Skip to Content
Merck

Skip To

1.16127

Lactic Acid Test Strips, reflectometric

3.0-60.0 mg/L (lactic acid), REFLECTOQUANT®, for use with RQflex® 20

Synonym(s):

Lactic Acid chemical test strips, Lactic Acid test strip for instrument reader

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Size/SKUAvailabilityPrice
50 tests
Please contact Customer Service for Availability
4 000,00 CZK

About This Item

UNSPSC Code:
41116116
NACRES:
NA.24
eCl@ss:
40050204

4 000,00 CZK


Please contact Customer Service for Availability

​
Request a Custom OrderRequest more information
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


Product Name

Lactic Acid Test, reflectometric, 3.0-60.0 mg/L (lactic acid), for use with REFLECTOQUANT®

description

quantitative

Quality Segment

specific analyte(s)

lactic acid

reaction suitability

reaction type: enzymatic reaction

measuring range

3.0-60.0 mg/L (lactic acid)

application(s)

beverage testing
cannabis testing
food testing
milk and dairy products

compatibility

RQflex® 20, for use with REFLECTOQUANT®

detection method

reflectometric

storage temp.

2-8°C

General description

Method: reflectometric with test strips 3.0 - 60.0 mg/l Reflectoquant®
The Reflectoquant Lactic acid test measures total lactic acid (sum of D- and L-lactic acid in beverages, e.g. wine, beer and fruit/vegetable juice after dilution. Furthermore the test can be used for the determination of lactic acid in food after pretreatment. Lactic acid (lactate) is oxidized by nicotinamide adenine dinucleotide (NAD) under the catalytic effect of lactate dehydrogenase to a pyruvate. In the presence of diaphorase, the NADH formed in the process reduces a tetrazolium salt to a blue formazan that is determined reflectometrically on the RQflex® 20.

Analysis Note

function control: entspricht
Assay
- standard 1:
4.5 - 5.5 mg/l
- standard 2: 22.5 - 27.5 mg/l
- standard 3: 45.0 - 55.0 mg/l

Legal Information

REFLECTOQUANT is a registered trademark of Merck KGaA, Darmstadt, Germany
RQFLEX is a registered trademark of Merck KGaA, Darmstadt, Germany


Storage Class

11 - Combustible Solids

WGK

WGK 2


Regulatory Listings

Regulatory Listings are mainly provided for chemical products. Only limited information can be provided here for non-chemical products. No entry means none of the components are listed. It is the user’s obligation to ensure the safe and legal use of the product.

7783-20-2

CAS No.


Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documents section.

If you need assistance, please contact Customer Support

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library



Questions

1–3 of 3 Questions  
  1. According to the User Guide, Fruit Juices have to be diluted. What's the recommended dilution factor for Orange Juice, Pineapple Juice, Grapefruit Juice etc. Is there an application note available for fruit juices?

    1 answer
    1. Vegetable and fruit juices, including orange, pineapple, and grapefruit juices, should be diluted at a ratio of 1:50. This information is provided in the User Guide for product 1.16127 on the product description page.

      Helpful?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  3. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters