Skip to Content
Merck

Skip To

NA0200

GenElute™ HP Plasmid Midiprep Kit

sufficient for 25 purifications

Sustainability features

Synonym(s):

GenElute™ HP Plasmid Midiprep Kit, plasmid extraction kit, plasmid isolation kit, plasmid purification kit, Gen Elute

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Size/SKUAvailabilityPrice
1 kit
Please contact Customer Service for Availability
12 300,00 CZK

About This Item

NACRES:
NA.52
UNSPSC Code:
41105501

12 300,00 CZK


Please contact Customer Service for Availability

​
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


usage

sufficient for 25 purifications

Quality Segment

sustainability

Sustainability features

technique(s)

DNA purification: suitable

test parameters

sample volume: 1-5 mL bacterial culture

greener alternative category

storage temp.

15-25°C

General description

This product aligns with one or more of the 12 Principles of Green ChemistryThis product has Inherently Safer Chemistry, compared to the standard use of phenol and chloroform to perform DNA extractions.
The GenElute HP Plasmid Midiprep Purification kits offer an ultrafast and efficient solution for large-scale plasmid preparation from E. coli cultures. These kits combine silica-based membrane technology and the convenience of spin or vacuum format. The kits also include a special filter cartridge, which replaces the centrifugation step following alkaline lysis. Following lysis the DNA is bound to the silica membrane and contaminants are removed with a simple wash step. The DNA is then eluted in water or TE buffer by centrifugation.

The purified plasmid DNA is suitable for a wide variety of molecular biology applications, including restriction digestions and sequencing.

Application

GenElute™ HP Plasmid Midiprep Kit has been used to isolate and purify plasmids.

Features and Benefits

  • From harvested bacterial culture to pure plasmid DNA in 30 minutes or less
  • Up to 350 μg of high-copy plasmid DNA
  • Flexibility of a vacuum or spin format
  • No phenol/chloroform extraction or alcohol precipitation required
  • Contains fewer plastic components, reducing the amount of waste

Other Notes

For additional information, please see www.sigma-aldrich.com/genelutehp.

Legal Information

GenElute is a trademark of Sigma-Aldrich Co. LLC

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
PLED35PLD35NA0160
description

sufficient for 25 purifications

description

sufficient for 35 purifications

description

sufficient for 35 purifications

description

sufficient for 350 preparations

technique(s)

DNA purification: suitable

technique(s)

DNA purification: suitable

technique(s)

DNA purification: suitable

technique(s)

DNA extraction: suitable

usage

sufficient for 25 purifications

usage

sufficient for 35 purifications

usage

sufficient for 35 purifications

usage

sufficient for 350 preparations

greener alternative category

greener alternative category

greener alternative category

greener alternative category

greener alternative product characteristics

Designing Safer Chemicals
Learn more about the Principles of Green Chemistry.

greener alternative product characteristics

Inherently Safer Chemistry for Accident Prevention
Learn more about the Principles of Green Chemistry.

greener alternative product characteristics

Inherently Safer Chemistry for Accident Prevention
Learn more about the Principles of Green Chemistry.

greener alternative product characteristics

Designing Safer Chemicals
Learn more about the Principles of Green Chemistry.

Quality Level

200

Quality Level

200

Quality Level

200

Quality Level

200

test parameters

sample volume: 1-5 mL bacterial culture

test parameters

: <2 hr kit run time for up to 12 preps, sample volume: 25-200 mL bacterial culture

test parameters

: ~45 min kit run time, sample volume: 5-40 mL bacterial culture

test parameters

: <30 min kit run time, sample volume: 1-5 mL bacterial culture


Signal Word

Danger

Target Organs

Central nervous system

Storage Class

3 - Flammable liquids

WGK

WGK 3

Hazard Classifications

Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Dam. 1 - Flam. Liq. 3 - Met. Corr. 1 - Resp. Sens. 1 - Skin Corr. 1B - STOT SE 3



Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documents section.

If you need assistance, please contact Customer Support

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library




Questions

1–6 of 6 Questions  
  1. Do the binding columns fit on other manufacturers’ manifolds?

    1 answer
    1. Yes. The columns fit on all standard vacuum manifolds.

      Helpful?

  2. Is plasmid DNA isolated with this kit suitable for use in transfection?

    1 answer
    1. Yes. However, if you are currently required to use an endofree plasmid purification kit, we recommend using the GenElute HP Endotoxin-free Kit.

      Helpful?

  3. How long does it take to isolate plasmid using the vacuum format?

    1 answer
    1. A midiprep or maxiprep requires only 30 minutes to complete.

      Helpful?

  4. What is the expected yield of plasmid DNA that you can isolate from these kits?

    1 answer
    1. Yields can reach as high as 350 mg for a midiprep and 1.2 mg for a maxiprep. As with any protocol, lower yields can be expected with low copy plasmids.

      Helpful?

  5. How do the GenElute HP Plasmid Kits differ from other plasmid purification systems?

    1 answer
    1. The GenElute HP Plasmid Kits are much faster than other commercially available kits. A filter syringe is used for preparing the cleared lysate, which replaces a lengthy centrifugation step. These kits also offer the option of using a vacuum or spin purification format rather than a gravity drip to bind, wash and elute the plasmid. In addition, samples are eluted in Tris buffer so there are no alcohol precipitations required.

      Helpful?

  6. Which format gives a better yield, vacuum or spin?

    1 answer
    1. There is no difference in plasmid recovery when using either format.

      Helpful?

Reviews

No rating value

Active Filters