Articles
DRO, EPH, ETPH, GRO, PRO, PVOC, STARS, TPH, VPH? Help, I’m Trapped in Alphabet Soup!
The analysis of samples resulting from fuel and oil spills is different from the analyses routinely performed by either a petroleum or an environmental testing laboratory.
Katherine K. Stenerson andMichael D. Buchanan
Reporter US Volume 28.4
Keywords: Chromatography, Degradations, Environmental, Evaporation, Gas chromatography, Help, Methods, Phase transitions, Purge and trap, Sample preparations, Type
Determination of Headspace Volatiles in Distilled Spirits Using SPME Coupled to GC
A beverage manufacturer may be interested in the overall composition of their product, or may need to determine the levels of alcohol, caffeine, nutraceuticals, antioxidants, vitamins, sweeteners, ar...
Robert E. Shirey, Michael D. Buchanan, and Daniel Vitkuske
Reporter US Volume 34.1
Keywords: Chromatography, Gas chromatography, Industries, Sample preparations, Solid phase extractions, Solid phase microextractions, Vitamins
Fast GC Analyses of Volatiles
The primary aim of Fast GC is to maintain (compared to conventional GC) sufficient resolving power in a shorter time. Basically, Fast GC is accomplished by using a short column (reduces analysis time...
Michael D. Buchanan
Reporter US Volume 26.1
Keywords: Chromatography, Gas chromatography, Mass spectrometry, Purge and trap
GC Analysis of Volatiles in Bourbon Liqueur on VOCOL® after SPME using 50/30 μm DVB/Carboxen®/PDMS Fiber
From our library of Articles, Sigma-Aldrich presents GC Analysis of Volatiles in Bourbon Liqueur on VOCOL® after SPME using 50/30 μm DVB/Carboxen®/PDMS Fiber
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Sample preparations, Solid phase extractions, Solid phase microextractions
GC Analysis of Volatiles in Canadian Whiskey on VOCOL® after SPME using 50/30 μm DVB/Carboxen®/PDMS Fiber
From our library of Articles, Sigma-Aldrich presents GC Analysis of Volatiles in Canadian Whiskey on VOCOL® after SPME using 50/30 μm DVB/Carboxen®/PDMS Fiber
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Sample preparations, Solid phase extractions, Solid phase microextractions
GC Analysis of Volatiles in Gin on VOCOL® after SPME using 50/30 μm DVB/Carboxen®/PDMS Fiber
From our library of Articles, Sigma-Aldrich presents GC Analysis of Volatiles in Gin on VOCOL® after SPME using 50/30 μm DVB/Carboxen®/PDMS Fiber
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Sample preparations, Solid phase extractions, Solid phase microextractions
GC Analysis of Volatiles in Irish Whiskey on VOCOL® after SPME using 50/30 μm DVB/Carboxen®/PDMS Fiber
From our library of Articles, Sigma-Aldrich presents GC Analysis of Volatiles in Irish Whiskey on VOCOL® after SPME using 50/30 μm DVB/Carboxen®/PDMS Fiber
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Sample preparations, Solid phase extractions, Solid phase microextractions
GC Analysis of Volatiles in Kentucky Bourbon (Sample 1) on VOCOL® after SPME using 50/30 μm DVB/Carboxen®/PDMS Fiber, 15%(w/v) Salt Added
From our library of Articles, Sigma-Aldrich presents GC Analysis of Volatiles in Kentucky Bourbon (Sample 1) on VOCOL® after SPME using 50/30 μm DVB/Carboxen®/PDMS Fiber, 15%(w/v) Salt Added
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Sample preparations, Solid phase extractions, Solid phase microextractions
GC Analysis of Volatiles in Kentucky Bourbon (Sample 1) on VOCOL® after SPME using 50/30 μm DVB/Carboxen®/PDMS Fiber
From our library of Articles, Sigma-Aldrich presents GC Analysis of Volatiles in Kentucky Bourbon (Sample 1) on VOCOL® after SPME using 50/30 μm DVB/Carboxen®/PDMS Fiber
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Sample preparations, Solid phase extractions, Solid phase microextractions
GC Analysis of Volatiles in Kentucky Bourbon (Sample 2) on VOCOL® after SPME using 50/30 μm DVB/Carboxen®/PDMS Fiber
From our library of Articles, Sigma-Aldrich presents GC Analysis of Volatiles in Kentucky Bourbon (Sample 2) on VOCOL® after SPME using 50/30 μm DVB/Carboxen®/PDMS Fiber
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Sample preparations, Solid phase extractions, Solid phase microextractions
GC Analysis of Volatiles in Scotch (18 Year Old) on VOCOL® after SPME using 50/30 μm DVB/Carboxen®/PDMS Fiber
