Quality Segment
material
316L stainless steel cannula, polyester body, polyethylene bag (drainage bag (PureFlex Film)), polypropylene tube (Fluid contact layer), polystyrene device, silicone septum (Platinum-cured), silicone tube (Fluid contact layer: platinum-cured silicone), silicone tube (medical silicone fluid), silicone tubing
agency
according to ISO (sterilization), meets ISO 14644-1, meets USP 88 Biological Reactivity (all component materials)
sterility
sterile; γ-irradiated
product line
NovaSeptum® GO
feature
autoclavable: no
parameter
0.50 bar max. pressure (7.25 psi), 2-60 °C temp. range (36-140 °F)
fitting
female Luer-Lok® outlet fitting, male Luer-Lok® outlet fitting
application(s)
cell therapy
gene therapy
life science and biopharma
mAb
ophthalmics
parenterals
pharma/biopharma processes
sterile sampling
viral therapy
storage temp.
room temp
General description
This is a multi-sampling (manifold) device
Application
- Multi Sampling (Manifold)
- Sterile Sampling
Features and Benefits
- Fluid contact layer made of polystyrene, ideal for endotoxin testing
- Small size, no need to aliquot
- Manifold format
Packaging
Other Notes
- Septum: Platinum-cured silicone
- Body: Polyester
- Cannula: ASTM® 316 L Stainless steel
- Drainage bag: Polyethylene film (PureFlex film)
- Fluid contact layer (tube): Polypropylene, platinum-cured silicone, medical silicone fluid
- Tubing: Silicone
- Outlet Tubing: Female and male Luer-Lok®
Legal Information
1 of 1
Este artículo | |||
|---|---|---|---|
| description sterile; γ-irradiated | description sterile; γ-irradiated, volume × volume 15 mL × 50 mL | description sterile; γ-irradiated, volume × volume 15 mL × 50 mL | description sterile; γ-irradiated |
| fitting male Luer-Lok® outlet fitting, female Luer-Lok® outlet fitting | fitting - | fitting - | fitting female Luer-Lok® outlet fitting, male Luer-Lok® outlet fitting |
| product line NovaSeptum® GO | product line NovaSeptum® GO | product line NovaSeptum® GO | product line NovaSeptum® GO |
| agency meets USP 88 Biological Reactivity (all component materials), meets ISO 14644-1, according to ISO (sterilization) | agency according to ISO Clean Room Class 8 conditions in a facility, according to ISO 11137 (sterilization), meets USP 88 biological reactivity (all component materials), certified by the ISO 14644-1 standards | agency certified by the ISO 14644-1 standards, according to ISO 11137 (sterilization), according to ISO Clean Room Class 8 conditions in a facility, meets USP 88 biological reactivity (all component materials) | agency meets USP 88 Biological Reactivity (all component materials), meets ISO 14644-1, according to ISO (sterilization) |
| material polypropylene tube (Fluid contact layer), polystyrene device, silicone tubing, silicone tube (medical silicone fluid), polyester body, silicone septum (Platinum-cured), polyethylene bag (drainage bag (PureFlex Film)), silicone tube (Fluid contact layer: platinum-cured silicone), 316L stainless steel cannula | material TPE tubing (Inlet C-Flex), polycarbonate Luer lock, polypropylene clip (TTP clip), polystyrene tube (Fluid contact layer (conical tube)), tubing (Female and male Luer-Lok®), polypropylene tube (Fluid contact layer (conical tube)) | material silicone septum ( Platinum-cured), polypropylene tube (Fluid contact layer (conical tube)), polyester body, 316 stainless steel cannula (ASTM®), polystyrene tube (Fluid contact layer (conical tube)), polypropylene clip (TTP clip), tubing (Female and male Luer-Lok®) | material polystyrene device, polypropylene tube (Fluid contact layer), polyester body, silicone tubing, silicone septum (Platinum-cured), silicone tube (Fluid contact layer: platinum-cured silicone), silicone tube (medical silicone fluid), 316L stainless steel cannula |
| sterility sterile; γ-irradiated | sterility sterile; γ-irradiated | sterility sterile; γ-irradiated | sterility sterile; γ-irradiated |
| parameter 2-60 °C temp. range (36-140 °F), 0.50 bar max. pressure (7.25 psi) | parameter max. pressure at 0.50 bar (7.25 psi), 2-60 °C temp. range (36-140 °F) | parameter 2-50 °C temp. range (36-112 °F), max. pressure at 0.50 bar (7.25 psi) | parameter 0.50 bar max. pressure (7.25 psi), 2-60 °C temp. range (36-140 °F) |
Cumpla las GMP con el programa Emprove®.
Acelere la cualificación, mantenga la conformidad y ahorre tiempo con Emprove® Dossiers.
Nota: será redirigido a EmproveSuite.com. Su nombre de usuario y contraseña son independientes de SigmaAldrich.com y pueden diferir.
Regístrese gratis y acceda a Emprove® Dossiers en cuestión de minutos. Actualice su plan de suscripción para desbloquear contenidos avanzados y personalizados en la Emprove® Suite
¿No encuentra lo que busca? Visite la página de ayuda del programa Emprove®..
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
¿Le resulta difícil encontrar su producto o lote/número de lote?
Cómo encontrar el número de producto
Las referencias de los producto se combinan con los tamaños de envase y las cantidades cuando se muestran en la página web, por ejemplo: T1503-25G. Asegúrese de introducir el número de producto ÚNICAMENTE en el campo del Número de producto (ejemplo: T1503).
Ejemplo:
Otros ejemplos
705578-5MG-PW
PL860-CGA/SHF-1EA
MMYOMAG-74K-13
1000309185
introducir como 1.000309185)
¿Tienes problemas? Siéntase libre de contactar Servicio técnico para asistencia