EMAIL THIS PAGE TO A FRIEND
PHR1219 Supelco

Acetone

Pharmaceutical Secondary Standard; Certified Reference Material

  • Linear Formula CH3COCH3

  • Molecular Weight 58.08

  •  Beilstein/REAXYS Number 635680

  •  EC Number 200-662-2

  •  MDL number MFCD00008765

  •  PubChem Substance ID 329823226

  •  NACRES NA.24

Purchase

Properties

Related Categories A-B, Analytical Standards, Analytical/Chromatography, Chinese Food Contact Materials Regulation GB 9685 2016, Food & Beverage Standards,
Quality Level   300
grade   certified reference material
  pharmaceutical secondary standard
vapor density   2 (vs air)
vapor pressure   184 mmHg ( 20 °C)
form   neat
expl. lim.   13.2 %
application(s)   HPLC: suitable
  gas chromatography (GC): suitable
refractive index   n20/D 1.359 (lit.)
bp   56 °C/760 mmHg (lit.)
mp   −94 °C (lit.)
density   0.791 g/mL at 25 °C (lit.)
Featured Industry   Pharmaceutical (small molecule)
format   neat
pharmacopeia traceability   traceable to USP 1006801
SMILES string   CC(C)=O
InChI   1S/C3H6O/c1-3(2)4/h1-2H3
InChI key   CSCPPACGZOOCGX-UHFFFAOYSA-N

Description

General description

Pharmaceutical secondary standards for application in quality control provide pharma laboratories and manufacturers with a convenient and cost-effective alternative to the preparation of in-house working standards. Acetone is an organic compound and in contrast to petroleum based hexane, it is a biorenewable solvent obtained via fermentation. It is generally used as a solvent for many gums, resins, and in the production of plastics.

Application

Acetone′s luminesence intensity is dependent upon the solution components . The absorption of UV light by acetone, results in its photolysis and the production of radials .

These Secondary Standards are qualified as Certified Reference Materials. These are suitable for use in several analytical applications including but not limited to pharma release testing, pharma method development for qualitative and quantitative analyses, food and beverage quality control testing, and other calibration requirements.

Analysis Note

These secondary standards offer multi-traceability to the USP, EP (PhEur) and BP primary standards, where they are available.

Other Notes

This Certified Reference Material (CRM) is produced and certified in accordance with ISO 17034 and ISO/IEC 17025. All information regarding the use of this CRM can be found on the certificate of analysis.

Footnote

To see an example of a Certificate of Analysis for this material enter LRAB5525 in the slot below. This is an example certificate only and may not be the lot that you receive.

Safety & Documentation

Safety Information

Symbol 
Signal word 
Danger
Hazard statements 
Target organs 
Central nervous system
Supplemental Hazard Statements 
EUH066
RIDADR 
UN1090 - class 3 - PG 2 - Acetone
WGK Germany 
WGK 1
RTECS 
AL3150000
Flash Point(F) 
1.4 °F - closed cup
Flash Point(C) 
-17.0 °C - closed cup
Protocols & Articles

Articles

EPA Method TO-11/IP-6A and ASTM® D5197: HPLC Analysis of Aldehydes and Ketones on SUPELCOSIL™ LC-18 after Collection/Desorption using LpDNPH

From our library of Articles, Sigma-Aldrich presents EPA Method TO-11/IP-6A and ASTM® D5197: HPLC Analysis of Aldehydes and Ketones on SUPELCOSIL™ LC-18 after Collection/Desorption using LpDNPH
Keywords: Air Monitoring, Chromatography, High performance liquid chromatography, Sample preparations, Solid phase extractions

GC Analysis of Blood Alcohols in Human Plasma on SUPELCOWAX® 10 after SPME using 60 μm Carbowax® Fiber

From our library of Articles, Sigma-Aldrich presents GC Analysis of Blood Alcohols in Human Plasma on SUPELCOWAX® 10 after SPME using 60 μm Carbowax® Fiber
Keywords: Chromatography, Clinical, Flame ionization detector, Forensic, Gas chromatography, Pharmaceutical, Purification, Solid phase microextractions

GC Analysis of Blood Alcohols on SUPELCOWAX® 10

From our library of Articles, Sigma-Aldrich presents GC Analysis of Blood Alcohols on SUPELCOWAX® 10
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification

GC Analysis of Blood Alcohols on a Packed Column (5% Carbowax® 20M on 60/80 °Carbopack™ B)

