Area of Interest
Miscellaneous(1793)
SAFC(1)
Technical Documents(199)
Technical Service(14)
Document Category
Aldrichimica Acta(9)
Application Note(480)
Brochure(486)
Bulletin(220)
Datasheet(375)
Enzyme Assay(2)
General Information(643)
Instruction(37)
Method(8)
Poster(196)
Product Information Sheet(233)
Technical Ad(1)
The Reporter(286)
Usage(1)
Vector(1)

Available for Sale

Search term:"Supelco"

Compare Products: Select up to 4 products.

*Please select more than one item to compare

2978 matches found for Supelco

Supelco SLB®-IL60 Ionic Liquid GC Columns (870 KB)

Better High Temperature Stability Supelco SLB ®-IL60 Ionic Liquid GC Columns Benefits of higher temperature when performing GC include decreased analysis times, elevated bake-out to remove large non-target compounds, and analysis of additional higher boiling compounds. The SLB-IL60 column is stable ...

Supelco SLB®-IL60 Ionic Liquid GC Columns (1 MB)

Supelco SLB ®-IL60 Ionic Liquid GC Columns The SLB-IL60 column is able to undergo the same analyte-phase interactions as polyethylene glycol (PEG) columns, but at different relative amounts. Based on its unique phase structure, the SLB-IL60 column is also able to undergo additional interactions that...

Supelco SLB®-IL60 Ionic Liquid GC Columns (1 MB)

Lower FID Bleed Supelco SLB ®-IL60 Ionic Liquid GC Columns Higher temperature GC columns are desirable, as they may allow decreased analysis times, elevated bake-out to remove large non-target compounds, and analysis of higher boiling compounds. However, higher oven temperatures also tend to acceler...

Supelco SLB®-IL60 Ionic Liquid GC Columns (800 KB)

Stability to Loss of Carrier Gas Flow Supelco SLB ®-IL60 Ionic Liquid GC Columns Hydroxyl (-OH) functional groups are abundant in polyethylene glycol (PEG) stationary phases. These active moieties can be oxidized when exposed to low levels of moisture and/or oxygen, contributing to degradation of th...

Supelco Reporter, Volume 31.3 (3 MB)

Applications Newsletter Volume 31.3 pg. 12 CHIR AL L C�MS / MS OF D - AND L -2 �H Y DRO X Y GL UT ARIC A CID BIOM ARKERS pg. 19 SA MPLING TECHNIQUE FOR QU ALIT A TIVE V OL A TILE HEADSP A CE OUT GASSING FROM SOLID M A TRICES pg. 3 Simplify and Reduce Variability During SPE Cleanup of Wheat Extracts ...

Supelco Reporter Volume 32.1 (5 MB)

pg. 12 FAST EXTRACTION AND LOW LEVEL DETECTION OF CHLORAMPHENICOL IN SHRIMP pg. 22 ONLINE SPE/LC-MS METHOD FOR THE RAPID ANALYSIS OF THYROID HORMONES IN PLASMA pg. 3 Faster Protein and Peptide Liquid Chromatography Applications Newsletter Volume 32.1 sigma-aldrich.com/analytical Reporter 32.1 | 2 Ta...

Supelco Reporter, Volume 29.4 (2 MB )

Liquid Chromatography Sample Preparation Gas Chromatography Standards Accessories Chiral Chromatography Reporter Volume 29.4 Serving the Analytical World Our customers represent an astounding diversity in geography, markets, samples, job functions, whether they come from academia, industry, governme...

Supelco 37 Component FAME Mix - CRM47885 (2 MB)

如需订购 色谱柱 , CRM47885 请致电 800-819-3336 (固话) / 400-620-3333 (手机) 或发送邮件至 Email: OrderCN@sial.com (CRM47791, CRM47792)

Supelco Reporter, Volume 29.5 (2 MB )

Liquid Chromatography Sample Preparation Gas Chromatography Standards Accessories Chiral Chromatography Reporter Volume 29.5 High Resolution LC-MS Profiling of Serum Lipids using Ascentis Express Serum lipidomics - a study of blood lipid composition 2 Reporter Visit us on the web at sigma-aldrich.co...

