Skip to Content
Merck

ICS045

Formaldehyde Standard

certified reference material

Sign In to View Organizational & Contract Pricing.

Select a Size

Pricing and availability is not currently available.

About This Item

NACRES:
NA.24
UNSPSC Code:
41116107

Skip To

Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist

Product Name

Formaldehyde Standard, certified reference material

grade

certified reference material

CofA

current certificate can be downloaded

manufacturer/tradename

RTC ICS-045-100

concentration

1000 μg/mL in H2O

technique(s)

ion chromatography: suitable

application(s)

environmental
food and beverages

format

single component solution

storage temp.

2-30°C

Quality Level

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
QC1380ICS012ICS023
technique(s)

ion chromatography: suitable

technique(s)

HPLC: suitable, gas chromatography (GC): suitable

technique(s)

ion chromatography: suitable

technique(s)

ion chromatography: suitable

application(s)

environmental
food and beverages

application(s)

environmental
food and beverages

application(s)

environmental
food and beverages

application(s)

environmental
food and beverages

format

single component solution

format

matrix material

format

single component solution

format

single component solution

Quality Level

300

Quality Level

300

Quality Level

100, 300

Quality Level

300

grade

certified reference material

grade

certified reference material

grade

analytical standard

grade

analytical standard, certified reference material

storage temp.

2-30°C

storage temp.

2-8°C

storage temp.

2-8°C

storage temp.

2-8°C

General description

This Certified Reference Material (CRM) is produced and certified in accordance with ISO 17034 and ISO/IEC 17025. All information regarding the use of this CRM can be found on the certificate of analysis.

Other Notes

Values of analytes vary lot to lot. Some lots may not contain all analytes.

pictograms

Health hazard

signalword

Danger

hcodes

Hazard Classifications

Carc. 1B

Storage Class

6.1D - Non-combustible acute toxic Cat.3 / toxic hazardous materials or hazardous materials causing chronic effects

wgk

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Questions

1–6 of 6 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  3. Does this product already contain 2,4-DNPH or has 2,4-DNPH only been added to the product for CoA testing?

    1 answer
    1. This product does not contain 2,4-Dinitrophenylhydrazine (2,4 DNPH). (2,4 DNPH) was used as a derivatizing agent for QC analysis.

      Helpful?

  4. Does Product ICS045 contain methanol as a stabilizer?

    1 answer
    1. This product does have methanol in it

      Helpful?

  5. The CoA for the lot purchased lists the raw material potency as 35.2%, what is the purpose of this value? If I want to make a calibration curve using this, do I need to take this number into account? Or am I just using the 1000 mg/L for calculations?

    1 answer
    1. Raw material purity is included for traceability to the raw material. In some cases, it can also explain any low-level impurities that a customer might see in the provided chromatogram. Please use the certified value directly. No correction of the certified value is needed. It has already been corrected for the raw material purity.

      Helpful?

  6. hola, con respecto al producto ICS045, me gustaría saber que concentración tiene de formaldehído, puesto que en la información del producto pone 1000ug/ml y en el certificado de origen de ejemplo que se puede descargar, pone 1000mg/l.

    1 answer
    1. As listed in the properties section on the website, the concentration is 1000 μg/mL in H2O. The 1000 μg/mL may be converted to 1 mg/mL. Thus, the 1000mg/L reported in the Certificate is also correct.

      Helpful?

Reviews

No rating value

Active Filters

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service