Seleccione un Tamaño
| Talla/SKU | Disponibilidad | Precio |
|---|---|---|
10 g | Póngase en contacto con nuestro Servicio de Atención al Cliente para disponibilidad | 2380,00 € |
Acerca de este artículo
2380,00 €
Nombre del producto
Superspher® 100 RP-18,
material
stainless steel column
agency
suitable for USP L1
product line
Superspher®
feature
endcapped: no
analyte functional class(es)
antibiotics, explosives, fat soluble vitamins, lipids, nutraceuticals and antioxidants, oils, pigments, sweeteners, water soluble vitamins
analyte chemical class(es)
PAHs, PCBs (aroclor identification), PFAS, aflatoxins, alcohols / fermentation, alcohols and aldehyde, aliphatic amines, alkaloids, amino acids, aromatic amines, cannabinoids as tms derivatives, carotenoids, catecholamines, coloring compounds, essential oils, esters, fatty acids, flavonoids, glycans, ketones, metabolized steroids, nitrosamines, nucleic acids, nucleosides, oligonucleotides, organic phosphates, peptides, pesticides, phenols, phospholipids, phthalate esters, preservatives, proteins, steroids (cholesteryl esters), sulfonamides
manufacturer/tradename
Millipore
parameter
60 °C max. temp.
technique(s)
HPLC: suitable, mass spectrometry (MS): suitable (Low - Medium)
matrix
fully porous particle
matrix active group
C18 (RP18), C18 bonding phase
particle size
4 μm
pore size
100 Å pore size
operating pH range
2-7.5
bulk density
200‑400 kg/m3
separation technique
reversed phase
storage temp.
no temp limit
General description
Application
- Determination of retinol and retinyl esters in human plasma: This study utilized high-performance liquid chromatography with automated column switching and ultraviolet detection, highlighting the utility of the Superspher 100 RP-18 HPLC column in sensitive biochemical analyses (Hartmann et al., 2001).
- Enantioselective assay for ketoprofen glucuronidation: This study underscores the column′s capability in pharmacokinetic research, using HPLC to analyze chiral anti-inflammatory drugs and their metabolites in liver microsomes (Chakir et al., 1994).
- Rapid liquid chromatographic assay of glutathione in cultured cells: Employing the Superspher 100 RP-18 column, this research focused on rapid and effective glutathione quantification, demonstrating the column′s versatility in biomedicine (Leroy et al., 1993).
- Assay of chloramphenicol acetyl transferase by high-performance liquid chromatography: This application further exemplifies the adaptability of Superspher® 100 RP-18 in biotechnology, offering precise measurement techniques for enzymatic activity studies (Burzio et al., 1988).
Analysis Note
Pressure: 50 - 70 bar
Theoretical Plates (N/m) (Anthracene): ≥ 105000
Symmetry (Anthracene): 0.8 - 1.4
Capacity factor (Anthracene): 4.0 - 5.5
separation factor (Acetophenone/Phenol, selectivity test): 1.90 - 2.15
separation factor (Acetophenone/Cinnamic acid, selectivity test): 1.20 - 1.37
separation factor (1-Naphtol/Phenol, selectivity test): 3.80 - 4.30
capacity factor (Toluene): 17.0 - 22.0
Legal Information
Clase de almacenamiento
11 - Combustible Solids
WGK
nwg
Punto de inflamación (°F)
Not applicable
Punto de inflamación (°C)
Not applicable
Elija entre una de las versiones más recientes:
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.