Skip To
material
cellulose matrix
glass support
Quality Level
feature
binder Organic Polymer
fluorescent indicator: no
packaging
pkg of 25 plates
technique(s)
thin layer chromatography (TLC): suitable
layer thickness
80-120 μm
plate L × W
20 cm × 20 cm
storage temp.
2-30°C
Related Categories
1 of 4
This Item | 1.05552 | 1.05577 | 1.05632 |
|---|---|---|---|
| material cellulose matrix, glass support | material aluminum support, cellulose matrix | material cellulose matrix, plastic support | material cellulose matrix, glass support |
| technique(s) thin layer chromatography (TLC): suitable | technique(s) thin layer chromatography (TLC): suitable | technique(s) thin layer chromatography (TLC): suitable | technique(s) thin layer chromatography (TLC): suitable |
| feature binder Organic Polymer, fluorescent indicator: no | feature binder Organic Polymer, fluorescent indicator: no | feature binder Organic Polymer, fluorescent indicator: no | feature binder Organic Polymer, fluorescent indicator: no |
| packaging pkg of 25 plates | packaging pkg of 25 sheets | packaging pkg of 25 sheets | packaging pkg of 100 plates |
| layer thickness 80-120 μm | layer thickness 70-110 μm | layer thickness 70-110 μm | layer thickness 80-120 μm |
| plate L × W 20 cm × 20 cm | plate L × W - | plate L × W - | plate L × W 10 cm × 10 cm |
General description
Application
- Rapid and sensitive naked eye detection of faecal pigments using their enhanced solid-state green fluorescence on a zinc acetate substrate.: This study highlights a rapid and sensitive method for detecting fecal pigments using cellulose TLC plates and zinc acetate substrate, which enhances green fluorescence visible to the naked eye (Prakash and Mishra, 2022).
- Long-Term Fluorescence Behavior of CdSe/ZnS Quantum Dots on Various Planar Chromatographic Stationary Phases.: This research investigates the fluorescence behavior of quantum dots on cellulose TLC plates, providing insights into their long-term stability and potential analytical applications (Zarzycki, 2022).
- Investigation of Hybrid Methods for Elimination of Brilliant Blue Dye from Water Phase Using Various Nanomaterials Combined with Activated Sludge and Duckweed.: This article explores the use of nanomaterials, including cellulose TLC plates, for the effective removal of dyes from water, demonstrating their utility in environmental chemistry (Zarzycki et al., 2021).
- Low-Temperature Plasma Probe Mass Spectrometry for Analytes Separated on Thin-Layer Chromatography Plates: Direct vs Laser Assisted Desorption.: This research compares direct and laser-assisted desorption methods for analytes separated on cellulose TLC plates, highlighting advancements in mass spectrometry techniques (Gong et al., 2020).
Analysis Note
Deviation of layer thickness per plate: ≤ 30 µm
Aminoacid test
hRf-values
- L-serine, amino acid test:
20 - 30
- L-threonine, amino acid test: 29 - 36
- L-alanine, amino acid test: 30 - 40
- L-methionine, amino acid test: 49 - 60
- L-phenylalanine, amino acid test: 59 - 70
- L-leucine, amino acid test: 66 - 76
Typical value determined on a plate
Eluent: 1-Butanol/ acetone/ acetic acid/ water (35/35/7/23 v/v/v/v) twice developed
Other Notes
related product
Storage Class Code
10-13 - German Storage Class 10 to 13
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Related Content
TLC Cellulose 20x10cm
TLC Cellulose
Active Filters
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service