reaction volume that can be cleaned up is 100 μl. In that scenario, 500 μl of binding solution would be added for a total of 600 μl volume being applied to the column.

      Helpful?

  7. When using GenElute™ PCR Clean-Up Kit, Product No. NA1020, Can the amount of elution buffer be reduced in order to obtain a more concentrated eluate?

    1 answer
    1. One may indeed increase concentration by reducing elution volume, but we would not suggest going lower than 25-30 μl. One must keep in mind that if a volume of less than 50 μl is used (for example, 30 μl), the concentration will increase, but the total yield will also be reduced.

      Helpful?

  8. Can GenElute™ PCR Clean-Up Kit, Product NA1020, be used for isolation of labeled PCR products?

    1 answer
    1. This kit will work with labeled PCR products and no modifications to the standard protocol are needed.

      Helpful?

Reviews

Active Filters

  1. 1 Ratings-only review

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service