• USA Home
  • 57300-U - SPME fiber assembly Polydimethylsiloxane (PDMS)

EMAIL THIS PAGE TO A FRIEND
57300-U Supelco

SPME fiber assembly Polydimethylsiloxane (PDMS)

df 100 μm, needle size 24 ga, for use with manual holder

  •  NACRES NB.21

Purchase

Properties

Related Categories Analytical/Chromatography, Polydimethylsiloxane (PDMS) fibers, non-polar, SPME Fiber Assemblies, SPME Fibers and Holders, Sample Preparation & Purification,
Quality Level   100
material   fused silica fiber
  plain red hub
needle size   24 ga
packaging   pkg of 3 ×  ea
df   100 μm
application(s)   solid phase microextraction (SPME): suitable
fiber L   1 cm
matrix active group   Polydimethylsiloxane (PDMS) coating
Featured Industry   Food and Beverages
compatibility   for analyte group volatiles (MW 60-275)
  for use with manual holder

Description

Application

Volatiles

Safety & Documentation

Safety Information

WGK Germany 
WGK 2
Flash Point(F) 
609.8 °F - closed cup
Flash Point(C) 
321 °C - closed cup

Documents

Certificate of Analysis (COA)

Please Enter a Lot Number

Frequently Asked Questions

Which document(s) contains shelf-life or expiration date information for a given product?
If available for a given product, the recommended re-test date or the expiration date can be found on the Certificate of Analysis.
How do I get lot-specific information or a Certificate of Analysis?
The lot specific COA document can be found by entering the lot number above under the "Documents" section.
How do I find price and availability?
There are several ways to find pricing and availability for our products. Once you log onto our website, you will find the price and availability displayed on the product detail page. You can contact any of our Customer Sales and Service offices to receive a quote. USA customers: 1-800-325-3010 or view local office numbers.
What is the maximum temperature for the 100 micron SPME fiber assembly Polydimethylsiloxane (PDMS), Product 57300-U?
The maximum temperature is 280°C. We recommend conditioning at 250°C.
Why should I use 100 micron SPME fiber assembly Polydimethylsiloxane (PDMS), Product 57300-U?
The 100 micron fiber is designed for low molecular weight or volatile compounds that require a thick coating for adsorption.
How is the fiber attached to the guide wire for SPME fiber assembly Polydimethylsiloxane (PDMS), Product 57300-U?
The fused silica fiber core is glued to the guide wire.
What is the Department of Transportation shipping information for this product?
Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.
My question is not addressed here, how can I contact Technical Service for assistance?
Ask a Scientist here.
My question is not addressed here, how can I contact Technical Service for assistance?
Ask a Scientist here.
Show more questions
Protocols & Articles

Articles

A Complete Solution for Forensic Analyses

Forensic science encompasses a very broad range of analytes and analytical techniques. Sigma-Aldrich offers the standards and analytical tools required for quantitative analyses in this expansive fie...
Patrick Myers
Reporter EU Volume 25
Keywords: Forensic, Gas chromatography, Help, High performance liquid chromatography, Metabolites, Methods, Sample preparations, Search, Separation, Solid phase extractions, Solid phase microextractions, Solvents, Tools

Development of a Method for Analysis of Phthalate Esters in Vegetable Oils

Phthalates (PAEs) are a group of synthetic compounds mainly used as plasticizers. They have been classified as endocrine-disrupting chemicals and potential human cancer- causing agents1. PAEs present...
Professor Luigi Mondello, Analytical Chemistry/Food Chemistry Laboratories, University of Messina, Italy
 
Keywords: Cancer, Capillary electrophoresis, Chromatography, Gas chromatography, Mass selective detector, Mass spectrometry, Sample preparations, Separation, Size-exclusion chromatography, Solid phase microextractions, Solvents

GC Analysis of Amphetamines in Plasma on SLB®-5ms (20 m x 0.18 mm I.D., 0.36 μm) after SPME using 100 μm PDMS Fiber, Fast GC Analysis