From our library of Articles, Sigma-Aldrich presents GC Analysis of Blood Alcohols on a Packed Column (5% Carbowax® 20M on 60/80 °Carbopack™ B)
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification

GC Analysis of Class 3 Residual Solvents on Equity®-1 after SPME using 100 μm PDMS Fiber

From our library of Articles, Sigma-Aldrich presents GC Analysis of Class 3 Residual Solvents on Equity®-1 after SPME using 100 μm PDMS Fiber
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Pharmaceutical, Size-exclusion chromatography, Solid phase microextractions

GC Analysis of Class 3 Residual Solvents on Equity®-5

From our library of Articles, Sigma-Aldrich presents GC Analysis of Class 3 Residual Solvents on Equity®-5
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Pharmaceutical, Size-exclusion chromatography

GC Analysis of Class 3 Residual Solvents on OVI-G43

From our library of Articles, Sigma-Aldrich presents GC Analysis of Class 3 Residual Solvents on OVI-G43
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Pharmaceutical, Size-exclusion chromatography

GC Analysis of Class 3 Residual Solvents on SUPELCOWAX® 10

From our library of Articles, Sigma-Aldrich presents GC Analysis of Class 3 Residual Solvents on SUPELCOWAX® 10
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Pharmaceutical, Size-exclusion chromatography

GC Analysis of Class 3 Residual Solvents on VOCOL® after SPME using 100 μm PDMS Fiber

From our library of Articles, Sigma-Aldrich presents GC Analysis of Class 3 Residual Solvents on VOCOL® after SPME using 100 μm PDMS Fiber
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Pharmaceutical, Size-exclusion chromatography, Solid phase microextractions

GC Analysis of Fermentation Compounds on a Packed Column (6.6% Carbowax® 20M on 80/120 °Carbopack™ B AW)

From our library of Articles, Sigma-Aldrich presents GC Analysis of Fermentation Compounds on a Packed Column (6.6% Carbowax® 20M on 80/120 °Carbopack™ B AW)
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification

GC Analysis of Industrial Solvents on Equity®-1701

From our library of Articles, Sigma-Aldrich presents GC Analysis of Industrial Solvents on Equity®-1701
Keywords: Chromatography, Flame ionization detector, Gas chromatography

GC Analysis of Industrial Solvents on Equity®-1

From our library of Articles, Sigma-Aldrich presents GC Analysis of Industrial Solvents on Equity®-1
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification, Size-exclusion chromatography

GC Analysis of Industrial Solvents on SUPELCOWAX 10

From our library of Articles, Sigma-Aldrich presents GC Analysis of Industrial Solvents on SUPELCOWAX 10
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification

GC Analysis of Residual Solvents on SPB®-624 after SPME using 100 μm PDMS Fiber

From our library of Articles, Sigma-Aldrich presents GC Analysis of Residual Solvents on SPB®-624 after SPME using 100 μm PDMS Fiber
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Pharmaceutical, Purification, Sample preparations, Solid phase microextractions

GC Analysis of Solvents on a Packed Column (3% SP-1500 on Carbopack™ B)

From our library of Articles, Sigma-Aldrich presents GC Analysis of Solvents on a Packed Column (3% SP-1500 on Carbopack™ B)
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification

GC Analysis of Volatiles in Drywall on SPB®-HAP after Collection/Desorption using Carbotrap® 300 Tube

From our library of Articles, Sigma-Aldrich presents GC Analysis of Volatiles in Drywall on SPB®-HAP after Collection/Desorption using Carbotrap® 300 Tube
Keywords: Air Monitoring, Chromatography, Gas chromatography, Purification

GC Analysis of Volatiles in Milk (Before and After Exposure to Sunlight) on Supel-Q™ PLOT after SPME using a 75 μm PDMS/Carboxen Fiber

From our library of Articles, Sigma-Aldrich presents GC Analysis of Volatiles in Milk (Before and After Exposure to Sunlight) on Supel-Q™ PLOT after SPME using a 75 μm PDMS/Carboxen Fiber
Keywords: Chromatography, Gas chromatography, Gas chromatography mass spectrometry, Mass spectrometry, Purification, Sample preparations, Separation, Solid phase microextractions

GC Analysis of Volatiles in PVC Pipe on SPB®-HAP after Collection/Desorption using Carbotrap® 300 Tube

From our library of Articles, Sigma-Aldrich presents GC Analysis of Volatiles in PVC Pipe on SPB®-HAP after Collection/Desorption using Carbotrap® 300 Tube
Keywords: Air Monitoring, Chromatography, Gas chromatography, Purification

