HPLC Analysis of Cosmetic Preservatives on Ascentis® Express C18 (1.2 mL/min)

column Ascentis Express C18, 7.5 cm x 3 mm I.D., 2.7 µm particles (53812-U) column temp. 35 °C mobile phase [A] water; [B] methanol; (55:45, A:B) flow rate 1.2 mL/min sample methyl-, benzylparaben, 50 mg/L; ethylparaben, 30 mg/L; propyl-, butylparaben, 100 mg/L; 2-phenoxyethanol, 1.5 g/L; 1-phenoxy-...

TLC Analysis of a cosmetic active on HPTLC Silica gel 60 F254 (analyte set 2)

sample preparation 1 g cosmetic samples was stirred with 10 ml 1-Propanol at room temperature and filtered with a 0.45 μm syringe filter. Application with CAMAG ATS4, 6 mm bandwise. detector 254, 366 nm and white light (Derivatisation: Anisaldehyde- sulfuric acid) eluent [A] petroleum benzine; [B] 1...

HPLC Analysis of Cosmetic Preservatives on Ascentis® Express RP-Amide at Elevated Flow and Temperature (1.2 mL/min)

column Ascentis Express RP-Amide, 10 cm x 3 mm I.D., 2.7 µm particles (53918-U) column temp. 50 °C mobile phase [A] water; [B] methanol; (60:40, A:B) flow rate 1.2 mL/min sample methyl-, benzylparaben, 50 mg/L; ethylparaben, 30 mg/L; propyl-, butylparaben, 100 mg/L; 2-phenoxyethanol, 1.5 g/L; 1-phen...

HPLC Analysis of Cosmetic Preservatives on Ascentis® Express RP-Amide at Elevated Temperature (0.6 mL/min)

column Ascentis Express RP-Amide, 10 cm x 3 mm I.D., 2.7 µm particles (53918-U) column temp. 50 °C mobile phase [A] water; [B] methanol; (60:40, A:B) flow rate 0.6 mL/min sample methyl-, benzylparaben, 50 mg/L; ethylparaben, 30 mg/L; propyl-, butylparaben, 100 mg/L; 2-phenoxyethanol, 1.5 g/L; 1-phen...

HPLC Analysis of Cosmetic Preservatives on Ascentis® Express RP-Amide

column Ascentis Express RP-Amide, 10 cm x 3 mm I.D., 2.7 µm particles (53918-U) column temp. 50 °C mobile phase [A] water; [B] methanol; (60:40, A:B) flow rate 0.6 mL/min pressure 2900 psi (200 bar) sample methyl-, benzylparaben (50 mg/L), ethylparaben (30 mg/L), propyl-, butylparaben (100 mg/L), 2-...

HPLC Analysis of Cosmetic Preservatives on Ascentis® Express C18 (0.6 mL/min)

column Ascentis Express C18, 7.5 cm x 3 mm I.D., 2.7 µm particles (53812-U) column temp. 35 °C mobile phase [A] water; [B] methanol; (55:45, A:B) flow rate 0.6 mL/min sample methyl-, benzylparaben, 50 mg/L; ethylparaben, 30 mg/L; propyl-, butylparaben, 100 mg/L; 2-phenoxyethanol, 1.5 g/L; 1-phenoxy-...

TLC Analysis Of a Cosmetic Active on HPTLC Silica Gel 60 F254 (analyte set 1)

detector UV, 254 nm (Identification by coupling the TLC – MS Interface (CAMAG) with Microsaic 3500 MiD mass spectrometer (+)-ESI mode. Eluent: Acetonitrile / Water (95/5) + 0.1% TFA) eluent [A] petroleum benzine; [B] acetone; (8:2, A:B) chamber normal chamber without chamber saturation migration dis...

TLC Analysis Of Vitamin C Derivates From Cosmetic Formulation on HPTLC Silica gel 60 F254s

sample preparation 1 g cosmetic formulation (1% and 2% active) was stirred in 10 ml THF for 15 min and filtered over a 0.45 μm syringe filter. Application by CAMAG ATS4 6 mm bandwise. sample 0.150 μL detector UV, 254 nm (Identification by coupling the TLC – MS Interface (CAMAG) with the Advion expre...

Sample prep-free determination of Arginine and Taurine in shampoo by using TLC-MS

The application of modern thin-layer chromatography (TLC) offers a lot of advantages especially in the field of cosmetics. The ingredients can usually be separated directly from complex matrices and many samples can be analysed quickly and simultaneously under exactly the same conditions. Below the ...