From our library of Articles, Sigma-Aldrich presents GC Analysis of Volatiles in Scotch (18 Year Old) on VOCOL® after SPME using 50/30 μm DVB/Carboxen®/PDMS Fiber
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Sample preparations, Solid phase extractions, Solid phase microextractions
GC Analysis of Volatiles in Scotch (8 Year Old) on VOCOL® after SPME using 50/30 μm DVB/Carboxen®/PDMS Fiber
From our library of Articles, Sigma-Aldrich presents GC Analysis of Volatiles in Scotch (8 Year Old) on VOCOL® after SPME using 50/30 μm DVB/Carboxen®/PDMS Fiber
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Sample preparations, Solid phase extractions, Solid phase microextractions
GC Analysis of Volatiles in Tennessee Whiskey on VOCOL® after SPME using 50/30 μm DVB/Carboxen®/PDMS Fiber
From our library of Articles, Sigma-Aldrich presents GC Analysis of Volatiles in Tennessee Whiskey on VOCOL® after SPME using 50/30 μm DVB/Carboxen®/PDMS Fiber
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Sample preparations, Solid phase extractions, Solid phase microextractions
GC Analysis of Volatiles in White Wine on VOCOL® after SPME using a 75 μm Carboxen/PDMS Fiber
From our library of Articles, Sigma-Aldrich presents GC Analysis of Volatiles in White Wine on VOCOL® after SPME using a 75 μm Carboxen/PDMS Fiber
Keywords: Chromatography, Gas chromatography, Gas chromatography mass spectrometry, Mass spectrometry, Purification, Solid phase microextractions
GC Analysis of Volatiles on VOCOL® after SPME using 75 μm Carboxen/PDMS Fiber
From our library of Articles, Sigma-Aldrich presents GC Analysis of Volatiles on VOCOL® after SPME using 75 μm Carboxen/PDMS Fiber
Keywords: Chromatography, Gas chromatography, Mass spectrometry, Purification, Size-exclusion chromatography, Solid phase microextractions
GC Column Selection Guide
The History of Supelco and the Capillary Column How to Choose a Capillary Column Additional Reading/Product Literature Column Phase Selection by Industry Column Phase Selection by Application Cross-R...
Keywords: Adsorption, Air Monitoring, Chemical industry, Chromatography, Derivatizations, Detection methods, Electron capture detector, Environmental, Gas chromatography, Herbicides, High performance liquid chromatography, Immobilization, Industries, Mass selective detector, Mass spectrometry, Metabolites, Nitrogen phosphorus detector, Pesticides, Pharmaceutical, Purification, Separation, Size-exclusion chromatography, Solid phase extractions, Solid phase microextractions, Solvents, Substitutions
The Effect of Container Materials on Production of Light Induced Milk – A Study Using SPME-GC-MS
Light induced off-flavors (LIOFs) in milk became an issue when dairies began to package milk in high density polyethylene (HDPE) plastic jugs instead of glass bottles. There are several types of LIOF...
Keywords: Degradations, Free radical reactions, Gas chromatography, Mass selective detector, Mass spectrometry, Oxidations, Sample preparations, Solid phase microextractions
US EPA Method 8015 (modified): GC Analysis of Gasoline Range Organics (GRO) on VOCOL® after Purge & Trap using "M" Trap
From our library of Articles, Sigma-Aldrich presents US EPA Method 8015 (modified): GC Analysis of Gasoline Range Organics (GRO) on VOCOL® after Purge & Trap using "M" Trap
Keywords: Chromatography, Environmental, Flame ionization detector, Gas chromatography, Purification, Solid phase microextractions
US EPA Method 8260: GC Analysis of Volatiles on VOCOL® after Purge & Trap using "K" Trap
From our library of Articles, Sigma-Aldrich presents US EPA Method 8260: GC Analysis of Volatiles on VOCOL® after Purge & Trap using "K" Trap
Keywords: Chromatography, Gas chromatography, Purification, Solid phase microextractions
How to Choose a Capillary GC Column
An optimized chromatographic separation begins with the column. The selection of the proper capillary column for any application should be based on four significant factors:
How to Choose a Capillary GC Column
Keywords: Chromatography, Condensations, Gas chromatography, Immobilization, Mass spectrometry, Pesticides, Separation, Size-exclusion chromatography, Solid phase microextractions, Solvents, Vaporization