• USA Home
  • 29647-U - SLB®-IL111 Capillary GC Column

EMAIL THIS PAGE TO A FRIEND
29647-U Supelco

SLB®-IL111 Capillary GC Column

L × I.D. 100 m × 0.25 mm, df 0.20 μm

  •  eCl@ss 32119290

  •  NACRES SB.54

Purchase

Properties

Related Categories All Gas Chromatography Columns, Analytical/Chromatography, Capillary GC Columns, Capillary GC Columns, by name, Gas Chromatography (GC),
Quality Level   100
material   fused silica
parameter   50-270 °C temperature (isothermal or programmed)
Beta value   313
df   0.20 μm
application(s)   gas chromatography (GC): suitable
L × I.D.   100 m × 0.25 mm
matrix active group   Non-bonded; 1,5-Di(2,3-dimethylimidazolium)pentane bis(trifluoromethanesulfonyl)imide phase
Featured Industry   Agriculture
Biofuels
Chemicals and Industrial Polymers
Clinical
Environmental
Food and Beverages
Petroleum
column type   capillary extremely polar

Description

General description

Application: World’s first commercial column to rate over 100 on our GC column polarity scale. Selectivity most orthogonal to non-polar and intermediate polar phases, resulting in very unique elution patterns. Maximum temperature of 270 ºC is very impressive for such an extremely polar column. Great choice for separation of polarizable analytes (contain double and/or triple C-C bonds) from neutral analytes. Also a good GCxGC column choice. Launched in 2010.
USP Code: None
Phase:
• Non-bonded
• 1,5-Di(2,3-dimethylimidazolium)pentane bis(trifluoromethylsulfonyl)imide
Temp. Limits:
• 50 °C to 270 °C (isothermal or programmed)

Other Notes

Complementary products:
Syringes
Vials
Gas Purification and Gas Management
Inlet Liners, Glass Wool, and Specialized Hand Tools
Septa and Specialized Hand Tools
Column Ferrules, Nuts, and Specialized Hand Tools

Legal Information

SLB is a registered trademark of Sigma-Aldrich Co. LLC

Safety & Documentation

Safety Information

WGK Germany 
WGK 3
Flash Point(F) 
Not applicable
Flash Point(C) 
Not applicable

Documents

Certificate of Analysis (COA)

Please Enter a Lot Number

Frequently Asked Questions

Which document(s) contains shelf-life or expiration date information for a given product?
If available for a given product, the recommended re-test date or the expiration date can be found on the Certificate of Analysis.
How do I get lot-specific information or a Certificate of Analysis?
The lot specific COA document can be found by entering the lot number above under the "Documents" section.
How do I find price and availability?
There are several ways to find pricing and availability for our products. Once you log onto our website, you will find the price and availability displayed on the product detail page. You can contact any of our Customer Sales and Service offices to receive a quote. USA customers: 1-800-325-3010 or view local office numbers.
What is the Department of Transportation shipping information for this product?
Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.
Are all the SLB Ionic Liquid Capillary Columns GC-MS compatible?
SLB-IL59, SLB-IL60, SLB-IL61, SLB-IL76, SLB-IL82, SLB-IL100 and SLB-IL111Ionic Liquid Capillary Columns are allGC-MS compatible.
My question is not addressed here, how can I contact Technical Service for assistance?
Ask a Scientist here.
My question is not addressed here, how can I contact Technical Service for assistance?
Ask a Scientist here.
Show more questions
Protocols & Articles

Articles

GC Analysis of C18:1 FAMEs in Partially Hydrogenated Vegetable Oil (PHVO) on SLB®-IL111

From our library of Articles, Sigma-Aldrich presents GC Analysis of C18:1 FAMEs in Partially Hydrogenated Vegetable Oil (PHVO) on SLB®-IL111
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification

GC Analysis of FAMEs in Cookies on SLB®-IL111 after SPE Fractionation using Discovery® Ag-Ion

From our library of Articles, Sigma-Aldrich presents GC Analysis of FAMEs in Cookies on SLB®-IL111 after SPE Fractionation using Discovery® Ag-Ion
Keywords: Capillary electrophoresis, Chromatography, Digestions, Flame ionization detector, Gas chromatography, Hydrogenations, Methylations, Purification, Sample preparations, Solid phase extractions

