• USA Home
  • N-031 - Norfentanyl oxalate solution

EMAIL THIS PAGE TO A FRIEND
N-031 Supelco

Norfentanyl oxalate solution

1.0 mg/mL in methanol (as free base), ampule of 1 mL, certified reference material, Cerilliant®

Purchase

Properties

Related Categories Additional Standards, Analgesics (non-opiates), Analytical Standards, Analytical/Chromatography, Certified Reference Materials (CRMs),
Quality Level   100
grade   certified reference material
feature   Snap-N-Spike®/Snap-N-Shoot®
packaging   ampule of 1 mL
mfr. no.   Cerilliant®
drug control   Narcotic Licence Schedule A (Switzerland)
concentration   1.0 mg/mL in methanol (as free base)
Featured Industry   Pharmaceutical (small molecule)
format   single component solution
storage temp.   −20°C
SMILES string   OC(=O)C(O)=O.CCC(=O)N(C1CCNCC1)c2ccccc2
InChI   1S/C14H20N2O.C2H2O4/c1-2-14(17)16(12-6-4-3-5-7-12)13-8-10-15-11-9-13;3-1(4)2(5)6/h3-7,13,15H,2,8-11H2,1H3;(H,3,4)(H,5,6)
InChI key   OLFNESLXXQCODF-UHFFFAOYSA-N

Description

General description

Norfentanyl is a major urinary metabolite of fentanyl, a potent synthetic analgesic sold under various trade names including Sublimaze, Duragesic®, Actiq®, and Fentora®. This Certified Spiking Solution® is suitable for numerous GC/MS or LC/MS testing applications from clinical toxicology and forensic analysis to urine drug testing and pain prescription monitoring.

Legal Information

Actiq is a registered trademark of Anesta Corp.

CERILLIANT is a registered trademark of Cerilliant Corporation

CERTIFIED SPIKING SOLUTION is a registered trademark of Cerilliant Corporation

Duragesic is a registered trademark of Johnson & Johnson

Fentora is a registered trademark of Cima Labs, Inc.

Snap-N-Shoot is a registered trademark of Cerilliant Corporation

Snap-N-Spike is a registered trademark of Cerilliant Corporation

Safety & Documentation

Safety Information

Symbol 
Signal word 
Danger
Target organs 
Eyes
RIDADR 
UN1230 - class 3 - PG 2 - Methanol, solution
WGK Germany 
WGK 2
Flash Point(F) 
49.5 °F - closed cup
Flash Point(C) 
9.7 °C - closed cup

Documents

Certificate of Analysis (COA)

Please Enter a Lot Number
Protocols & Articles

Articles

LC/MS Analysis of Combination Drug Panel in Urine on Ascentis® Express Biphenyl

From our library of Articles, Sigma-Aldrich presents LC/MS Analysis of Combination Drug Panel in Urine on Ascentis® Express Biphenyl
Keywords: High performance liquid chromatography, Liquid chromatography mass spectrometry, Mass spectrometry

LC/MS Analysis of Combination Drug Panel on Ascentis® Express Biphenyl

From our library of Articles, Sigma-Aldrich presents LC/MS Analysis of Combination Drug Panel on Ascentis® Express Biphenyl
Keywords: High performance liquid chromatography, Liquid chromatography mass spectrometry, Mass spectrometry

LC/MS Analysis of Fentanyl and Related Compounds in Urine on Ascentis® Express Biphenyl

From our library of Articles, Sigma-Aldrich presents LC/MS Analysis of Fentanyl and Related Compounds in Urine on Ascentis® Express Biphenyl
Keywords: Chromatography, High performance liquid chromatography, Liquid chromatography mass spectrometry, Mass spectrometry

LC/MS Analysis of Illicit Drugs and Metabolites on Ascentis® Express RP-Amide

From our library of Articles, Sigma-Aldrich presents LC/MS Analysis of Illicit Drugs and Metabolites on Ascentis® Express RP-Amide
Keywords: Chromatography, Forensic, High performance liquid chromatography, Liquid chromatography mass spectrometry, Mass spectrometry, Separation

LC/MS/MS Analysis of Fentanyl and Fentanyl Analogs on Ascentis® Express Biphenyl

From our library of Articles, Sigma-Aldrich presents LC/MS/MS Analysis of Fentanyl and Fentanyl Analogs on Ascentis® Express Biphenyl
Keywords: High performance liquid chromatography, Liquid chromatography mass spectrometry, Mass spectrometry

