Skip to Content
Merck
  • Liquid chromatography tandem mass spectrometry determination of selected synthetic cathinones and two piperazines in oral fluid. Cross reactivity study with an on-site immunoassay device.

Liquid chromatography tandem mass spectrometry determination of selected synthetic cathinones and two piperazines in oral fluid. Cross reactivity study with an on-site immunoassay device.

Journal of chromatography. A (2014-12-09)
Ana de Castro, Elena Lendoiro, Hadriana Fernández-Vega, Stefan Steinmeyer, Manuel López-Rivadulla, Angelines Cruz
ABSTRACT

Since the past few years, several synthetic cathinones and piperazines have been introduced into the drug market to substitute illegal stimulant drugs such as amphetamine and derivatives or cocaine due to their unregulated situation. These emerging drugs are not usually included in routine toxicological analysis. We developed and validated a LC-MS/MS method for the determination of methedrone, methylone, mephedrone, 3,4-methylenedioxypyrovalerone (MDPV), fluoromethcathinone, fluoromethamphetamine, 1-(3-chlorophenyl)piperazine (mCPP) and 3-trifluoromethylphenylpiperazine (TFMPP) in oral fluid. Sample extraction was performed using Strata X cartridges. Chromatographic separation was achieved in 10min using an Atlantis(®) T3 column (100mm×2.1mm, 3μm), and formic acid 0.1% and acetonitrile as mobile phase. The method was satisfactorily validated, including selectivity, linearity (0.2-0.5 to 200ng/mL), limits of detection (0.025-0.1ng/mL) and quantification (0.2-0.5ng/mL), imprecision and accuracy in neat oral fluid (%CV=0.0-12.7% and 84.8-103.6% of target concentration, respectively) and in oral fluid mixed with Quantisal™ buffer (%CV=7.2-10.3% and 80.2-106.5% of target concentration, respectively), matrix effect in neat oral fluid (-11.6 to 399.7%) and in oral fluid with Quantisal™ buffer (-69.9 to 131.2%), extraction recovery (87.9-134.3%) and recovery from the Quantisal™ (79.6-107.7%), dilution integrity (75-99% of target concentration) and stability at different conditions (-14.8 to 30.8% loss). In addition, cross reactivity produced by the studied synthetic cathinones in oral fluid using the Dräger DrugTest 5000 was assessed. All the analytes produced a methamphetamine positive result at high concentrations (100 or 10μg/mL), and fluoromethamphetamine also at low concentration (0.075μg/mL).

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
2-Propanol, Laboratory Reagent, ≥99.5%
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acetonitrile, ReagentPlus®, 99%
Sigma-Aldrich
Dichloromethane, ACS reagent, ≥99.5%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
Dichloromethane, ACS reagent, ≥99.5%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
Acetonitrile, ACS reagent, ≥99.5%
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
USP
2-Propanol, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
2-Propanol, ACS reagent, ≥99.5%
Sigma-Aldrich
Dichloromethane, contains 40-150 ppm amylene as stabilizer, ACS reagent, ≥99.5%
Sigma-Aldrich
Sodium hydroxide-16O solution, 20 wt. % in H216O, 99.9 atom % 16O
Sigma-Aldrich
Boric acid, 99.97% trace metals basis
Sigma-Aldrich
Boric acid, BioUltra, Molecular Biology, ≥99.5% (T)
Sigma-Aldrich
Dichloromethane, HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%, contains 50-150 ppm amylene as stabilizer
Sigma-Aldrich
2-Propanol, suitable for HPLC, 99.5%
Sigma-Aldrich
2-Propanol, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
2-Propanol, HPLC Plus, for HPLC, GC, and residue analysis, 99.9%, poly coated bottles
Sigma-Aldrich
Isopropyl alcohol, meets USP testing specifications
Sigma-Aldrich
2-Propanol, puriss. p.a., ACS reagent, ≥99.8% (GC)
Sigma-Aldrich
2-Propanol, BioReagent, ≥99.5%, Molecular Biology
Sigma-Aldrich
2-Propanol, BioUltra, Molecular Biology, ≥99.5% (GC)
Supelco
2-Propanol, analytical standard
Sigma-Aldrich
2-Propanol, HPLC Plus, for HPLC, GC, and residue analysis, 99.9%
Supelco
2-Propanol, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
2-Propanol, suitable for HPLC, 99.9%
USP
Residual Solvent Class 2 - Acetonitrile, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Boric acid, BioXtra, ≥99.5%
Sigma-Aldrich
Boric acid, suitable for electrophoresis, ≥99.5%
Supelco
Acetonitrile, analytical standard