• USA Home
  • PHR1207 - Methyl Ethyl Ketone

EMAIL THIS PAGE TO A FRIEND
PHR1207 Supelco

Methyl Ethyl Ketone

Pharmaceutical Secondary Standard; Certified Reference Material

Synonym: 2-Butanone, Ethyl methyl ketone, MEK, Methyl ethyl ketone

Purchase

Properties

Related Categories Additional Standards, Analytical Standards, Analytical/Chromatography, Chromatography, I-Z,
grade   certified reference material
  pharmaceutical secondary standard
vapor density   2.49 (vs air)
vapor pressure   71 mmHg ( 20 °C)
InChI Key   ZWEHNKRNPOVVGH-UHFFFAOYSA-N
form   neat
autoignition temp.   960 °F
expl. lim.   10.1 %
refractive index   n20/D 1.379 (lit.)
bp   80 °C (lit.)
mp   −87 °C (lit.)
density   0.805 g/mL at 25 °C (lit.)
Featured Industry   Pharmaceutical (small molecule)
format   neat
pharmacopeia traceability   traceable to USP 1430101

Description

General description

Pharmaceutical secondary standards for application in quality control, provide pharma laboratories and manufacturers with a convenient and cost-effective alternative to the preparation of in-house working standards.

Application

These Secondary Standards are qualified as Certified Reference Materials. These are suitable for use in several analytical applications including but not limited to pharma release testing, pharma method development for qualitative and quantitative analyses, food and beverage quality control testing, and other calibration requirements.

Analysis Note

These secondary standards offer multi-traceability to the USP, EP and BP primary standards, where they are available.

Other Notes

This Certified Reference Material (CRM) is produced and certified in accordance with ISO 17034 and ISO/IEC 17025. All information regarding the use of this CRM can be found on the certificate of analysis.

Footnote

To see an example of a Certificate of Analysis for this material enter LRAC0146 in the slot below. This is an example certificate only and may not be the lot that you receive.

Safety & Documentation

Safety Information

Symbol 
Signal word 
Danger
Hazard statements 
Supplemental Hazard Statements 
Repeated exposure may cause skin dryness or cracking.
RIDADR 
UN1193 - class 3 - PG 2 - Ethyl methyl ketone
WGK Germany 
1
Flash Point(F) 
26.6 °F
Flash Point(C) 
-3 °C

Documents

Certificate of Analysis (COA)

Please Enter a Lot Number
Protocols & Articles

Articles

GC Analysis of Class 3 Residual Solvents on Equity®-1 after SPME using 100 μm PDMS Fiber

From our library of Articles, Sigma-Aldrich presents GC Analysis of Class 3 Residual Solvents on Equity®-1 after SPME using 100 μm PDMS Fiber
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Pharmaceutical, Size-exclusion chromatography, Solid phase microextractions

GC Analysis of Class 3 Residual Solvents on Equity®-5

From our library of Articles, Sigma-Aldrich presents GC Analysis of Class 3 Residual Solvents on Equity®-5
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Pharmaceutical, Size-exclusion chromatography

GC Analysis of Class 3 Residual Solvents on OVI-G43

From our library of Articles, Sigma-Aldrich presents GC Analysis of Class 3 Residual Solvents on OVI-G43
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Pharmaceutical, Size-exclusion chromatography

GC Analysis of Class 3 Residual Solvents on SUPELCOWAX® 10

From our library of Articles, Sigma-Aldrich presents GC Analysis of Class 3 Residual Solvents on SUPELCOWAX® 10
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Pharmaceutical, Size-exclusion chromatography

GC Analysis of Class 3 Residual Solvents on VOCOL® after SPME using 100 μm PDMS Fiber

From our library of Articles, Sigma-Aldrich presents GC Analysis of Class 3 Residual Solvents on VOCOL® after SPME using 100 μm PDMS Fiber
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Pharmaceutical, Size-exclusion chromatography, Solid phase microextractions

GC Analysis of Industrial Solvents on Equity®-1701

From our library of Articles, Sigma-Aldrich presents GC Analysis of Industrial Solvents on Equity®-1701
Keywords: Chromatography, Flame ionization detector, Gas chromatography

GC Analysis of Industrial Solvents on SUPELCOWAX 10

From our library of Articles, Sigma-Aldrich presents GC Analysis of Industrial Solvents on SUPELCOWAX 10
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification

