Product Category
Chemical Synthesis(1)
Labware(1)
Materials Science(3)

Available for Sale

Search term:"Glycine"

Compare Products: Select up to 4 products.

*Please select more than one item to compare

7 matches found for Glycine

HPLC Analysis of Mouse Monoclonal Antibodies (MAb) on TSKgel® Ether-5PW

column TSKgel Ether-5PW, 7.5 cm x 8 mm I.D., 10 µm particles (814014) mobile phase [A] 0.05 M sodium phosphate, pH 7.0, 2 M ammonium sulfate, 1 M glycine; [B] 0.05 M sodium phosphate, pH 7.0, 1 M glycine gradient linear gradient as shown on the figure flow rate 1 mL/min detector UV, 280 nm Categorie...

Determination of Water Content in Glycine Using Karl Fischer Titration

Carboxylic acids Carboxylic acids Most carboxylic acids can be analysed relatively easily following standard KF titration methods. Due to their weakly acidic properties they exhibit only a slight effect on the pH of the KF solution. Only the stronger acids require neutralisation or buffering of the ...

HPLC Analysis of the Peptide Glycine-Leucine-Alanine Enantiomers on Astec® CHIROBIOTIC® TAG

column CHIROBIOTIC TAG, 25 cm x 4.6 mm I.D., 5 µm particles (14024AST) column temp. 25 °C mobile phase [A] 5 mM ammonium acetate, pH 4.1; [B] acetonitrile; (35:65, A:B) flow rate 1 mL/min sample 2 mg/mL in methanol injection 5 µL detector UV, 220 nm Categories Analytical Chromatography, Chiral Appli...

Classical Silica HPTLC Plates

Our high performance thin-layer chromatography (HPTLC) plates are the perfect choice for quantitative separation using instrumental HPTLC. The optimized, smaller particles enable significant higher speed, more efficiency and better sensitivity than classical TLC plates. The parallel separation of ma...

Analytical Method: Analytical Quality Assurance, Standard for Nitrogen (total)

Reagents: Cat.No. 104201 Glycine for analysis Cat.No. 116754 Water for analysis Preparation of a standard solution: Dissolve 5.36 g of glycine with distilled water in a calibrated or conformity-checked 1000-ml volumetric flask and make up to the mark with distilled water. The stock solution prepared...

GC Analysis of Amino Acids (as TBDMS Derivatives) on SLB®-5ms (20 m x 0.18 mm I.D., 0.18 μm), Fast GC Analysis

column SLB-5ms, 20 m x 0.18 mm I.D., 0.18 µm (28564-U) oven 100 °C (1 min), 35 °C/min to 290 °C (3 min), 40 °C/min to 360 °C carrier gas helium, 1 mL/min, constant sample TBDMS derivatives of amino acids, each approximately 23 ug/mL injection 0.5 µL, splitless (1.0 min) liner 2 mm I.D., straight inj...

Application Notes for Karl Fischer Titration

Determination of water content according to Karl Fischer is rapid, accurate and reliable. KF titration is therefore the method of choice in quality and in-process control, production and research & development. Using the Karl Fischer titration with Aquastar® reagents, the water content of gases, liq...