Supelco Reporter Vol. 33.1 (3 MB)

Applications Newsletter Volume 33.1 pg. 3 Evaluation of Seven Ionic Liquid Capillary GC Columns sigma-aldrich.com/analytical Reporter 33.1 | 2 Reporter Volume 33.1 Supelco, an Integral Part of GC Technology Since 1966 Dear Colleague: Upon the birth of gas chromatography (GC) in 1952, the user was re...

Supelco Reporter, Volume 34.1 (3 MB)

Applications Newsletter Volume 34.1 pg. 3 Improved Chemical Profiling of Brazilian Cachaça Using Matrix-Compatible SPME Fibers and an Ionic Liquid GC Column sigma-aldrich.com/analytical Reporter 34.1 | 2 Environmental Reporter Volume 34.1 Uncover the Unseen in the Green Dear Colleague, Regulatory ag...

Supelco Reporter, Volume 30.1 (2 MB )

Pharmaceutical & Bioanalysis Food & Beverage Analysis Environmental Analysis Chromatographic Purification Research & Technology Reporter Volume 30.1 Rapid Determination of Packaging Contaminants in Food & Beverages Food packaging is a major source of exposure to BPA and phthalates, both endocrine-di...

Supelco Analytical Products (18 MB)

Accuracy. Precision. Consistency. The life science business of Merck operates as MilliporeSigma in the U.S. and Canada. Whether you are using chromatography, spectroscopy, titration, or any other analytical chemistry technique, you can depend on accurate results, every time. Spectroscopy & Spectrome...

Supelco Specialty Carbon Adsorbents (858 KB)

Selection Guidelines Carbon Adsorbent Sampler Kits Carbon Molecular Sieves Spherical Graphitized Polymer Carbons Graphitized Carbon Blacks Custom Capabilities Supelco® Specialty Carbon Adsorbents High-Tech Materials Engineered for Applications of This World and Beyond! 3 sigma-aldrich.com/carbon Sup...

Supelco Columns for USP Methods (172 KB)

HPLC Packings USP Code Description Recommended Packing  L1 Octadecyl silane chemically bonded to porous or non-porous silica or ceramic micro-particles, 1.5 to 10 μm in diameter, or a monolithic rod. • Titan™ C18 • Ascentis® C18 • Ascentis Express C18 • BIOshell ™ Peptide C18 • Discovery® C18 • Dis...

Supelco FLM Thermal Desorption Tube (443 KB)

This Data Sheet Contains Important Information About The Product. Supelco® FLM™ Fenceline Monitoring Deactivated Stainless Steel Thermal Desorption Tube Packed with Carbopack™ X T714009 ©2015 Sigma-Aldrich Co. SUPELCO Bellefonte, PA P1001592 P1001593 Applications l EPA Method 325 A/B - Fenceline Mon...

Supelco SLB®-IL60 Ionic Liquid GC Columns (1 MB)

Improved Resolution Supelco SLB ®-IL60 Ionic Liquid GC Columns The variety of analyte-phase interactions possible with the SLB-IL60 column can be leveraged to provide improved separations. This is especially true for complex mixtures comprised of compounds with varying functionality. Polyethylene gl...

Supelco Reporter, Volume 31.2 (3 MB)

Applications Newsletter Volume 31.2 pg. 12 INCREASE REMOVAL OF FAT AND PIGMENT FROM AVOCADO EXTRACTS pg. 18 LC-MS ANALYSIS OF WARFARIN IN PLASMA SAMPLES Introducing UHPLC Columns Setting a New Performance Standard pg. 3 sigma-aldrich.com/analytical Reporter 31.2 | 2 Table of Contents Pharmaceutical ...

Supelco Reporter, Volume 29.3 (1 MB )

Liquid Chromatography Sample Preparation Gas Chromatography Standards Accessories Chiral Chromatography Reporter Volume 29.3 Improved Detection and Analysis of Airborne Contaminants Detection and identification of airborne pollutants leads to better quality of life. 2 Reporter Visit us on the web at...

Supelco Reporter, Volume 29.2 (1 MB )

Liquid Chromatography Sample Preparation Gas Chromatography Standards Accessories Chiral Chromatography Reporter Volume 29.2 Fast and Accurate LC-MS Analysis of 25-Hydroxyvitamin D Vitamin D is produced in the skin after exposure to sunlight. It improves the quality of life by promoting proper bone ...

