• USA Home
  • 53834-U - Ascentis® Express C8, 2.7 Micron HPLC Column

EMAIL THIS PAGE TO A FRIEND
53834-U Supelco

Ascentis® Express C8, 2.7 Micron HPLC Column

2.7 μm particle size, L × I.D. 15 cm × 2.1 mm

  •  eCl@ss 32110501

Purchase

Properties

Related Categories Analytical/Chromatography, Ascentis Express C8 Columns, Ascentis Express C8, 2.7μm HPLC Columns, Ascentis Express Columns for Fast HPLC, C8, 2.7μm Columns,
feature   endcapped
parameter   60 °C temp. range
  600 bar max. pressure (9000 psi)
application(s)   HPLC: suitable
L × I.D.   15 cm × 2.1 mm
impurities   <5 ppm metals
matrix   Fused-Core particle platform
matrix active group   C8 (octyl) phase
particle size   2.7 μm
pore size   90 Å
operating pH range   2 - 9
suitability   suitable for L7 per USP
separation technique   reversed phase

Description

General description

Ascentis Express HPLC columns, through the use of Fused-Core® particle technology, can provide you with both the high speed and high efficiencies of sub-2 μm particles while maintaining lower backpressures. The combination of high efficiency and low backpressure benefits UPLC® (or other ultra high pressure system) users, as well as conventional HPLC users.
Visit the Ascentis Express home page for more information on this new column technology.

Legal Information

Ascentis is a registered trademark of Sigma-Aldrich Co. LLC

Fused-Core is a registered trademark of Advanced Materials Technology, Inc.

UPLC is a registered trademark of Waters

Safety & Documentation

Safety Information

RIDADR 
NONH for all modes of transport
WGK Germany 
3

Documents

Certificate of Analysis

Frequently Asked Questions

Which document(s) contains shelf-life or expiration date information for a given product?
If available for a given product, the recommended re-test date or the expiration date can be found on the Certificate of Analysis.
How do I get lot-specific information or a Certificate of Analysis?
The lot specific COA document can be found by entering the lot number above under the "Documents" section.
What is special about Ascentis Express?
Ascentis Express columns provide a breakthrough in HPLC performance. Based on Fused-Core particle technology, Ascentis Express provides the benefits of sub-2 μm particles but at much lower backpressure.These benefits include the capability of providing fast HPLC and higher resolution chromatography.The Fused-Core particle consists of a 1.7 μm solid core and a 0.5 μm porous shell.A major benefit of the Fused-Core particle is the small diffusion path (0.5 μm) compared to conventional fully porous particles. The shorter diffusion path reduces axial dispersion of solutes and minimizes peak broadening.
When are additional phases expected?
Additional phases are being developed.The best way to track new products is to visitAscentis Express for the latest updates.
Is there anything special I need to do to my HPLC system to use Ascentis Express?
Nothing special is required to use Ascentis Express HPLC columns.To obtain the full benefits of Ascentis Express, one should minimize dispersion in the HPLC system (tubing, detector flow cell) as well as confirm the detector response system is set at a fast level.For more information, request Guidelines for Optimizing Systems for Ascentis Express Columns (T407102).
Can I use Ascentis Express on any type of HPLC system?
Ascentis Express HPLC columns are capable of use on standard HPLC systems as well as UHPLC systems.Columns are packed in high pressure hardware capable of withstanding the pressures used in UHPLC systems.
Can I use Ascentis Express on a UHPLC system?
Yes.Ascentis Express columns are packed in a way making them suitable for these ultra high pressure instruments.In fact, Ascentis Express outperforms sub-2 μm micron columns on many applications since Ascentis Express provides the benefits of sub-2 μm particles but at much lower back pressure.These benefits include the capability of providing fast HPLC and higher resolution chromatography.The Fused-Core particle consists of a 1.7 μm solid core and a 0.5 μm porous shell.A major benefit of the Fused-Core particle is the small diffusion path (0.5 μm) compared to conventional fully porous particles. The shorter diffusion path reduces axial dispersion of solutes and minimizes peak broadening.
How do I find price and availability?
There are several ways to find pricing and availability for our products.Once you log onto our website, you will find the price and availability displayed on the product detail page.You can contact any of our Customer Sales and Service offices to receive a quote. USA customers: 1-800-325-3010 orview local office numbers.
What is the Department of Transportation shipping information for this product?
Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.
How can I measure my instrument bandwidth (IBW) and determine whatAscentis® Express HPLC Columns can be used with minimal efficiency loss created by too much internal instrument volume?
The Guide to Dispersion Measurement has simple instructions on how to measure IBW and can be found at sigma-aldrich.com/express.
Do I need special fittings and tubing to connect Ascentis® Express HPLC Columns?
While operating pressures may not exceed the 400 bar (6,000 psi) capability of your traditional instruments, sustained pressures of about 200 bar (3,000 psi) will exceed the recommended pressure for conventional PEEK tubing and fittings at the column inlet. We recommend changing to stainless steel fittings in all high pressure locations and have designed special High Performance HPLC Fittings/Interconnects that will stay tight at pressures of 1,000 bar (15,000 psi) or greater, even when elevated column temperatures are employed.
What flow rate should I use with Ascentis® ExpressHPLC Columns?
Based on the minimum in the van Deemter curves, higher flows than 5um particle columns are required in order to maximize Ascentis Express column efficiency. The suggested starting point for flow rate for Ascentis Express columns: 1.6 mL/min for 4.6 mm ID;0.8 mL/min for 3.0 mm ID; and 0.4mL/min for 2.1 mm ID.
Can Ascentis® Express HPLC Columns be used for LC-MS?
Express Fused-Core particles were designed with LC-MS in mind. Even extremely short column lengths exhibit sufficient plate counts to show high resolving power. The flat van Deemter plots permit resolution to be maintained at very high flow rates to maximize sample throughput. All Ascentis stationary phases have been evaluated for MS compatibility during their development, and the Express phases are no exception. You can expect extremely low column bleed and background while maintaining longest possible column lifetime. A bonus of Ascentis Express columns for high throughput UHPLC and LC-MS is that they are extremely rugged and highly resistant to plugging, a very common failure mode for competitor columns.
My question is not addressed here, how can I contact Technical Service for assistance?
Ask a Scientist here.
Show more questions

