• Home
  • Search Results

  • fragrance

EMAIL THIS PAGE TO A FRIEND

Product Category
Materials Science(180)

view products:

Compare products:

Select the checkbox on up to 4 items, then click 'compare' for a detailed product comparison

*Please select more than one item to compare

    Search term:"fragrance"

    202 matches found for fragrance

    GC Analysis of Potpourri Fragrance Compounds on SUPELCOWAX® 10

    column SUPELCOWAX 10, 30 m x 0.25 mm I.D., 0.25 µm (24079) oven 50 °C (0 min), then 8 °C/min to 270 °C (35 min) carrier gas helium, 25cm/ sec set at 110C sample Mixture of Potpourri Fragrance Compounds, neat injection 0.1 µL100:1 split liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID, 280...

    GC Analysis of Fragrance Compounds in Shampoo Base on a 100% Methyl Column after SPME using 100 μm PDMS Fiber

    desorption process 5 min, 250 °C desorption temp. -50 °C w/liquid CO2 extraction headspace, 5 min, 80 °C (with sample stirring) SPME fiber polydimethylsiloxane, 100 µm film (57300-U) column 100% methyl polysiloxane, 50 m x 0.25 mm I.D., 0.25 µm (Supelco equivalent, Equity-1, 28047-U) oven 35 °C to 2...

    GC Analysis of Potpourri Fragrance Compounds on SLB®-IL60

    column SLB-IL60, 30 m x 0.25 mm I.D., 0.25 µm (29505-U) oven 50 °C (0 min), then 8 °C/min to 270 °C (20 min) carrier gas helium, 25cm/ sec set at 110C sample Mixture of Potpourri Fragrance Compounds, neat injection 0.1 µL (100:1 split) liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID, 280...

    GC Analysis of Potpourri Fragrance Compounds on SLB®-5ms

    column SLB-5ms, 30 m x 0.25 mm I.D., 0.25 µm (28471-U) oven 50 °C (0 min), then 8 °C/min to 200 °C (1 min) then 20 °C/min to 300 °C (20 min) carrier gas helium, 25cm/ sec set at 110C sample Mixture of Potpourri Fragrance Compounds, neat injection 0.1 µL100:1 split liner 4 mm I.D. cup injector inj. t...

    GC Analysis of Potpourri Fragrance Compounds on Equity®-1

    column Equity-1, 30 m x 0.25 mm I.D., 0.25 µm (28046-U) oven 50 °C (0 min), then 8 °C/min to 200 °C (1 min) then 20 °C/min to 300 °C (20 min) carrier gas helium, 25cm/ sec set at 110C sample Mixture of Potpourri Fragrance Compounds, neat injection 0.1 µL, 100:1 split liner 4 mm I.D. cup injector inj...

    GC Analysis of Sicilian Mandarin Essential Oil on SLB®-5ms

    column SLB-5ms, 30 m x 0.25 mm I.D., 0.25 µm (28471-U) oven 50 °C, 3 °C/min. to 250 °C (10 min), 10 °C/min to 270 °C (3 min) carrier gas helium, 30 cm/sec, constant sample Sicilian mandarin essential oil diluted 1:10 in n-hexane injection 1 µL, 50:1 split inj. temp. 280 °C detector FID, 280 °C Analy...

    HPLC Analysis of 4-Methyimidazole (4-MeI) in Cola Beverage on SeQuant ZIC-HILIC

    column SeQuant ZIC-HILIC, PEEK, 150 x 4.6 mm, 5 µm, 200 Ã… (1.50455.0001) column temp. 40 °Cambient mobile phase [A] ammonium formate; [B] acetonitrile; (90:10, A,B) flow rate 2.0 mL/min sample 25 ppm 4-methylimidazole injection 50 µL detector 230 nm Categories Analytical Chromatography, Flavors, Fr...

    GC Analysis of Cold Pressed Lemon Essential Oil on SLB®-IL60

    column SLB-IL60, 30 m x 0.25 mm I.D., 0.25 µm (29505-U) oven 75 C (4 min), then 4 °C/min to 200 °C (10 min) carrier gas helium, 25cm/ sec set at 110C sample Cold Pressed Lemon Oil, (Sigma), neat injection 0.1 µL100:1 split liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID, 250 °C Categorie...

    GC Analysis of Patchouli Essential Oil on SUPELCOWAX® 10

    column SUPELCOWAX 10, 30 m x 0.25 mm I.D., 0.25 µm (24079) oven 50 °C (0 min), then 5 °C/min to 250 °C (10 min) carrier gas helium, 25cm/ sec set at 110C sample Patchouli Oil, neat (W283800) injection 0.1 µL100:1 split liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID, 250 °C Categories An...

    GC Analysis of Cold Pressed Lemon Essential Oil on SUPELCOWAX® 10

    column SUPELCOWAX 10, 30 m x 0.25 mm I.D., 0.25 µm (24079) oven 75 °C (4 min), then 4 °C/min to 200 °C (10 min) carrier gas helium, 25cm/ sec set at 110C sample Cold Pressed Lemon Oil, (Sigma), neat injection 0.1 µL100:1 split liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID, 250 °C Categ...