Selecting a GC Column for Specific Industries/Applications

We know that only the most accurate analytical products will do. That’s why we offer the Supelco portfolio of analytical GC columns, providing you the accuracy, precision and consistency you need. Gas chromatography, first established in the 1950′s, is a mature analytical technique with many establi...

GCxGC Analysis of Allergens in Perfume Sample 2 on SLB®-5ms x SLB®-35ms, Non-Polar to Polar Strategy

column (2D)SLB-35ms, 5 m x 0.25 mm I.D., 0.25 µm (29804-U) column (1D) SLB-5ms, 20 m x 0.18 mm I.D., 0.18 µm (28564-U) oven (modulator) stainless steel accumulation loop measuring 20 cm x 0.71 mm O.D. x 0.51 mm I.D.; modulation period: 5.4 sec (accumulation period 4.9 sec, injection period 0.5 sec) ...

GC Analysis of Methoxyphenols on SLB®-IL76i

column SLB®-IL76i, 30 m x 0.25 mm I.D., 0.20 μm (29869-U) oven 180 °C (1 min), 20 °C/min to 240 °C (4 min) carrier gas helium, 30 cm/sec injection 1 μL, 100:1 split liner 3.5 mm I.D., split/splitless, wool packed design inj. temp. 250 °C detector MSD, full scan, m/z 50-500 MSD interface 270 °C Analy...

Determination of Water Content in Shower gel Using Karl Fischer Titration

Cosmetics Cosmetics Cosmetics on an aqueous and alcoholic basis can be titrated without problems according to the Karl Fischer (KF) method. Due to the often high water concentration of the emulsions small samples are required. The accuracy of analysis is determined through exact sampling, weighing a...

Unmodified Silica TLC Plates

TLC plates manufactured by Merck KGaA, Darmstadt Germany allow reliable, fast and economical analysis of a great range of substances in pharmaceutical, environmental, food and beverage, cosmetics and many more applications. Thanks to a highly standardized production process and an outstanding qualit...

GC Analysis of Antioxidants on SAC™-5

column SAC-5, 30 m x 0.25 mm I.D., 0.25 µm (24156) oven 200 °C carrier gas helium, 30 cm/sec sample 200 µg/mL each component injection 2 µL, split 100:1 detector FID, 250 °C Categories Analytical Chromatography, GC Applications, Antioxidants Featured Industry Cosmetics, Personal Care, and Cleaning P...

Determination of Water Content in Oil of tangerines Using Karl Fischer Titration

Cosmetics, Foodstuffs Cosmetics Cosmetics on an aqueous and alcoholic basis can be titrated without problems according to the Karl Fischer (KF) method. Due to the often high water concentration of the emulsions small samples are required. The accuracy of analysis is determined through exact sampling...

UHPLC Analysis of Benzoyl Peroxide from Clean & Clear® Continuous Control Acne Cleanser on Purospher® STAR RP-18e Hibar® HR

sample preparation Clean & Clear® continuous control acne cleanser at 100 mg/mL in 30:70 acetonitrile: 5 mM potassium phosphate pH 3.0 in water. (See "Sample Prep" at Description Text) column Purospher STAR RP-18e Hibar HR, 10 cm x 2.1 mm I.D., 2.0 μm, 120Å (1.50648.0001) mobile phase [A] 5 mM potas...

HPLC Analysis of Hydrocortisone in Topical Cream on Discovery® HS C18 after SPE using Discovery® DSC-Si

sample preparation SPE (Solid Phase Extraction) SPE tube/cartridge Discovery DSC-Si, 500 mg/3 mL (52695-U) condition 1 mL hexane:ethyl acetate (2:1, v/v) sample addition hydrocortisone topical hand cream in hexane:ethylacetate sample addition 1 mL washing 1 mL hexane:ethyl acetate (2:1, v/v) elution...

Determination of Water Content in Moisturising lotion Using Karl Fischer Titration

Cosmetics Cosmetics Cosmetics on an aqueous and alcoholic basis can be titrated without problems according to the Karl Fischer (KF) method. Due to the often high water concentration of the emulsions small samples are required. The accuracy of analysis is determined through exact sampling, weighing a...

