    85 matches found for essential oils

    GC Analysis of Ravensara aromatica Essential Oil on SLB®-5ms

    column SLB-5ms, 30 m x 0.25 mm I.D., 0.25 µm (28471-U) oven 50 °C, 3 °C/min to 250 °C (5 min) carrier gas helium, 30 cm/sec, constant sample ravensara aromatica essential oil diluted 1:10 in n-hexane injection 1 µL, 50:1 split inj. temp. 280 °C detector FlD, 280 °C Analysis Note Ravensara aromatica,...

    GC Analysis of Native Spearmint Essential Oil on SUPELCOWAX® 10

    column SUPELCOWAX 10, 30 m x 0.25 mm I.D., 0.25 µm (24079) oven 75 °C (4 min), then 4 °C/min to 200 °C (10 min) carrier gas helium, 25cm/ sec set at 110C sample Native Spearmint Oil, (A.M. Todd Sample), neat injection 0.1 µL100:1 split liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID, 250...

    GC Analysis of Native Spearmint Essential Oil on Equity®-1

    column Equity-1, 30 m x 0.25 mm I.D., 0.25 µm (28046-U) oven 75 °C (8 min), then 4 °C/min to 200 °C (15 min) carrier gas helium, 25cm/ sec set at 110C sample Native Spearmint Oil, (A.M. Todd Sample), neat injection 0.1 µL, 100:1 split liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID, 250 ...

    GC Analysis of Geranium Bourbon Essential Oil on SUPELCOWAX® 10

    column SUPELCOWAX 10, 30 m x 0.25 mm I.D., 0.25 µm (24079) oven 50 °C (2 min), 2 °C/min to 230 °C (1 min) carrier gas helium, 20 cm/sec @ 155 °C sample neat oil injection 0.2 µL, 100:1 split detector FID Categories Analytical Chromatography, GC Applications, Essential Oils Featured Industry Flavors ...

    GC Analysis of Lavender Spike Essential Oil on SLB®-IL60

    column SLB-IL60, 30 m x 0.25 mm I.D., 0.20 µm (29505-U) oven 50 °C, 3 °C/min to 270 °C (5 min) carrier gas helium, 30 cm/s sample Lavender spike essential oil injection 0.5 µL50:1 split inj. temp. 270 °C detector FID, 270 °C Categories Analytical Chromatography, GC Applications, Essential Oils Featu...

    GC Analysis of Leptosperµm scoparium Essential Oil on SLB®-5ms

    column SLB-5ms, 30 m x 0.25 mm I.D., 0.25 µm (28471-U) oven 50 °C, 3 °C/min to 250 °C (5 min) carrier gas helium, 30 cm/sec, constant sample Leptospennum scoparium essential oil diluted 10:1 in n-hexane injection 1 µL, 50:1 split injection 280 °C detector FlD, 280 °C Analysis Note Leptosperµm scopar...

    GC Analysis of Kennewick Peppermint Essential Oil on SLB®-5ms

    column SLB-5ms, 30 m x 0.25 mm I.D., 0.25 µm (28471-U) oven 75 °C (8 min), then 4 °C/min to 200 °C (15 min) carrier gas helium, 25cm/ sec set at 110C sample Kennewick Peppermint Oil, (A.M. Todd Sample), neat liner 4 mm I.D. cup injector inj. temp. 250 °C detector 0.1 µL, 100:1 split detector FID, 25...

    GC Analysis of Scotch Spearmint Essential Oil on SLB®-IL60

    column SLB-IL60, 30 m x 0.25 mm I.D., 0.25 µm (29505-U) oven 75 C (4 min), then 4 °C/min to 200 °C (10 min) carrier gas helium, 25cm/ sec set at 110C sample Scotch Spearmint Oil, (A.M. Todd Sample), neat injection 0.1 µL100:1 split liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID, 250 °C ...

