The recommendation to use tissue culture grade water is primarily to ensure there are no trace elements or contaminants present that could impact the metabolic health of the cells being screened. The incubation period is relatively brief and cells are not likely to be negatively impacted. The use of sterile filtered or autoclaved water will not negatively impact the functionality of the kit. It would be up to the end user to deviate from the recommended protocol.
Select a Size
CHF 1’150.00
CHF 1’150.00
About This Item
Skip To
form
liquid
packaging
pkg of 1 kit
storage condition
dry at room temperature
technique(s)
protein quantification: suitable
λmax
490 nm
application(s)
cell analysis
detection
detection method
colorimetric
storage temp.
−20°C
Quality Level
usage
kit sufficient for 500 tests
1 of 4
This Item | TOX8 | TOX4 | TOX1 |
|---|---|---|---|
| technique(s) protein quantification: suitable | technique(s) protein quantification: suitable | technique(s) - | technique(s) - |
| form liquid | form liquid | form liquid | form - |
| usage kit sufficient for 500 tests | usage 1 kit sufficient for 2,000 tests | usage 1 kit sufficient for 1,000 tests | usage 1 kit sufficient for 1,000 tests |
| packaging pkg of 1 kit | packaging pkg of 1 kit | packaging pkg of 1 kit | packaging pkg of 1 kit |
| storage condition dry at room temperature | storage condition dry at room temperature | storage condition dry at room temperature | storage condition dry at room temperature |
| λmax 490 nm | λmax - | λmax 540 nm | λmax 570 nm |
Application
- to detect lactate dehydrogenase release in human umbilical vein endothelial cells (HUVECs) and human cardiac myocytes (HCMs) for lactate dehydrogenase (LDH) assay[1]
- to determine the activity of lactate dehydrogenase leakage of MDA-MB-231 cells[2]
- to examine the activity of LDH in RAW 264.7 cells [3], in LDH cytotoxicity assay in human cell lines[4]
- for spectrophotometric measurement of viable cells. Absorbance of converted dye is measured at a wavelength of 490 nm.
Biochem/physiol Actions
.
General description
hcodes
pcodes
Hazard Classifications
Aquatic Chronic 3
Storage Class
10 - Combustible liquids
Choose from one of the most recent versions:
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Articles
Saggi basati su cellule per la proliferazione cellulare (BrdU, MTT, WST1), la vitalità cellulare e gli esperimenti di citotossicità per applicazioni nella ricerca sul cancro, sulle neuroscienze e sulle cellule staminali.
Zellbasierte Assays für Zellproliferation (BrdU, MTT, WST1), Zelllebensfähigkeit und Zytotoxizitätsexperimente für Anwendungen in der Krebs-, Neurowissenschaft und Stammzellforschung.
Tests sur cellules pour l'étude de la prolifération (BrdU, MTT, WST1), de la viabilité et de la toxicité cellulaires pour la recherche sur le cancer, la recherche en neurosciences et la recherche sur cellules souches.
Cell based assays for cell proliferation (BrdU, MTT, WST1), cell viability and cytotoxicity experiments for applications in cancer, neuroscience and stem cell research.
Related Content
-
in the TOX7, it describes that the 25 ml of 1× LDH Assay Cofactor Preparation by adding 25 ml of tissue culture grade water to the bottle of lyophilized cofactors (Catalog Number L2527). Can I use Sterile Filtered and Autoclaved Sterile water to prepare?
1 answer-
Helpful?
-
-
How do i estimate the LDH release? what is the equation?
1 answer-
The TOX7 kit is utilized primarily as a cell viability assay based upon cellular metabolic activity. LDH reduces NAD+ which is then converted to a tetrazolium dye. This dye is then solubilized and read at 490nm. The resulting absorbance in associated with cell density or viability.
Please refer to the Product Information Sheet for more information regarding this product: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/336/418/tox7bul.pdf
Helpful?
-
-
I'm using the TOX7 In Vitro Toxicology Assay Kit. I do not have a 690 nm filter to use for a reference/background. What can I use?
1 answer-
The reference wavelength needs to be greater than the absorbance spectra of the assay. The greater the difference between the assay wavelength and the reference wavelength, the better. A reference wavelength of 590 nm or greater can be used with the substrate for this assay. If a reference wavelength is not available, the assay will work. The use of the reference wavelength increases the signal to noise ratio to give a better assay range.
Helpful?
-
-
Will Triton X100 interfere with the TOX7 In Vitro Toxicology Kit assay?
1 answer-
Triton X100 will not interfere with TOX7 assay.
Helpful?
-
-
Can TOX7, In Vitro Toxicology Assay kit be used to quantitate the amount of LDH in my samples?
1 answer-
This assay kit was designed as a semi-quantitative assay for LDH. The change in the OD between the treated samples and control samples is to be compared and is generally reported as a fold increase/decrease from the control. The kit does not contain a LDH standard. Product L3916 can be used as an LDH standard for this assay. The detection range (LDH units/ml) for the kit has not been established.
Helpful?
-
-
I am using a protease inhibitor cocktail in the cell culture media. Will this interfere with the TOX7 In Vitro Toxicology assay?
1 answer-
The protease inhibitor cocktails do not interfere with LDH activity. Media from cells cultured with protease inhibitors can be used in this assay.
Helpful?
-
-
The TOX7 dye solution has a precipitate present. Can I still use it?
1 answer-
Product No. L2277 LDH Assay Dye Solution is a saturated solution and some precipitation may appear upon thawing. The product will partially re-solubilize when warmed to 37°C and the resulting solution can be decanted away from any remaining precipitate. Precipitated dye added to reactions, or removed from the solution will not affect the performance or results obtained from this kit.
Helpful?
-
-
What is the minimum number of cells to use in the LDH assay, Product TOX7, In Vitro Toxicology Assay Kit?
1 answer-
Using Product TOX7, In Vitro Toxicology Assay Kit, the minimum cell number for best response is 2 x 104.
Helpful?
-
-
Can you use tissue explants in product TOX7, In Vitro Toxicology Assay Kit, Lactic Dehydrogenase based?
1 answer-
Unfortunately, we have not tested product TOX7, In Vitro Toxicology Assay Kit, on tissue samples. If the tissue is minced well and can be lysed completely with the lysis buffer for the cells, it may work to determine cell biomass. The following paper modified the assay for use with explants.Benyo, D.F., et al., "Hypoxia Stimulates Cytokine Production by Villous Explants from the Human Placenta", The Journal of Clinical Endocrinology & Metabolism 82(5), 1582-1588 (1997).Assessment of explant viability was routinely monitored by measuring the release of LDH into medium relative to a 1% Triton X-100 (Sigma)-lysed positive control. The assay employed a modification of the TOX7 viability kit supplied by Sigma-Aldrich and entailed adding a 20-fold volume excess of assay mixture (160 mL) to the medium sample tested (8 mL). The assay mixture consisted of equal volumes of substrate (lactate), enzyme (diaphorase), and dye (nitro blue tetrazolium) solutions, and the reaction was allowed to proceed for 20 min in a microtiter plate before the addition of 0.1 vol 1N HCl. Color change was quantified by reading the absorbance at 490 nm, and the percent cell death calculated.
Helpful?
-
-
What is the Department of Transportation shipping information for this product?
1 answer-