Supelco Reporter Vol. 27.4 (1 MB )

Reporter Volume 27.4 During the last decade, analysis of food and beverage products for both harmful and beneficial compounds has become a topic of major interest. Food & Beverage Analysis • • Liquid Chromatography • • Sample Handling • • Gas Chromatography • • Standards • • Accessories • • Chiral C...

Supelco Reporter Food & Beverage Supplement to Volume 33.4 (4 MB)

Applications Newsletter Food and Beverage Supplement to Volume 33.4 pg. 3 Development of a Method for Analysis of Phthalate Esters in Vegetable Oils pg. 13 IDENTIFICATION AND QUANTIFICATION OF TRIACYLGLYCEROLS IN EXPIRED DAIRY PRODUCTS AND SEAFOOD USING NARP-HPLC-APCI-MS pg. 2 2 ANALYSIS OF POLYCHLO...

Supelco Chemical Reference Material Packaging Services (171 KB )

Supelco Chemical Reference Material Packaging Services Offering precision, small unit packaging for preserving material integrity sigma-aldrich.com/supelco JLI T407062 Supelco Chemical Reference Material Packaging Services For more information about how our materials repackaging service can help you...

Supelco Reporter, Vol 31.1 (3 MB)

pg. 12 ANALYSIS OF ANTIARRHYTHMIC CARDIAC DRUGS IN PLASMA pg. 20 PERFORMANCE COMPARISON OF STORAGE CONTAINERS TDS 3™ Analysis of Pesticides by QuEChERS and SPE pgs. 6 &8 Applications Newsletter Volume 31.1 sigma-aldrich.com/analytical Reporter 31.1 | 2 Table of Contents Pharmaceutical Benefits of La...

Supelco Petroleum Guide Update (723 KB )

1 SUPELCO Bulletin 858 Bulletin 858C Petroleum/Chemicals Application Guide 0 8 16 24 40 32 48 56 64 72 88 80 96 104 Min 1 2 3 4 5 6 7 8 9 10 12 11 Column and conditions: see Figure A. 796-0092 1 2 4 6 0 0 26 4 8 10 Min Min 1 3 4 5 7 Butane Lighter Fuel Petroleum Ether 713-0763 Figure 2. Unleaded Gas...

Supelco Analytical Products (18 MB)

Accuracy. Precision. Consistency. The life science business of Merck KGaA, Darmstadt, Germany operates as MilliporeSigma in the U.S. and Canada. Whether you are using chromatography, spectroscopy, titration, or any other analytical chemistry technique, you can depend on accurate results, every time....

Supelco Reporter, Volume 33.4 (4 MB)

Applications Newsletter Volume 33.4 pg. 26 PASSIVE AIR SAMPLING TUBES FOR US EPA METHOD 325 pg. 3, 23, 28 Emergence of Three New GC Columns pg. 11 HIGH RESOLUTION AND HIGH EFFICIENCY SEPARATIONS OF MABS AND ADCS USING PROTEOMIX HIC COLUMNS SILICA COLUMN sigma-aldrich.com/analytical Reporter 33.4 | 2...

Supelco SLB-IL60 Ionic Liquid GC Columns: Lower FID Bleed (853 KB)

Reporter 33.3 | 30 Supelco SLB ®-IL60 Ionic Liquid GC Columns: Lower FID Bleed Leonard M. Sidisky, R&D Manager; Katherine K. Stenerson, Applications Chemist; and Michael D. Buchanan, Product Manager mike.buchanan@sial.com The SLB-IL60 gas chromatography (GC) column is based on an ionic liquid statio...

Supelco Reporter, Volume 28.5

Liquid Chromatography Sample Preparation Gas Chromatography Standards Accessories Chiral Chromatography Reporter Volume 28.5 Separation of Closely Related Compounds Ascentis Express F5 HPLC columns, due to enhanced shape selectivity, provide the separation of closely related compounds. 2 Reporter Vi...

Supelco Reporter, Volume 30.3 (3 MB)

The Next Evolution of Isocyanate Sampling ASSET™ EZ4-NCO Dry Sampler Volume 30.3 3 pg. 11 ILLICIT BATH SALTS IN URINE pg. 24 PESTICIDE DETERMINATION IN ORANGES Supel QuE QuEChERS pg. 3 sigma-aldrich.com/analytical Reporter 30.3 | 2 Reporter Reporter is published five times a year by Supelco, 595 Nor...