PTFE Millex filter

Milli-Q® Water Purification Solutions
Protocols & Articles

Articles

Ascentis Express UHPLC Columns with 2.0 μm Fused-Core Particles

The new Supelco Ascentis® Express column line has been designed specifically for UHPLC instruments with 2.0 µm Fused-Core® silica, as diagrammed in Figure 1. Ascentis Express 2.0 µm UHPLC columns are...
Richard A. Henry, Gaurang Parmar
Reporter US, Volume 32.2
Keywords: High performance liquid chromatography, Mass spectrometry, Pharmaceutical, Separation

Serum Lipidomics Profiling | Ascentis Express Fused-Core C18 Column

The following was generated with the assistance of an outside source using Sigma-Aldrich products. Technical content was generated and provided by:
Reporter US Volume 29.5
Keywords: Analytical Chemistry, Chromatography, Diffusion, Gas chromatography, High performance liquid chromatography, Liquid chromatography mass spectrometry, Mass spectrometry, Metabolites, Phase transitions, Separation

Related Content

Boosting HPLC Productivity: Nick the Hero [VIDEO]

Boosting HPLC Productivity Ascentis Express columns provide high-speed and high-efficiency separations that boost lab productivity. Learn about the features and benefits; become the "Nick the Hero" i...
Keywords: High performance liquid chromatography

Selection Guide for Ascentis® Express HPLC Columns

Ascentis Express C18 is the first choice for starting a new method. However, when a C18 doesn't give the desired separation or your sample contains compounds that are known to be difficult to retain ...
Keywords: High performance liquid chromatography, Separation, Supercritical fluid chromatography

Supelco HPLC Calculator for Isocratic or Gradient Method Transfer

Calculates conditions for transfer of an isocratic or gradient method from one HPLC column to another. Allows method scaling from microbore through preparative column range. Calculates time and solve...
Keywords: High performance liquid chromatography

Peer-Reviewed Papers
15

References

Related Products

guard cartridge

Product #

Description

Add to Cart

53509-U Ascentis® Express C8, 2.7 Micron Guard Cartridge, 2.7 μm particle size, L × I.D. 5 mm × 2.1 mm, pkg of 3 ea

required but not provided

Product #

Description

Add to Cart

53500-U Ascentis® Express Guard Cartridge Holder, for use with Ascentis Express Guard Columns, pk of 1

Technical Service:

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Bulk Ordering & Pricing:

Need larger quantities for your development, manufacturing or research applications?