EMAIL THIS PAGE TO A FRIEND
O-004 Cerilliant

Oxymorphone solution

1.0 mg/mL in methanol, ampule of 1 mL, certified reference material

  • CAS Number 76-41-5

  • Empirical Formula (Hill Notation) C17H19NO4

  • Molecular Weight 301.34

  •  MDL number MFCD00079194

  •  PubChem Substance ID 329818813

Purchase

Properties

Related Categories Additional Standards, Analytical Standards, Analytical/Chromatography, Certified Reference Materials (CRMs), Certified Reference Materials from Cerilliant,
grade   certified reference material
InChI Key   UQCNKQCJZOAFTQ-ISWURRPUSA-N
feature   Snap-N-Spike®/Snap-N-Shoot®
packaging   ampule of 1 mL
drug control   Narcotic Licence Schedule A (Switzerland); estupefaciente (Spain); Decreto Lei 15/93: Tabela IA (Portugal)
concentration   1.0 mg/mL in methanol
application(s)   HPLC: suitable
  gas chromatography (GC): suitable
format   single component solution
storage temp.   2-8°C

Description

General description

A certified Snap-N-Spike® solution of oxymorphone suitable for use in a variety of GC/MS or LC/MS applications from pain prescription monitoring, clinical toxicology, and pharmaceutical research to forensic analysis and urine drug testing. Oxymorphone, sold under trade names such as Opana®, Numorphan®, and Numorphone, is an opiate analgesic indicated for the relief of moderate to severe pain.

Legal Information

Numorphan is a registered trademark of Endo Pharmaceuticals Inc.

Opana is a registered trademark of Endo Pharmaceuticals Inc.

Snap-N-Shoot is a registered trademark of Cerilliant Corporation

Snap-N-Spike is a registered trademark of Cerilliant Corporation

Safety & Documentation

Safety Information

Symbol 
Signal word 
Danger
Hazard statements 
Precautionary statements 
RIDADR 
UN1230 - class 3 - PG 2 - Methanol, solution
WGK Germany 
1
Flash Point(F) 
48.2 °F
Flash Point(C) 
9 °C

Documents

Certificate of Analysis

Protocols & Articles

Articles

LC-MS Analysis of Pain Management Opiates using Ascentis® Express Biphenyl

From our library of Articles, Sigma-Aldrich presents LC-MS Analysis of Pain Management Opiates using Ascentis® Express Biphenyl
Keywords: Chromatography, High performance liquid chromatography, Liquid chromatography mass spectrometry, Mass spectrometry, Pharmaceutical, Separation

LC-MS Anlaysis of Pain Managment Opiates on Ascentis® Express Biphenyl, 30 x 2.1 mm

From our library of Articles, Sigma-Aldrich presents LC-MS Anlaysis of Pain Managment Opiates on Ascentis® Express Biphenyl, 30 x 2.1 mm
Keywords: Chromatography, High performance liquid chromatography, Liquid chromatography mass spectrometry, Mass spectrometry, Pharmaceutical, Separation

LC/MS (TOF) Analysis of Drugs and Their Glucuronide Metabolites in Urine on Titan™ C18 after Solid Phase Extraction (SPE) using Supel™-Select SCX, β-Glucuronidase Enzyme Digestion

From our library of Articles, Sigma-Aldrich presents LC/MS (TOF) Analysis of Drugs and Their Glucuronide Metabolites in Urine on Titan™ C18 after Solid Phase Extraction (SPE) using Supel™-Select SCX, β-Glucuronidase Enzyme Digestion
Keywords: Analgesics, Anticonvulsants, Chromatography, Clinical, Digestions, High performance liquid chromatography, Mass spectrometry, Metabolites, Sample preparations, Solid phase extractions

Medication Monitoring Testing

Prescription monitoring requires accurate reference standards to ensure consistent and reliable results for drug confirmation and monitoring compliance.
Keywords: Anti-depressants, Anticonvulsants, Cardiovascular, Clinical, Controlled substances, Diabetes, Forensic, Gas chromatography, High performance liquid chromatography, Ion-exchange chromatography, Mass spectrometry, Metabolites, Pharmaceutical, Schizophrenia

Opiate Standards

Over the last decade, the prevalence of nonmedical prescription opioid and opiate use has increased worldwide and is the primary contributor to the global number of drug-related deaths. In the United...
Keywords: Controlled substances, Ion-exchange chromatography

Phenyl-Hexyl Vs Biphenyl Phase for Separation of Pain Management Opiates

Pain management drugs are among the most prescribed medications, and they are also the most abused class of prescription drugs1-2. Therefore, many states have enacted laws governing the prescription ...
Keywords: Chromatography, Clinical, Diffusion, High performance liquid chromatography, Ion Exchange, Liquid chromatography mass spectrometry, Mass spectrometry, Separation

UHPLC/MS of Drugs and Metabolites in Urine following Enzymatic Hydrolysis

β-D-Glucuronide glucuronosohydrolase enzymes, commonly shortened to β-glucuronidase, play an important role in the analysis of biological fluids for the presence of metabolites for drug screening and...
Craig Aurand, Supelco; Kristen Brown, Pennsylvania State University
Reporter US Volume 33.2
Keywords: Carbohydrate metabolism, Derivatizations, Digestions, Enzyme activity, High performance liquid chromatography, Liquid chromatography mass spectrometry, Mass spectrometry, Metabolism, Metabolites, Sample preparations, Separation, Solid phase extractions, Solvents

Peer-Reviewed Papers
15

References

Related Products

related product

Product #

Description

Add to Cart

N-111 Noroxymorphone-3-ß-D-glucuronide solution, 100 μg/mL in methanol: water (2:8), certified reference material, ampule of 1 mL
P-071 Pain Management Multi-component Opiate Mixture-13 solution, 100 μg/mL each component (10 μg/mL Fentanyl), ampule of 1.0 mL, certified reference material
H-097 6α/β-Hydroxyoxymorphone solution, 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material
H-098 6α/β-Hydroxyoxymorphone-D3 solution, 100 μg/mL in methanol, ampule of 1 mL, certified reference material
N-012 Noroxymorphone hydrochloride solution, 1.0 mg/mL in methanol: DMSO (80:20) (as free base), ampule of 1 mL, certified reference material
N-013 Noroxymorphone hydrochloride solution, 100 μg/mL in methanol (as free base), ampule of 1 mL, certified reference material
O-003 Oxymorphone-D3 solution, 100 μg/mL in methanol, ampule of 1 mL, certified reference material
O-019 Oxymorphone-D3 solution, 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material
O-030 Oxymorphone-3-β-D-glucuronide solution, 100 μg/mL in methanol: water (1:1), ampule of 1 mL, certified reference material
O-031 Oxymorphone-D3-3-β-D-glucuronide solution, 100 μg/mL in methanol: water (1:1), ampule of 1 mL, certified reference material
43917 SnapIT Ampule Opener, large, for 5-10ml, 10-15ml, 20-25ml ampoules

Technical Service:

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Bulk Ordering & Pricing:

Need larger quantities for your development, manufacturing or research applications?