GC Analysis of Volatiles in Roasted Coffee Beans on Omegawax® after SPME using a 50/30 μm DVB/Carboxen/PDMS Fiber

From our library of Articles, Sigma-Aldrich presents GC Analysis of Volatiles in Roasted Coffee Beans on Omegawax® after SPME using a 50/30 μm DVB/Carboxen/PDMS Fiber
Keywords: Chromatography, Gas chromatography, Mass spectrometry, Purification, Size-exclusion chromatography, Solid phase microextractions

GC Analysis of a 56-Component Industrial Solvents Mix on SLB®-IL60, Comparison to a Polyethylene Glycol (PEG) Column

From our library of Articles, Sigma-Aldrich presents GC Analysis of a 56-Component Industrial Solvents Mix on SLB®-IL60, Comparison to a Polyethylene Glycol (PEG) Column
Keywords: Chromatography, Flame ionization detector, Gas chromatography

US EPA Method 8015: GC Analysis of Nonhalogenated Volatiles on SLB®-5ms

From our library of Articles, Sigma-Aldrich presents US EPA Method 8015: GC Analysis of Nonhalogenated Volatiles on SLB®-5ms
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification

US EPA Method 8260: GC Analysis of Volatiles on SPB®-624 after Purge & Trap using "K" Trap, Fast GC Analysis

From our library of Articles, Sigma-Aldrich presents US EPA Method 8260: GC Analysis of Volatiles on SPB®-624 after Purge & Trap using "K" Trap, Fast GC Analysis
Keywords: Chromatography, Gas chromatography, Gas chromatography mass spectrometry, Mass spectrometry, Purge and trap, Purification, Solid phase microextractions

US EPA Method 8260: GC Analysis of Volatiles on SPB®-624 after Purge & Trap using "K" Trap

From our library of Articles, Sigma-Aldrich presents US EPA Method 8260: GC Analysis of Volatiles on SPB®-624 after Purge & Trap using "K" Trap
Keywords: Chromatography, Environmental, Gas chromatography, Purification, Solid phase microextractions

US EPA Method 8260: GC Analysis of Volatiles on VOCOL® after Purge & Trap using "K" Trap, Fast GC Analysis

From our library of Articles, Sigma-Aldrich presents US EPA Method 8260: GC Analysis of Volatiles on VOCOL® after Purge & Trap using "K" Trap, Fast GC Analysis
Keywords: Chromatography, Gas chromatography, Purification, Solid phase microextractions

US EPA Method 8260: GC Analysis of Volatiles on VOCOL® after Purge & Trap using "K" Trap

From our library of Articles, Sigma-Aldrich presents US EPA Method 8260: GC Analysis of Volatiles on VOCOL® after Purge & Trap using "K" Trap
Keywords: Chromatography, Gas chromatography, Purification, Solid phase microextractions

US EPA Method OLM04.2 VOA: GC Analysis of Volatiles on SPB®-624 after Purge & Trap using "K" Trap, Fast GC Analysis

From our library of Articles, Sigma-Aldrich presents US EPA Method OLM04.2 VOA: GC Analysis of Volatiles on SPB®-624 after Purge & Trap using "K" Trap, Fast GC Analysis
Keywords: Chromatography, Environmental, Gas chromatography, Purification, Solid phase microextractions

US EPA Method OLM04.2 VOA: GC Analysis of Volatiles on VOCOL® after Purge & Trap using "K" Trap, Fast GC Analysis

From our library of Articles, Sigma-Aldrich presents US EPA Method OLM04.2 VOA: GC Analysis of Volatiles on VOCOL® after Purge & Trap using "K" Trap, Fast GC Analysis
Keywords: Chromatography, Environmental, Gas chromatography, Purification, Solid phase microextractions

US EPA Method TO-17: GC Analysis of Volatiles on Equity®-1 after Collection/Desorption using Carbotrap 300 Tube

From our library of Articles, Sigma-Aldrich presents US EPA Method TO-17: GC Analysis of Volatiles on Equity®-1 after Collection/Desorption using Carbotrap 300 Tube
Keywords: Chromatography, Gas chromatography

Peer-Reviewed Papers
15

References

Related Products

Technical Service:

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Bulk Ordering & Pricing:

Need larger quantities for your development, manufacturing or research applications?