    GC Analysis of α-Pinene Enantiomers on Astec® CHIRALDEX® B-DM

    column Astec CHIRALDEX B-DM, 30 m x 0.25 mm I.D., 0.12 µm (77023AST) oven 50 °C carrier gas helium, 30 psi sample 4 mg/mL in methylene chloridepeak 1: l-alpha-pinene (S(-)-alpha-pinene)peak 2: d-alpha-pinene (R(+)-alpha-pinene) injection 1 µL, 80:1 split inj. temp. 250 °C detector FID, 250 °C Analys...

    GC Analysis of Patchouli Essential Oil on SLB®-IL60

    column SLB-IL60, 30 m x 0.25 mm I.D., 0.25 µm (29505-U) oven 50 °C (0 min), then 5 °C/min to 250 °C (10 min) carrier gas helium, 25cm/ sec set at 110C sample Patchouli Oil, neat (W283800) injection 0.1 µL100:1 split liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID, 250 °C Categories Analy...

    GC Analysis of Cold-Pressed Mandarin Essential Oil on SLB®-5ms

    column SLB-5ms, 30 m x 0.25 mm I.D., 0.25 µm (28471-U) oven 50C at 3C/min to 250C, held 10 min, at 10C/min to 270C, held 3 min carrier gas He at 30.1 cm/s and pressure of 99.8 kPa detector FID, 280 °C Categories Analytical Chromatography, GC Applications, Essential Oils Featured Industry Flavors and...

    GC Analysis of β-Pinene Enantiomers on Astec® CHIRALDEX® B-DM

    column Astec CHIRALDEX B-DM, 30 m x 0.25 mm I.D., 0.12 µm (77023AST) oven 70 °C carrier gas helium, 30 psi sample 5 mg/mL in ethanolpeak 1: d-beta-pinenepeak 2: l-beta-pinene injection 0.2 µL, 80:1 split inj. temp. 250 °C detector FID, 250 °C Analysis Note Elution order reversal on CHIRALDEX G-DP. C...

    HPLC Analysis of Isoflavones on Ascentis® Phenyl

    column Ascentis Phenyl, 15 cm x 4.6 mm I.D., 5 µm particles (581616-U) column temp. 35 °C mobile phase [A] 10 mM ammonium formate (pH 3.0 with concentrated formic acid), [B] methanol flow rate 1 mL/minsplit to the MS sample glycitein, genistein at 1 µg/mL, equol at 50 µg/mL and daidzin, glycitin, ge...

    GC Analysis of cis/trans Limonene Oxide Enantiomers on Astec® CHIRALDEX® B-PH

    column Astec CHIRALDEX B-PH, 30 m x 0.25 mm I.D., 0.12 µm (71023AST) oven 90 °C carrier gas helium, 24 psi sample 3 mg/mL in methylene chloridepeak 1: d-cis or d-trans limonene oxidepeak 2: l-cis and trans limonene oxidepeak 3: d-trans or d-cis limonene oxide injection 1 µL, 80:1 split inj. temp. 25...

    GC Analysis of Distilled Lime Essential Oil on Equity®-1 and Equity®-5

    column Equity-5, 30 m x 0.25 mm I.D., 0.25 µm (28089-U) column Equity-1, 30 m x 0.25 mm I.D., 0.25 µm (28046-U) oven 75 °C (8 min), 4 °C/min to 200 °C (10 min) carrier gas helium, 30 cm/sec @ 110 °C sample distilled lime oil injection Wet Needle, 100:1 split liner split, cup design inj. temp. 250 °C...

    GC Analysis of D & L-Carvone Enantiomers in Caraway Essential Oil (Spiked with L-Carvone Enantiomer) on Astec® CHIRALDEX® G-TA

    column CHIRALDEX G-TA, 30 m x 0.25 mm I.D., 0.12 µm (73033AST) oven 40 °C (1 min), then 2 °C/min to 170 °C (15 min) carrier gas helium, 25cm/ sec set at 110C sample Dill Seed Oil + L- Carvone Spike, neat injection 0.1 µL100:1 split liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID, 250 °C ...

    GC Analysis of Lavender Flower Essential Oil on SUPELCOWAX® 10

    column SUPELCOWAX 10, 30 m x 0.25 mm I.D., 0.25 µm (24079) oven 50 °C, 3 °C/min to 280 °C (5 min) carrier gas helium, 30 cm/s sample Lavender flower essential oil injection 0.5 µL20:1 split inj. temp. 280 °C detector MSD Categories Analytical Chromatography, GC Applications, Essential Oils Featured ...

    GC Analysis of Distilled Lime Essential Oil on Equity®-1 (15 m x 0.10 mm I.D., 0.10 μm), Fast GC Analysis

    column Equity-1, 15 m x 0.10 mm I.D., 0.10 µm (28039-U) oven 75 °C (1 min), 35 °C/min to 200 °C (1 min) carrier gas helium, 45 cm/sec constant sample distilled lime oil, neat injection 0.10 µL, 300:1 split liner 2 mm I.D., straight inj. temp. 250 °C detector FID, 250 °C Categories Analytical Chromat...

