EMAIL THIS PAGE TO A FRIEND

Product Category
Chemical Synthesis(19)
Labware(2)
Materials Science(62)

view products:

Compare products:

Select the checkbox on up to 4 items, then click 'compare' for a detailed product comparison

*Please select more than one item to compare

    Search term:"cosmetic"

    106 matches found for cosmetic

    GC Analysis of a QC Test Mix Containing Water on Watercol 1460, 96 °C

    column Watercol 1460, 30 m x 0.25 mm I.D., 0.20 µm (29695-U) oven 96 C carrier gas helium, 26 cm/sec sample 6 analytes in acetone, each at 1 mg/mL except water (at 0.5 mg/mL) injection 1 µL, 100:1 split liner 4 mm I.D., split type, cup design inj. temp. 250 °C detector TCD, 200 °C Analysis Note The ...

    GC Analysis of Repeat Injections of a QC Test Mix Containing Water on Watercol™ 1900, 96 °C

    column Watercol 1900, 30 m x 0.25 mm I.D., 0.20 µm (29761-U) oven 96 C carrier gas helium, 26 cm/sec sample 6 analytes in acetone, each at 1 mg/mL except water (at 0.5 mg/mL) injection 1 µL, 100:1 split liner 4 mm I.D., split type, cup design inj. temp. 250 °C detector TCD, 200 °C Analysis Note The ...

    GC Analysis of Water in Ethanol (0.25%Standard) on Watercol™ 1460

    column Watercol 1460, 30 m x 0.25 mm I.D., 0.20 µm; two identical columns installed in the same inlet, each going to a separate detector (29695-U) oven 45 °C (4 min), 5 °C/min to 75 °C, 10 °C/min to 220 °C (10 min) carrier gas helium, 20 cm/sec (measured in each column at an oven temperature of 135 ...

    GC Analysis of Water in Ethanol (0.5%Standard) on Watercol™ 1460

    column Watercol 1460, 30 m x 0.25 mm I.D., 0.20 µm (29695-U) oven 60 °C (12 min) carrier gas helium, 26 cm/sec sample water at 0.05% (v/v) in ethanol injection 0.5 µL, 100:1 split liner 4 mm I.D., split type, cup design inj. temp. 250 °C detector TCD, 200 °C Analysis Note The "Watercol" series of io...

    GC Analysis of Water in a 60-Component Solvent Mix on Watercol™ 1910

    column Watercol 1910, 30 m x 0.25 mm I.D., 0.20 µm; two identical columns installed in the same inlet, each going to a separate detector (29711-U) oven 50 °C (1 min), 5 °C/min to 180 °C (5 min) carrier gas helium, 25 cm/sec (measured in each column at an oven temperature of 125 °C) sample mixture of...

    GC Analysis of Water in Ethanol (0.5%Standard) on Watercol™ 1910

    column Watercol 1910, 30 m x 0.25 mm I.D., 0.20 µm (29711-U) oven 80 °C (10 min) carrier gas helium, 26 cm/sec sample water at 0.05% (v/v) in ethanol injection 0.5 µL, 100:1 split liner 4 mm I.D., split type, cup design inj. temp. 250 °C detector TCD, 200 °C Analysis Note The "Watercol" series of io...

    GC Analysis of a QC Test Mix Containing Water on Watercol 1910, 96 °C

    column Watercol 1910, 30 m x 0.25 mm I.D., 0.20 µm (29711-U) oven 96 C carrier gas helium, 26 cm/sec sample 6 analytes in acetone, each at 1 mg/mL except water (at 0.5 mg/mL) injection 1 µL, 100:1 split liner 4 mm I.D., split type, cup design inj. temp. 250 °C detector TCD, 200 °C Analysis Note The ...

    GC Analysis of Water (0.1-100%Calibration Curve) on Watercol™ 1460

    column Watercol 1460, 30 m x 0.25 mm I.D., 0.20 µm (29695-U) oven 60 °C (12 min) carrier gas helium, 26 cm/sec sample 7 standards, water at 0.1, 0.5, 20, 40, 60, and 80% (v/v), each in ethanol, and water at 100% injection 0.5 µL for 0.1-60% water, 0.1 µL for 80-100% water, 100:1 split liner 4 mm I.D...