From our library of Articles, Sigma-Aldrich presents GC Analysis of Amphetamines in Plasma on SLB®-5ms (20 m x 0.18 mm I.D., 0.36 μm) after SPME using 100 μm PDMS Fiber, Fast GC Analysis
Keywords: Chromatography, Clinical, Forensic, Gas chromatography, Pharmaceutical, Purification, Solid phase microextractions

GC Analysis of Amphetamines in Urine on a 100%Methyl Column after SPME using 100 μm PDMS Fiber

From our library of Articles, Sigma-Aldrich presents GC Analysis of Amphetamines in Urine on a 100%Methyl Column after SPME using 100 μm PDMS Fiber
Keywords: Chromatography, Gas chromatography, Mass spectrometry, Pharmaceutical, Purification, Solid phase microextractions

GC Analysis of Chemical Signals from Spruce Seedlings (Healthy vs. Wounded) on a 5%Phenyl Column after SPME using 100 μm PDMS Fiber

From our library of Articles, Sigma-Aldrich presents GC Analysis of Chemical Signals from Spruce Seedlings (Healthy vs. Wounded) on a 5%Phenyl Column after SPME using 100 μm PDMS Fiber
Keywords: Agriculture, Chromatography, Gas chromatography, Solid phase microextractions

GC Analysis of Class 1 Residual Solvents on VOCOL® after SPME using 100 μm PDMS Fiber

From our library of Articles, Sigma-Aldrich presents GC Analysis of Class 1 Residual Solvents on VOCOL® after SPME using 100 μm PDMS Fiber
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Pharmaceutical, Size-exclusion chromatography, Solid phase microextractions

GC Analysis of Class 3 Residual Solvents on Equity®-1 after SPME using 100 μm PDMS Fiber

From our library of Articles, Sigma-Aldrich presents GC Analysis of Class 3 Residual Solvents on Equity®-1 after SPME using 100 μm PDMS Fiber
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Pharmaceutical, Size-exclusion chromatography, Solid phase microextractions

GC Analysis of Class 3 Residual Solvents on VOCOL® after SPME using 100 μm PDMS Fiber

From our library of Articles, Sigma-Aldrich presents GC Analysis of Class 3 Residual Solvents on VOCOL® after SPME using 100 μm PDMS Fiber
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Pharmaceutical, Size-exclusion chromatography, Solid phase microextractions

GC Analysis of Cocaine in Urine on a 100%Methyl Column after SPME using 100 μm PDMS Fiber

From our library of Articles, Sigma-Aldrich presents GC Analysis of Cocaine in Urine on a 100%Methyl Column after SPME using 100 μm PDMS Fiber
Keywords: Chromatography, Gas chromatography, Nitrogen phosphorus detector, Pharmaceutical, Purification, Solid phase microextractions

GC Analysis of Fragrance Compounds in Shampoo Base on a 100% Methyl Column after SPME using 100 μm PDMS Fiber

From our library of Articles, Sigma-Aldrich presents GC Analysis of Fragrance Compounds in Shampoo Base on a 100% Methyl Column after SPME using 100 μm PDMS Fiber
Keywords: Chromatography, Cosmetics, Gas chromatography, Mass selective detector, Purification, Solid phase microextractions

GC Analysis of Gasoline Residue in Arson Samples on a 100% Methyl Column after SPME using 100 μm PDMS Fiber

From our library of Articles, Sigma-Aldrich presents GC Analysis of Gasoline Residue in Arson Samples on a 100% Methyl Column after SPME using 100 μm PDMS Fiber
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification, Sample preparations, Size-exclusion chromatography, Solid phase microextractions

GC Analysis of Organochlorine Pesticides in Water on SPB®-5 after SPME using 100 μm PDMS Fiber

From our library of Articles, Sigma-Aldrich presents GC Analysis of Organochlorine Pesticides in Water on SPB®-5 after SPME using 100 μm PDMS Fiber
Keywords: Chromatography, Electron capture detector, Environmental, Gas chromatography, Metabolites, Pesticides, Purification, Size-exclusion chromatography, Solid phase microextractions

GC Analysis of Organophosphorus Pesticides (OP-Pest) on a 5% Phenyl Column after SPME using 100 μm PDMS Fiber