    GC Analysis of Verbenone Enantiomers on Astec® CHIRALDEX® G-TA

    column Astec CHIRALDEX G-TA, 30 m x 0.25 mm I.D., 0.12 µm (73033AST) oven 120 °C carrier gas helium, 30 psi sample 2.5 mg/mLpeak 1: R(+)-verbenonepeak 2: S(-)-verbenone injection 1 µL, 80:1 split inj. temp. 250 °C detector FID, 250 °C Analysis Note Can reverse elution order by using CHIRALDEX B-TA. ...

    GC Analysis of Kennewick Peppermint Essential Oil on SLB®-IL60

    column SLB-IL60, 30 m x 0.25 mm I.D., 0.25 µm (29505-U) oven 75 C (4 min), then 4 °C/min to 200 °C (10 min) carrier gas helium, 25cm/ sec set at 110C sample Kennewick Peppermint Oil, (A.M. Todd Sample), neat injection 0.1 µL100:1 split liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID, 250...

    GC Analysis of D & L-Carvone Enantiomers in Dill Seed Essential Oil (Spiked with L-Carvone Enantiomer) on Astec® CHIRALDEX® G-TA

    column CHIRALDEX G-TA, 30 m x 0.25 mm I.D., 0.12 µm (73033AST) oven 40 °C (1 min), then 2 °C/min to 170 °C (15 min) carrier gas helium, 25cm/ sec set at 110C sample Dill Seed Oil + L- Carvone Spike, neat injection 0.1 µL100:1 split liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID, 250 °C ...

    GC Analysis of Lavender Flower Essential Oil on SLB®-IL60

    column SLB-IL60, 30 m x 0.25 mm I.D., 0.20 µm (29505-U) oven 50 °C, 3 °C/min to 270 °C (5 min) carrier gas helium, 30 cm/s sample Lavender flower essential oil injection 0.5 µL50:1 split inj. temp. 270 °C detector FID, 270 °C Categories Analytical Chromatography, GC Applications, Essential Oils Feat...

    GC Analysis of Camphor Enantiomers on Astec® CHIRALDEX® G-DP

    column Astec CHIRALDEX G-DP, 30 m x 0.25 mm I.D., 0.12 µm (78033AST) oven 100 °C carrier gas helium, 30 psi sample peaks 1 & 2: camphor enantiomers inj. temp. 250 °C detector FID, 250 °C Categories Analytical Chromatography, GC Applications, Enantiomers, Volatiles Featured Industry Chemicals and Ind...

    HPLC Analysis of an Energy Drink on Ascentis® Express HILIC (ELSD Detection)

    column Ascentis Express HILIC, 5 cm x 3 mm I.D., 2.7 µm particles (53967-U) column temp. 35 °C mobile phase [A] 100 mM ammonium acetate, pH 5 (titrated with acetic acid) [B] water [C] acetonitrile; (9:1:90, A:B:C:) flow rate 0.6 mL/min sample Energy Drink Diluted 1:9 in acetonitrile injection 2 µL d...

    GC Analysis of Distilled Lime Essential Oil on Equity®-1

    column Equity-1, 30 m x 0.25 mm I.D., 0.25 µm (28046-U) oven 75 C (4 min), then 4 °C/min to 200 °C (5 min) carrier gas helium, 25cm/ sec set at 110C sample Distilled Lime Oil, Mexico, neat (W263109) injection 0.1 µL, 100:1 split liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID, 250 °C Cat...

    HPLC Analysis of Flavonoids in Orange Juice on Ascentis® C18

    column Ascentis C18, 25 cm x 4.6 mm I.D., 5 µm particles (581325-U) column temp. 25 °C mobile phase [A] formic acid: [B] 2-propanol: [C] acetonitrile: [D] water (0.1:10:12:78, A:B:C:D:) flow rate 0.8 mL/min sample orange juice, passed through a 0.45 µm filter injection 10 µL detector PDA, 283 nm Cat...

    GC Analysis of Verbenone Enantiomers on Astec® CHIRALDEX® B-TA

    column Astec CHIRALDEX B-TA, 30 m x 0.25 mm I.D., 0.12 µm (73023AST) oven 120 °C carrier gas helium, 30 psi sample 2.5 mg/mLpeak 1: S(-)-verbenonepeak 2: R(+)-verbenone injection 1 µL, 80:1 split inj. temp. 250 °C detector FID, 250 °C Analysis Note Can reverse elution order by using CHIRALDEX G-TA. ...

    GC Analysis of D & L-Carvone Enantiomers in Native Spearmint Essential Oil (Spiked with D-Carvone Enantiomer) on Astec® CHIRALDEX® G-TA

    column CHIRALDEX G-TA, 30 m x 0.25 mm I.D., 0.12 µm (73033AST) oven 40 °C (1 min), then 2 °C/min to 170 °C (15 min) carrier gas helium, 25cm/ sec set at 110C sample Native Spearmint Oil + D- Carvone Spike, neat injection 0.1 µL100:1 split liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID, ...