    GC Analysis of Repeat Injections of a QC Test Mix Containing Water on Watercol™ 1460, 110 °C

    column Watercol 1460, 30 m x 0.25 mm I.D., 0.20 µm (29695-U) oven 110 °C carrier gas helium, 26 cm/sec sample 6 analytes in acetone, each at 1 mg/mL except water (at 0.5 mg/mL) injection 1 µL, 100:1 split liner 4 mm I.D., split type, cup design inj. temp. 250 °C detector TCD, 200 °C Analysis Note Th...

    GC Analysis of Water in Ethanol (0.05%Standard) on Watercol™ 1910

    column Watercol 1910, 30 m x 0.25 mm I.D., 0.20 µm (29711-U) oven 80 °C (10 min) carrier gas helium, 26 cm/sec sample water at 0.05% (v/v) in ethanol injection 0.5 µL, 100:1 split liner 4 mm I.D., split type, cup design inj. temp. 250 °C detector TCD, 200 °C Analysis Note The "Watercol" series of io...

    GC Analysis of Water (0.05-1%Calibration Curve) on Watercol™ 1460

    column Watercol 1460, 30 m x 0.25 mm I.D., 0.20 µm (29695-U, two identical columns installed in the same inlet, each going to a separate detector) oven 45 °C (4 min), 5 °C/min to 75 °C, 10 °C/min to 220 °C (10 min) carrier gas helium, 20 cm/sec (measured in each column at an oven temperature of 135 ...

    GC Analysis of Water in Ethanol (0.05%Standard) on Watercol™ 1900

    column Watercol 1900, 30 m x 0.25 mm I.D., 0.20 µm (29761-U) oven 80 °C (10 min) carrier gas helium, 26 cm/sec sample water at 0.05% (v/v) in ethanol injection 0.5 µL, 100:1 split liner 4 mm I.D., split type, cup design inj. temp. 250 °C detector TCD, 200 °C Analysis Note The "Watercol" series of io...

    GC Analysis of Parabens on SLB®-5ms after SPME using 50/30 μm DVB/Carboxen/PDMS Fiber

    sample/matrix parabens, each at 200 ppb in 3 mL water + 25% sodium chloride in a 4 mL vial desorption process 260 °C, 2 min extraction immersion with stirring, 25 °C (15 min) SPME fiber metal fiber assembly coated with 50/30 µm DVB/Carboxen/PDMS (57912-U) column SLB-5ms, 20 m x 0.18 mm I.D., 0.36 µm...

    GC Analysis of Water in Ethanol (0.05%Standard) on Watercol™ 1460

    column Watercol 1460, 30 m x 0.25 mm I.D., 0.20 µm (29695-U) oven 60 °C (12 min) carrier gas helium, 26 cm/sec sample water at 0.05% (v/v) in ethanol injection 0.5 µL, 100:1 split liner 4 mm I.D., split type, cup design inj. temp. 250 °C detector TCD, 200 °C Analysis Note The "Watercol" series of io...

    GC Analysis of Water in Ethanol (60%Standard) on Watercol™ 1460

    column Watercol 1460, 30 m x 0.25 mm I.D., 0.20 µm (29695-U) oven 60 °C (12 min) carrier gas helium, 26 cm/sec sample water at 80% (v/v) in ethanol injection 0.1 µL, 100:1 split liner 4 mm I.D., split type, cup design inj. temp. 250 °C detector TCD, 200 °C Analysis Note The "Watercol" series of ioni...

    GC Analysis of Water in Ethanol (60%Standard) on Watercol™ 1460

    column Watercol 1460, 30 m x 0.25 mm I.D., 0.20 µm (29695-U) oven 60 °C (12 min) carrier gas helium, 26 cm/sec sample water at 20% (v/v) in ethanol injection 0.5 µL, 100:1 split liner 4 mm I.D., split type, cup design inj. temp. 250 °C detector TCD, 200 °C Analysis Note The "Watercol" series of ioni...