Milligard® PES 1.2/0.2 μm nominal, Opticap® T-line 30 capsule

inlet and outlet for 1.5 in. (Sanitary Flange ), sterilization compatible with autoclavable

Sign In to View Organizational & Contract Pricing.

Select a Size

Pricing and availability is not currently available.

About This Item

UNSPSC Code:
23151806

Skip To

Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist

Product Name

Milligard® PES 1.2/0.2 μm nominal, Opticap® T-line 30 capsule, inlet and outlet for 1.5 in. (Sanitary Flange ), sterilization compatible with autoclavable

material

polyester support
polyethersulfone membrane (Hydrophilic (PES))
polypropylene housing (Gamma Stable)
silicone O-ring

sterilization compatibility

autoclavable compatible
gamma compatible

product line

Opticap®

feature

hydrophilic

technique(s)

prefiltration: suitable

L × W

83.9 cm (32.6 in.) × 8.9 cm (3.5 in.)

filtration area

1.8 m2 (19.4 ft2)

matrix

Milligard® PES

pore size

1.2/0.2 μm pore size (nominal)

fitting

inlet and outlet for 1.5 in. (Sanitary Flange )

Quality Level

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
KMP2G3TTT1KMP2G3STH1KMP2G2STT1
pore size

1.2/0.2 μm pore size (nominal)

pore size

1.2/0.2 μm pore size (nominal)

pore size

1.2/0.2 μm pore size (nominal)

pore size

1.2/0.2 μm pore size (nominal)

filtration area

1.8 m2 (19.4 ft2)

filtration area

1.8 m2 (19.4 ft2)

filtration area

1.8 m2 (19.4 ft2)

filtration area

1.2 m2 (12.8 ft2)

product line

Opticap®

product line

Opticap®

product line

Opticap®

product line

Opticap®

technique(s)

prefiltration: suitable

technique(s)

prefiltration: suitable

technique(s)

prefiltration: suitable

technique(s)

prefiltration: suitable

material

polyester support, polypropylene housing (Gamma Stable), polyethersulfone membrane (Hydrophilic (PES)), silicone O-ring

material

polyester support, polyethersulfone membrane (Hydrophilic (PES)), polypropylene housing (Gamma Stable), silicone O-ring

material

polyester support, polyethersulfone membrane (Hydrophilic (PES)), polypropylene housing (Gamma Stable), silicone O-ring

material

polyester support, polyethersulfone membrane (Hydrophilic (PES)), polypropylene housing (Gamma Stable), silicone O-ring

matrix

Milligard® PES

matrix

Milligard® PES

matrix

Milligard® PES

matrix

Milligard® PES

Application

Prefiltration and bioburden control

Disclaimer

Filters are designed, developed and manufactured in accordance with a Quality Management System approved by an accredited registering body to the ISO 9001 Quality Systems Standard. Certificate of Quality is available online for all filters.

Features and Benefits

Fast flow and high throughputValidated bioburden reductionPredictable scalability from small-scale to production-size devices High thermal stability: compatible with steam-in-place and autoclave sterilization methods Single-use, gamma-ready formatsCaustic stable

General description

Milligard® PES 1.2/0.2 μm nominal filters are designed for effective bioburden control and reliable particulate removal from a broad range of fluid streams. When used standalone for non critical applications, these membrane-based filters typically remove Ͱ 6 log Brevundimonas diminuta. When used upstream of sterilizing-grade filters or other unit operations, they improve processing efficiency.
Milligard® PES filters are supported by the Emprove® Program which consolidates product specific testing, quality and regulatory information to simplify compliance needs.

Other Notes

Directions for Use


Organism Retention: Microorganism
Mode of Action: Filtration (size exclusion)
Application: BioProcessing
Intended Use: Reduction or removal of microorganism/bioburden
Instructions for Use: Please refer to Opticap® Small Scale 300 Capsule, XL, XLT and T-line Capsules User Guide
Storage Statement: Store in dry location
Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

Packaging

PE Bag

Legal Information

Emprove is a registered trademark of Merck KGaA, Darmstadt, Germany
MILLIGARD is a registered trademark of Merck KGaA, Darmstadt, Germany
OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany

Stay compliant with GMP using the Emprove® Program

Accelerate qualification, maintain compliance, and save time with Emprove® Dossiers.

Download Dossiers

Note: you will be brought to EmproveSuite.com. Your username and password are separate from SigmaAldrich.com and may differ.

Register for free and access Emprove® Dossiers within minutes. Upgrade your subscription plan to unlock advanced and customized content in the Emprove® Suite

Not finding what you are looking for? Visit the Emprove® Program Help page.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Questions

Reviews

No rating value

Active Filters

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service