GC Analysis of Volatiles in Water on Equity®-1 after SPME using 30 μm PDMS Fiber

From our library of Articles, Sigma-Aldrich presents GC Analysis of Volatiles in Water on Equity®-1 after SPME using 30 μm PDMS Fiber
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification, Size-exclusion chromatography, Solid phase microextractions

GC Analysis of a 56-Component Industrial Solvents Mix on SLB®-IL60, Comparison to a Polyethylene Glycol (PEG) Column

From our library of Articles, Sigma-Aldrich presents GC Analysis of a 56-Component Industrial Solvents Mix on SLB®-IL60, Comparison to a Polyethylene Glycol (PEG) Column
Keywords: Chromatography, Flame ionization detector, Gas chromatography

GC Analysis of an Indoor Air Standard on Equity®-1

From our library of Articles, Sigma-Aldrich presents GC Analysis of an Indoor Air Standard on Equity®-1
Keywords: Air Monitoring, Chromatography, Gas chromatography, Purification, Size-exclusion chromatography

HPLC Analysis of Urea, Carbamate, Triazine, Aniline Pesticides on Discovery® C18

From our library of Articles, Sigma-Aldrich presents HPLC Analysis of Urea, Carbamate, Triazine, Aniline Pesticides on Discovery® C18
Keywords: Chromatography, Environmental, Environmental Analysis, Herbicides, High performance liquid chromatography, Pesticides

US EPA Method 8260: GC Analysis of Volatiles on SPB®-624 after Purge & Trap using "K" Trap, Fast GC Analysis

From our library of Articles, Sigma-Aldrich presents US EPA Method 8260: GC Analysis of Volatiles on SPB®-624 after Purge & Trap using "K" Trap, Fast GC Analysis
Keywords: Chromatography, Gas chromatography, Gas chromatography mass spectrometry, Mass spectrometry, Purge and trap, Purification, Solid phase microextractions

US EPA Method 8260: GC Analysis of Volatiles on SPB®-624 after Purge & Trap using "K" Trap

From our library of Articles, Sigma-Aldrich presents US EPA Method 8260: GC Analysis of Volatiles on SPB®-624 after Purge & Trap using "K" Trap
Keywords: Chromatography, Environmental, Gas chromatography, Purification, Solid phase microextractions

US EPA Method 8260: GC Analysis of Volatiles on VOCOL® after Purge & Trap using "K" Trap, Fast GC Analysis

From our library of Articles, Sigma-Aldrich presents US EPA Method 8260: GC Analysis of Volatiles on VOCOL® after Purge & Trap using "K" Trap, Fast GC Analysis
Keywords: Chromatography, Gas chromatography, Purification, Solid phase microextractions

US EPA Method 8260: GC Analysis of Volatiles on VOCOL® after Purge & Trap using "K" Trap

From our library of Articles, Sigma-Aldrich presents US EPA Method 8260: GC Analysis of Volatiles on VOCOL® after Purge & Trap using "K" Trap
Keywords: Chromatography, Gas chromatography, Purification, Solid phase microextractions

US EPA Method OLM04.2 VOA: GC Analysis of Volatiles on SPB®-624 after Purge & Trap using "K" Trap, Fast GC Analysis

From our library of Articles, Sigma-Aldrich presents US EPA Method OLM04.2 VOA: GC Analysis of Volatiles on SPB®-624 after Purge & Trap using "K" Trap, Fast GC Analysis
Keywords: Chromatography, Environmental, Gas chromatography, Purification, Solid phase microextractions

US EPA Method OLM04.2 VOA: GC Analysis of Volatiles on VOCOL® after Purge & Trap using "K" Trap, Fast GC Analysis

From our library of Articles, Sigma-Aldrich presents US EPA Method OLM04.2 VOA: GC Analysis of Volatiles on VOCOL® after Purge & Trap using "K" Trap, Fast GC Analysis
Keywords: Chromatography, Environmental, Gas chromatography, Purification, Solid phase microextractions

US EPA Method TO-17: GC Analysis of Volatiles on Equity®-1 after Collection/Desorption using Carbotrap 300 Tube

From our library of Articles, Sigma-Aldrich presents US EPA Method TO-17: GC Analysis of Volatiles on Equity®-1 after Collection/Desorption using Carbotrap 300 Tube
Keywords: Chromatography, Gas chromatography

Peer-Reviewed Papers
15

References

Related Products

Technical Service:

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Bulk Ordering & Pricing:

Need larger quantities for your development, manufacturing or research applications?