Peer-Reviewed Papers
15

References

Related Products

related product

Product #

Description

Add to Cart

B-066 Butyryl fentanyl solution, 100 μg/mL in methanol, certified reference material, ampule of 0.5 mL, Cerilliant®
C-162 Carfentanil Oxalate solution, 100 μg/mL in methanol, certified reference material, ampule of 0.5 mL, Cerilliant®
C-163 Carfentanil-D5 Oxalate solution, 100 μg/mL in methanol (as free base), certified reference material, ampule of 0.5 mL, Cerilliant®
M-194 (±)-cis-3-Methylfentanyl hydrochloride solution, 100 μg/mL in methanol (as free base), certified reference material, ampule of 0.5 mL, Cerilliant®
A-139 4-ANPP solution, 100 μg/mL in methanol, certified reference material, ampule of 0.5 mL, Cerilliant®
F-049 p-Fluorofentanyl solution, 100 μg/mL in methanol, certified reference material, ampule of 0.5 mL, Cerilliant®
I-038 Isobutyryl fentanyl hydrochloride solution, 100 μg/mL in methanol (as a free base), certified reference material, ampule of 0.5 mL, Cerilliant®
N-114 Norcarfentanil oxalate oxalate salt solution, 100 μg/mL in methanol (as a free base), certified reference material, ampule of 0.5 mL, Cerilliant®
V-048 Valeryl fentanyl hydrochloride solution, 100 μg/mL in methanol (as a free base), certified reference material, ampule of 0.5 mL, Cerilliant®
A-140 Acryl fentanyl hydrochloride solution, 100 μg/mL in methanol (as free base), certified reference material, ampule of 0.5 mL, Cerilliant®
O-047 Ocfentanil solution, 100 μg/mL in methanol, certified reference material, ampule of 0.5 mL, Cerilliant®
F-048 p-Fluorobutyryl fentanyl (PFBF) solution, 100 μg/mL in methanol (
), certified reference material, ampule of 0.5 mL, Cerilliant®
H-130 (±)-β-Hydroxythiofentanyl hydrochloride solution, 100 μg/mL in methanol (as free base), certified reference material, ampule of 0.5 mL, Cerilliant®
D-168 N-Desmethyl U-47700-D3 solution, 100 μg/mL in acetonitrile, certified reference material, ampule of 1 mL, Cerilliant®
D-167 N-Desmethyl U-47700 solution, 1 mg/mL in acetonitrile, certified reference material, ampule of 1 mL, Cerilliant®
F-050 4-Fluoro-isobutyryl fentanyl solution, 100 μg/mL in methanol, certified reference material, ampule of 0.5 mL, Cerilliant®
A-157 4-ANPP-D5 solution, 100 μg/mL in methanol, certified reference material, ampule of 0.5 mL, Cerilliant®
F-054 o-Fluorofentanyl hydrochloride solution, 100 μg/mL in methanol (as free base), certified reference material, ampule of 0.5 mL, Cerilliant®
M-200 Methoxyacetyl fentanyl hydrochloride solution, 100 μg/mL in methanol (as free base), certified reference material, ampule of 0.5 mL, Cerilliant®
V-068 Valeryl fentanyl-D5 hydrochloride solution, 100 μg/mL in methanol (as free base), certified reference material, ampule of 0.5 mL, Cerilliant®
C-177 Cyclopropyl fentanyl hydrochloride solution, 100 μg/mL in methanol (as free base), certified reference material, ampule of 0.5 mL, Cerilliant®
F-053 Furanyl fentanyl-D5 hydrochloride solution, 100 μg/mL in methanol (as free base), certified reference material, ampule of 0.5 mL, Cerilliant®
W-004 W-18 solution, 1 mg/mL in acetonitrile, certified reference material, ampule of 1 mL, Cerilliant®
A-156 Acryl fentanyl-D5 hydrochloride solution, 100 μg/mL in methanol (as free base), certified reference material, ampule of 0.5 mL, Cerilliant®
P-071 Pain Management Multi-component Opiate Mixture-13 solution, 100 μg/mL each component (10 μg/mL Fentanyl), ampule of 1.0 mL, certified reference material, Cerilliant®
F-001 Fentanyl-D5 solution, 100 μg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
F-002 Fentanyl solution, 100 μg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
F-013 Fentanyl solution, 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
N-030 Norfentanyl-D5 oxalate solution, 100 μg/mL in methanol (as free base), ampule of 1 mL, certified reference material, Cerilliant®
N-055 Norfentanyl-D5 oxalate solution, 1.0 mg/mL in methanol (as free base), ampule of 1 mL, certified reference material, Cerilliant®

Technical Service:

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Bulk Ordering & Pricing:

Need larger quantities for your development, manufacturing or research applications?