GC Analysis of Phthalate Esters in Perfume on SLB®-5ms (20 m x 0.18 mm I.D., 0.18 μm), Fast GC Analysis

column SLB-5ms, 20 m x 0.18 mm I.D., 0.18 µm (28564-U) oven 60 °C (1 min), 10 °C/min to 330 °C (10 min) carrier gas helium, 0.6 mL/min, constant sample cologne sample spiked at 100 µg/mL with various phthalate esters liner 4 mm ID focus liner with taper inj. temp. 250 °C Analysis Note Phthalate este...

HPLC Analysis of Sunscreens on Ascentis® C18

column Ascentis C18, 15 cm x 4.6 mm I.D., 5 µm particles (581324-U) column temp. 35 °C mobile phase [A] water, [B] methanol, (88:12, A:B) flow rate 1 mL/min sample 50 µg/mL in mobile phase injection 10 µL detector UV, 305 nm Categories Analytical Chromatography, Ketones, Esters Featured Industry Cos...

Determination of Water Content in Shampoo Using Karl Fischer Titration

Cosmetics Cosmetics Cosmetics on an aqueous and alcoholic basis can be titrated without problems according to the Karl Fischer (KF) method. Due to the often high water concentration of the emulsions small samples are required. The accuracy of analysis is determined through exact sampling, weighing a...

Determination of Water Content in Toothpaste Using Karl Fischer Titration

Cosmetics Cosmetics Cosmetics on an aqueous and alcoholic basis can be titrated without problems according to the Karl Fischer (KF) method. Due to the often high water concentration of the emulsions small samples are required. The accuracy of analysis is determined through exact sampling, weighing a...

Determination of Water Content in Cinnamon leaf oil Using Karl Fischer Titration

Cosmetics, Foodstuffs Cosmetics Cosmetics on an aqueous and alcoholic basis can be titrated without problems according to the Karl Fischer (KF) method. Due to the often high water concentration of the emulsions small samples are required. The accuracy of analysis is determined through exact sampling...

Determination of Water Content in Polysorbate 80 (Tween 80) Using Karl Fischer Titration

Cosmetics, Foodstuffs, Pharmaceuticals Cosmetics Cosmetics on an aqueous and alcoholic basis can be titrated without problems according to the Karl Fischer (KF) method. Due to the often high water concentration of the emulsions small samples are required. The accuracy of analysis is determined throu...

GC Analysis of Allergens in Perfume on SLB®-5ms (10 m x 0.10 mm I.D., 0.10 μm), Fast GC Analysis

column SLB-5ms, 10 m x 0.10 mm I.D., 0.10 µm (28465-U) oven 40 °C, 50 °C/min to 320 °C carrier gas hydrogen, 81.5 cm/sec constant sample neat perfume injection 0.2 µL in the split mode (500:1) inj. temp. 320 °C detector FID, 320 °C Categories Analytical Chromatography, GC Applications, Allergens Fea...

TLC and HPTLC Plates with Concentrating Zone

Quick and Easy Application of Large Sample Volumes Our concentrating zone plates are based on the different properties of two silica adsorbents: an inert, large-pore concentrating adsorbent where the samples are applied; and a selective separation layer. Independent of the shape, size or position of...

UHPLC Analysis of Benzoyl peroxide from Neutrogena® Rapid Clear® stubborn acne spot gel on Purospher® STAR RP-18e Hibar® HR

sample preparation 1 gram of Neutrogena® Rapid Clear® Stubborn Acne Spot Gel (10% benzoyl peroxide). (See "Sample Prep" at Description Text.) column Purospher STAR RP-18e Hibar HR, 10 cm x 2.1 mm I.D., 2.0 μm, 120Å (1.50648.0001) mobile phase [A] 5 mM Potassium Phosphate, pH 3.0 with phosphoric acid...

Determination of Water Content in Moisturizer Using Karl Fischer Titration

Cosmetics Cosmetics Cosmetics on an aqueous and alcoholic basis can be titrated without problems according to the Karl Fischer (KF) method. Due to the often high water concentration of the emulsions small samples are required. The accuracy of analysis is determined through exact sampling, weighing a...

GC Analysis of Menthol Enantiomers on α-DEX™ 120

column alpha-DEX 120, 30 m x 0.25 mm I.D., 0.25 µm (24310) oven 110 °C carrier gas helium, 20 cm/sec sample 0.5 mg/mL each component injection 1 µL, 100:1 split detector FID, 300 °C Categories Analytical Chromatography, GC Applications, Alcohols, Enantiomers Featured Industry Cosmetics, Personal Car...