Skip to Content
Merck

1.88010

Aquastar® Titrant 5

two component titrant for volumetric Karl Fischer titration, 1 ml ≙ ca. 5 mg H₂O Aquastar®


Sign In to View Organizational & Contract Pricing

Select a Size

Pricing and availability is not currently available.

About This Item

UNSPSC Code:
41115601
NACRES:
NA.21

Skip To

Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist

Product Name

Titrant 5, titrant for volumetric Karl Fischer titration with two component reagents 1 ml ≙ ca. 5 mg H2O Aquastar®

Quality Level

product line

Aquastar®

form

liquid

reaction suitability

reaction type: volumetric

concentration

5 mg/mL

technique(s)

Karl-Fischer titration: suitable
titration: suitable

transition temp

flash point <21 °C

density

0.85 g/cm3 at 20 °C

format

two component solution

storage temp.

15-25°C

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
1.880111.0130711855476001
reaction suitability

reaction type: volumetric

reaction suitability

reaction type: volumetric

reaction suitability

-

reaction suitability

-

technique(s)

Karl-Fischer titration: suitable

technique(s)

Karl-Fischer titration: suitable

technique(s)

-

technique(s)

RT-PCR: suitable

format

two component solution

format

two component solution

format

-

format

-

product line

Aquastar®

product line

Aquastar®

product line

-

product line

-

form

liquid

form

liquid

form

solid

form

-

concentration

5 mg/mL

concentration

2 mg/mL

concentration

-

concentration

-

Application

Titrant 5 is a two-component reagent that can be used to determine the water content in polymer gel films through Karl Fischer titration.[1]

Packaging

SKU-pack size numbers ending with a "3" are SmartChemicals with an RFID tag on the label for seamless data transfer to the instrument, e.g. xxxxxx1003 or xxxxxxx 4003. More information on www.sigmaaldrich.com/SmartChemicals

Analysis Note

Efficiency: ≥ 5.0

Other Notes

SKU-pack size numbers ending with a "3" are SmartChemicals with an RFID tag on the label for seamless data transfer to the instrument, e.g. xxxxxx1003 or xxxxxxx 4003. More information on www.sigmaaldrich.com/SmartChemicals

Legal Information

AQUASTAR is a registered trademark of Merck KGaA, Darmstadt, Germany

related product

Product No.
Description
Pricing

Signal Word

Danger

Hazard Classifications

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT RE 2 Oral - STOT SE 1

Target Organs

Thyroid

Storage Class Code

3 - Flammable liquids

WGK

WGK 2

Flash Point(F)

49.5 °F - (Methanol)

Flash Point(C)

9.7 °C - (Methanol)


Regulatory Listings

Regulatory Listings are mainly provided for chemical products. Only limited information can be provided here for non-chemical products. No entry means none of the components are listed. It is the user’s obligation to ensure the safe and legal use of the product.

EU REACH Annex XVII (Restriction List)

CAS No.

Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Articles

Methods including internal extraction, external extraction, and Karl Fischer oven ensure accurate water content determination by titration.

SmartChemicals enable wireless CoA data transfer, reducing human error in titration experiments.

Protocols

Accurately measure the moisture content in ethanolamine (HOCHCHNH) through Karl Fischer titration, using both volumetric or coulometric methods.

Summary application report for analysis of moisture in Perchloric acid 0.1 mol/L in acetic acid

Summary application report for analysis of moisture in Acids, aqueous

Summary application report for analysis of moisture in 1,2-Propanediol, propylene glycol

See All

Related Content

Die Karl-Fischer-Titration bestimmt den Wassergehalt in Rohstoffen und Produkten und ist eine weit verbreitete Analysemethode.

Karl Fischer titration determines water content in raw materials and products, a widely used analytical method.

Questions

1–3 of 3 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  3. Is the titrant 5 1.88010 for Karl Fischer contains both the titrant and solvent needed for Karl Fischer as it shows in picture.

    1 answer
    1. Product 1880101045 only has the Titrant 5.

      Helpful?

Reviews

No rating value

Active Filters

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service