    GC Analysis of Willamette Peppermint Essential Oil on SLB®-IL60

    column SLB-IL60, 30 m x 0.25 mm I.D., 0.25 mm (29505-U) oven 75 °C (4 min), then 4 °C/min to 200 °C (10 min) carrier gas helium, 25cm/ sec set at 110C sample Willamette Peppermint Oil, (A.M. Todd Sample), neat injection 0.1 µL100:1 split liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID, 2...

    GC Analysis of Distilled Lime Essential Oil on SUPELCOWAX® 10

    column SUPELCOWAX 10, 30 m x 0.25 mm I.D., 0.25 µm (24079) oven 75 C (4 min), then 4 °C/min to 200 °C (10 min) carrier gas helium, 25cm/ sec set at 110C sample Distilled Lime Oil, Mexico, neat (W263109) injection 0.1 µL100:1 split liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID, 250 °C C...

    GC Analysis of Native Spearmint Essential Oil on SLB®-IL60

    column SLB-IL60, 30 m x 0.25 mm I.D., 0.25 µm (29505-U) oven 75 °C (4 min), then 4 °C/min to 200 °C (10 min) carrier gas helium, 25cm/ sec set at 110C sample Native Spearmint Oil, (A.M. Todd Sample), neat injection 0.1 µL100:1 split liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID, 250 °C...

    GC Analysis of Scotch Spearmint Essential Oil on SUPELCOWAX® 10

    column SUPELCOWAX 10, 30 m x 0.25 mm I.D., 0.25 µm (24079) oven 75 C (4 min), then 4 °C/min to 200 °C (10 min) carrier gas helium, 25cm/ sec set at 110C sample Scotch Spearmint Oil, (A.M. Todd Sample), neat injection 0.1 µL100:1 split liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID, 250 ...

    GC Analysis of Willamette Peppermint Essential Oil on SUPELCOWAX® 10

    column SUPELCOWAX 10, 30 m x 0.25 mm I.D., 0.25 µm (24079) oven 75 C (4 min), then 4 °C/min to 200 °C (10 min) carrier gas helium, 25cm/ sec set at 110C sample Willamette Peppermint Oil, (A.M. Todd Sample), neat injection 0.1 µL100:1 split liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID,...

    GC Analysis of Scotch Spearmint Essential Oil on SLB®-5ms

    column SLB-5ms, 30 m x 0.25 mm I.D., 0.25 mm (28471-U) oven 75 C (8 min), then 4 °C/min to 200 °C (15 min) carrier gas helium, 25cm/ sec set at 110C sample Scotch Spearmint Oil, (A.M. Todd Sample), neat injection 0.1 µL100:1 split liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID, 250 °C C...

    GC Analysis of Willamette Peppermint Essential Oil on SLB®-5ms

    column SLB-5ms, 30 m x 0.25 mm I.D., 0.25 µm (28471-U) oven 75 C (8 min), then 4 °C/min to 200 °C (15 min) carrier gas helium, 25cm/ sec set at 110C sample Willamette Peppermint Oil, (A.M. Todd Sample), neat injection 0.1 µL, 100:1 split liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID, 2...

    GC Analysis of Scotch Spearmint Essential Oil on Equity®-1

    column Equity-1, 30 m x 0.25 mm I.D., 0.25 µm (28046-U) oven 75 C (8 min), then 4 °C/min to 200 °C (15 min) carrier gas helium, 25cm/ sec set at 110C sample Scotch Spearmint Oil, (A.M. Todd Sample), neat injection 0.1 µL, 100:1 split liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID, 250 °...

    GC Analysis of D & L-Carvone Enantiomers in Dill Seed Essential Oil (Spiked with L-Carvone Enantiomer) on Astec® CHIRALDEX® G-TA

    column CHIRALDEX G-TA, 30 m x 0.25 mm I.D., 0.12 µm (73033AST) oven 40 °C (1 min), then 2 °C/min to 170 °C (15 min) carrier gas helium, 25cm/ sec set at 110C sample Dill Seed Oil + L- Carvone Spike, neat injection 0.1 µL100:1 split liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID, 250 °C ...

