Skip to Content
Merck
  • Polyethylene glycol modified magnetic carbon nanotubes as nanosorbents for the determination of methylprednisolone in rat plasma by high performance liquid chromatography.

Polyethylene glycol modified magnetic carbon nanotubes as nanosorbents for the determination of methylprednisolone in rat plasma by high performance liquid chromatography.

Journal of chromatography. A (2014-05-20)
Panfeng Yu, Hongwei Ma, Yong Shang, Ji Wu, Shun Shen
ABSTRACT

In this paper, polyethylene glycol modified (PEGylated) magnetic carbon nanotubes were developed as solid-phase extraction nanosorbents for the determination of methylprednisolone in rat plasma. The procedure mainly involved two steps including preparation of PEGylated magnetic nanosorbents and bioanalysis. Monodisperse magnetites (Fe3O4) anchored onto multi-walled carbon nanotubes (MWCNTs) were synthesized by a facile solvothermal synthesis method. The obtained MWCNTs-Fe3O4 nanomaterials were further non-covalently functionalized by a surfactant phospholipids-polyethylene glycol (DSPE-PEG). Owing to dispersibility and high enrichment ability, water-soluble PEGylated MWCNTs-Fe3O4 nanomaterials can provide more efficient way for the extraction of methylprednisolone than only MWCNTs-Fe3O4 used. The methylprednisolone could be easily extracted via π-π stacking interactions with PEGylated MWCNTs-Fe3O4. The captured methylprednisolone/nanosorbents were isolated from the matrix by placing a magnet, and desorbed by the elution solvent composed of acetonitrile. Extraction conditions such as amount of nanosorbents added, adsorption time, desorption solvent, and desorption time were investigated and optimized. The method recoveries were obtained from 88.2% to 92.9%. Limits of quantification and limits of detection of 0.01 and 0.005μg/mL were acquired, respectively. The precision ranged from 4.2% to 7.8% for within-day measurement, and for between-day variation was in the range of 5.5-9.0%. Moreover, the analytical performance obtained by PEGylated magnetic MWCNTs was compared with that of magnetic MWCNTs. The results indicated that the approach based on PEGylated magnetic MWCNTs was useful for the analysis of methylprednisolone in the complex plasma.

MATERIALS
Product Number
Brand
Product Description

Supelco
L-Lysine monohydrochloride, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
L-Lysine monohydrochloride, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
Sigma-Aldrich
Ethylene glycol 5 M solution
Sigma-Aldrich
L-Lysine monohydrochloride, from non-animal source, meets EP, JP, USP testing specifications, suitable for cell culture, 98.5-101.0%
Sigma-Aldrich
L-Lysine monohydrochloride, reagent grade, ≥98% (HPLC)
Supelco
L-Lysine hydrochloride solution, 100 mM amino acid in 0.1 M HCl, analytical standard
Sigma-Aldrich
L-Lysine monohydrochloride, BioUltra, ≥99.5% (AT)
Sigma-Aldrich
Dexamethasone, powder, γ-irradiated, BioXtra, suitable for cell culture, ≥80% (HPLC)
Sigma-Aldrich
Dexamethasone, powder, BioReagent, suitable for cell culture, ≥97%
Sigma-Aldrich
Dexamethasone, tested according to Ph. Eur.
Supelco
Acetonitrile, analytical standard
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Supelco
Dexamethasone, VETRANAL®, analytical standard
Supelco
Hexane, analytical standard
Sigma-Aldrich
6α-Methylprednisolone, ≥98%
Sigma-Aldrich
Dexamethasone, meets USP testing specifications
Sigma-Aldrich
Dexamethasone, ≥98% (HPLC), powder
Supelco
Dexamethasone, Pharmaceutical Secondary Standard; Certified Reference Material
Dexamethasone for system suitability, European Pharmacopoeia (EP) Reference Standard
USP
Dexamethasone, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Hexane, ReagentPlus®, ≥99%
Sigma-Aldrich
Hexane, HPLC Plus, for HPLC, GC, and residue analysis, ≥95%
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acetonitrile, ReagentPlus®, 99%
Sigma-Aldrich
Acetonitrile, HPLC Plus, ≥99.9%
Sigma-Aldrich
Acetonitrile, ACS reagent, ≥99.5%
Dexamethasone, European Pharmacopoeia (EP) Reference Standard
USP
Methyl alcohol, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Hexane, suitable for HPLC, ≥95%