GC Analysis of FAMEs in Cow's Milk on SLB®-IL111

From our library of Articles, Sigma-Aldrich presents GC Analysis of FAMEs in Cow's Milk on SLB®-IL111
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification

GC Analysis of FAMEs in Goat Milk on SLB®-IL111

From our library of Articles, Sigma-Aldrich presents GC Analysis of FAMEs in Goat Milk on SLB®-IL111
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification

GC Analysis of FAMEs in Human Milk on SLB®-IL111

From our library of Articles, Sigma-Aldrich presents GC Analysis of FAMEs in Human Milk on SLB®-IL111
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification

GC Analysis of FAMEs in Human Plasma on SLB®-IL111

From our library of Articles, Sigma-Aldrich presents GC Analysis of FAMEs in Human Plasma on SLB®-IL111
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification

GC Analysis of FAMEs in Mozzarella (Buffalo Milk Source) on SLB®-IL111

From our library of Articles, Sigma-Aldrich presents GC Analysis of FAMEs in Mozzarella (Buffalo Milk Source) on SLB®-IL111
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification

GC Analysis of FAMEs in Walnuts on SLB®-IL111

From our library of Articles, Sigma-Aldrich presents GC Analysis of FAMEs in Walnuts on SLB®-IL111
Keywords: Capillary electrophoresis, Chromatography, Digestions, Flame ionization detector, Gas chromatography, Methylations, Purification

GC Analysis of Fatty Acids in Walnuts and Peanuts

Nuts are considered nutrient dense foods and their consumption has been associated with reduced risk of coronary heart disease. The health benefits of nuts are partially attributable to their high co...
Katherine K. Stenerson
Reporter US Volume 31.3
Keywords: Capillary electrophoresis, Digestions, Flame ionization detector, Gas chromatography, Methylations

GC Analysis of a 37-Component FAME Mix on SLB®-IL111

From our library of Articles, Sigma-Aldrich presents GC Analysis of a 37-Component FAME Mix on SLB®-IL111
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification

GC Analysis of cis C18:1 FAMEs in Partially Hydrogenated Vegetable Oil (PHVO) on SLB®-IL111 after HPLC Fractionation using Silver Ion

From our library of Articles, Sigma-Aldrich presents GC Analysis of cis C18:1 FAMEs in Partially Hydrogenated Vegetable Oil (PHVO) on SLB®-IL111 after HPLC Fractionation using Silver Ion
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification

GC Analysis of trans C18:1 FAMEs in Partially Hydrogenated Vegetable Oil (PHVO) on SLB®-IL111 after HPLC Fractionation using Silver Ion

From our library of Articles, Sigma-Aldrich presents GC Analysis of trans C18:1 FAMEs in Partially Hydrogenated Vegetable Oil (PHVO) on SLB®-IL111 after HPLC Fractionation using Silver Ion
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification

Ionic Liquid GC Capillary Columns

That’s why we offer the only portfolio of Ionic Liquid GC columns under the Supelco brand, providing you the accuracy, precision and consistency you need.
Keywords: Chromatography, Gas chromatography, PAGE

Trans Fats in Cookies using SP-2560 and SLB-IL111

Trans fats (trans unsaturated fatty acids) are fatty acids that contain at least one double bond in the trans orientation. This orientation causes carbon atoms to align in a straight configuration, s...
Katherine K. Stenerson
Reporter US Volume 30.2
Keywords: Capillary electrophoresis, Chromatography, Derivatizations, Digestions, Flame ionization detector, Fractionation, Gas chromatography, Hydrogenations, Methylations, Solid phase extractions

Related Content

How to Choose a Capillary GC Column

An optimized chromatographic separation begins with the column. The selection of the proper capillary column for any application should be based on four significant factors:
How to Choose a Capillary GC Column
Keywords: Chromatography, Condensations, Gas chromatography, Immobilization, Mass spectrometry, Pesticides, Separation, Size-exclusion chromatography, Solid phase microextractions, Solvents, Vaporization

Related Products

Technical Service:

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Bulk Ordering & Pricing:

Need larger quantities for your development, manufacturing or research applications?