    GC Analysis of D & L-Carvone Enantiomers in Native Spearmint Essential Oil (Spiked with D-Carvone Enantiomer) on Astec® CHIRALDEX® G-TA

    column CHIRALDEX G-TA, 30 m x 0.25 mm I.D., 0.12 µm (73033AST) oven 40 °C (1 min), then 2 °C/min to 170 °C (15 min) carrier gas helium, 25cm/ sec set at 110C sample Native Spearmint Oil + D- Carvone Spike, neat injection 0.1 µL100:1 split liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID, ...

    GC Analysis of D & L-Carvone Enantiomers in Scotch Spearmint Essential Oil (Spiked with D-Carvone Enantiomer) on Astec® CHIRALDEX® G-TA

    column CHIRALDEX G-TA, 30 m x 0.25 mm I.D., 0.12 µm (73033AST) oven 40 °C (1 min), then 2 °C/min to 170 °C (15 min) carrier gas helium, 25cm/ sec set at 110C sample Scotch Spearmint Oil + D- Carvone Spike, neat injection 0.1 µL100:1 split liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID, ...

    GC Analysis of Terpenes in Cannabis on Equity®-1 after Headspace SPME using 50/30 μm DVB/CAR/PDMS Fiber

    sample preparation 30 min equilibration at 40 °C prior to extraction sample preparation fiber postbake after extraction, 3 min at 270 °C sample/matrix 0.5 g dried cannabis in 10 mL headspace vial desorption process 3 min, 270 °C extraction 20 min, headspace, 40 °C SPME fiber Divinylbenzene/Carboxen/...

    GC Analysis of Terpenes in Hops (Cascade Variety) on Equity®-1 after Headspace SPME using 50/30 μm DVB/CAR/PDMS Fiber

    sample preparation 30 min equilibration at 40 °C prior to extraction sample preparation fiber postbake after extraction, 3 min at 270 °C sample/matrix ground Cascade variety hop pellets desorption process 3 min, 270 °C extraction 20 min, headspace, 40 °C SPME fiber Divinylbenzene/Carboxen/Polydimeth...

    GC Analysis of Pesticide Residues in Hops on SLB®-5ms after QuEChERS Extraction then QuEChERS Cleanup using Supel™ QuE Verde

    sample preparation Solid Phase Extraction (Dispersive (QuEChERS)) sample preparation place supernatant in amber low adsorption vial for GC/MS/MS analysis. sample/matrix Ground hop pellets, 1 gm, spiked at 50 ng/g. extraction tube Supel QuE Citrate (EN) Tube (55227-U) extraction process Add 10 mL wat...

    GC Analysis of Terpenes in Hops (US Goldings) on Equity®-1 after Headspace SPME using 50/30 μm DVB/CAR/PDMS Fiber

    sample preparation 30 min equilibration at 40 °C prior to extraction sample preparation fiber postbake after extraction, 3 min at 270 °C sample/matrix ground US Golding hop pellets desorption process 3 min, 270 °C extraction 20 min, headspace, 40 °C SPME fiber Divinylbenzene/Carboxen/Polydimethylsil...

    GC Analysis of FAMEs in Walnuts on SLB®-IL111

    column SLB-IL111, 100 m x 0.25 mm I.D., 0.20 µm (29647-U) oven 168 °C carrier gas FID, 250 °C sample ground walnuts prepared for analysis per AOCS Official Method Ce 1k-09 injection 1 µL, split 100:1 liner 4 mm ID FocusLiner w/taper inj. temp. 250 °C detector FID, 250 °C Analysis Note This applicati...

    GC Analysis of FAMEs in Walnuts on SP™-2560

    column SP-2560, 100 m x 0.25 mm I.D., 0.20 µm (24056) oven 180 °C carrier gas helium, 1 mL/min sample ground walnuts prepared for analysis per AOCS Official Method Ce 1k-09 injection 1 µL, split 100:1 liner 4 mm ID FocusLiner w/taper inj. temp. 250 °C detector FID, 250 °C Analysis Note This applicat...