From our library of Articles, Sigma-Aldrich presents GC Analysis of Organophosphorus Pesticides (OP-Pest) on a 5% Phenyl Column after SPME using 100 μm PDMS Fiber
Keywords: Chromatography, Environmental, Gas chromatography, Mass spectrometry, Purification, Solid phase microextractions

GC Analysis of PCB Congeners in Stream Sediment on SPB®-Octyl after SPME using 100 μm PDMS Fiber

From our library of Articles, Sigma-Aldrich presents GC Analysis of PCB Congeners in Stream Sediment on SPB®-Octyl after SPME using 100 μm PDMS Fiber
Keywords: Chromatography, Environmental, Gas chromatography, Purification, Solid phase microextractions

GC Analysis of Phthalate Esters in Corn Oil (Spiked) on SLB®-5ms after SPME with a 100 μm PDMS Fiber

From our library of Articles, Sigma-Aldrich presents GC Analysis of Phthalate Esters in Corn Oil (Spiked) on SLB®-5ms after SPME with a 100 μm PDMS Fiber
Keywords: Agriculture, Chromatography, Gas chromatography, Mass spectrometry, Purification, Solid phase microextractions

GC Analysis of Phthalate Esters in Extra Virgin Olive Oil (Spiked) on SLB®-5ms after SPME using 100 μm PDMS Fiber

From our library of Articles, Sigma-Aldrich presents GC Analysis of Phthalate Esters in Extra Virgin Olive Oil (Spiked) on SLB®-5ms after SPME using 100 μm PDMS Fiber
Keywords: Chromatography, Gas chromatography, Mass spectrometry, Phase transitions, Separation, Size-exclusion chromatography, Solid phase microextractions

GC Analysis of Residual Solvents on SPB®-624 after SPME using 100 μm PDMS Fiber

From our library of Articles, Sigma-Aldrich presents GC Analysis of Residual Solvents on SPB®-624 after SPME using 100 μm PDMS Fiber
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Pharmaceutical, Purification, Sample preparations, Solid phase microextractions

GC Analysis of Tricyclic Antidepressants in Urine on a 100%Methyl Column after SPME using 100 μm PDMS Fiber

From our library of Articles, Sigma-Aldrich presents GC Analysis of Tricyclic Antidepressants in Urine on a 100%Methyl Column after SPME using 100 μm PDMS Fiber
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Pharmaceutical, Purification, Solid phase microextractions

GC Analysis of Volatiles in Limoncello on SLB®-5ms after SPME using a 100 μm PDMS Fiber

From our library of Articles, Sigma-Aldrich presents GC Analysis of Volatiles in Limoncello on SLB®-5ms after SPME using a 100 μm PDMS Fiber
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Mass spectrometry, Purification, Sample preparations, Solid phase microextractions

GC Analysis of Volatiles in Water on SPB®-1 after SPME using 100 μm PDMS Fiber

From our library of Articles, Sigma-Aldrich presents GC Analysis of Volatiles in Water on SPB®-1 after SPME using 100 μm PDMS Fiber
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification, Solid phase microextractions

SPME-GC-MS Determination of Phthalate Esters in Ramen Noodle Flavor Packets

In June of 2011, food safety authorities in Hong Kong found phthalate ester contamination in a variety of imported food and drink products1. Among these foods were several brands of ramen noodle kits...
Katherine K. Stenerson
Reporter US, Volume 30.1
Keywords: Chromatography, Food Safety, Gas chromatography, Gas chromatography mass spectrometry, Mass selective detector, Mass spectrometry, Sample preparations, Size-exclusion chromatography, Solid phase microextractions

Related Content

Fundamentos basicos de microextraccion en fase solida (SPME) y sus aplicaciones [Webinar]

En este webinar presentamos los fundamentos básicos de microextracción en fase sólida (SPME) y sus aplicaciones. SPME es una técnica para análisis de compuestos volátiles y semi-volátiles, fácil de u...
Keywords: Solid phase microextractions

Peer-Reviewed Papers
15

References

Related Products

Technical Service:

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Bulk Ordering & Pricing:

Need larger quantities for your development, manufacturing or research applications?